{"product_id":"celera-incoder-inc-3-075-ssi1","title":"Celera Motion IncOder INC-3-075 SSI1 Inductive Ring Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for IncOder INC-3-075 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Celera Motion IncOder INC-3-075 SSI1 Inductive Ring Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA compatible SSI receiver or scope can check frame timing and count repeatability with the correct mount, cable and supply. Record validity before adjusting mechanics. Confirm exact Mitchell profile and adapter compatibility if considering that equipment.\u003c\/p\u003e\n\u003ch2\u003eCelera Motion IncOder INC-3-075 SSI1 Inductive Ring Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eINC-3-075-181001-SSI1-AC1-12-AN\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eINC-3-075-181001-SSI1-AC1-12-AN\u003c\/th\u003e\n\u003ctd\u003e75 mm screw-mount rotor and stator, hard-anodized. AC1 axial connection.\u003c\/td\u003e\n\u003ctd\u003e18-bit resolution, SSI1, nominal 12 V option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eINC-4-90-191001-ASI1-RFC1-24-AN\u003c\/th\u003e\n\u003ctd\u003ePublished 90 mm servo-clamp example with radial flex connection.\u003c\/td\u003e\n\u003ctd\u003eSeparate asynchronous serial and 24 V configuration. Verify the actual label.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSSI2 configuration\u003c\/th\u003e\n\u003ctd\u003eSelect the mechanical and supply options separately.\u003c\/td\u003e\n\u003ctd\u003eSSI2 frame differs from SSI1. Check the receiver frame definition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for INC-3-075-181001-SSI1-AC1-12-AN\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for INC-3-075-181001-SSI1-AC1-12-AN\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrder code\u003c\/th\u003e\n\u003ctd\u003eINC-3 screw mount, 075 diameter, 18-bit reference configuration, SSI1, AC1, 12 V, AN finish.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition\u003c\/th\u003e\n\u003ctd\u003e18-bit singleturn value in the documented SSI1 frame. Use its validity and status bits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eSet rotor\/stator spacing and alignment per the 75 mm screw-mount drawing. Match the exact mechanical option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003eDifferential RS-422 clock input and data output. The reference example selects the 12 V supply option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.celeramotion.com\/inductive-sensors\/wp-content\/uploads\/sites\/7\/2019\/05\/IncOder-Product-Guide_MIDI_Rev_4.11.5.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe shaft turns the ring rotor while the stator remains fixed to the machine. Use the 75 mm screw-mount drawing for the pilot, fasteners and allowable rotor-to-stator geometry. Check axial movement at the extremes of service travel. Confirm the assembly has clearance and the cable is supported before rotating.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe receiver initiates each SSI read with differential clock pulses. SSI1 sends a binary position field with status in a 24-bit frame. The 18-bit device fills the applicable position bits. The receiver must check position validity and use the proper field and frame length before applying machine scale or offset.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThe table identifies contacts for the documented SSI1-compatible INC-CAB3 cable in section 9.1. Use the AC1 connector face drawing before terminating a lead.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"IncOder SSI1 cable assignment\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eIncOder SSI1 cable assignment\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eConnector contact\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply \/ return\u003c\/th\u003e\n\u003ctd\u003e10 \/ 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eData A \/ B\u003c\/th\u003e\n\u003ctd\u003e5 \/ 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClock A \/ B\u003c\/th\u003e\n\u003ctd\u003e8 \/ 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZero controls\u003c\/th\u003e\n\u003ctd\u003eUse section 7.1 for the exact reset and set circuit. Keep the factory state during diagnosis.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eSeveral wires are black in the factory cable. Identify them by their pair and verified continuity. Use the 12 V option's documented supply limits and the specified shielding and termination.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eINC-CAB3-2, INC-CAB3-5 and INC-CAB3-10 are the 2, 5 and 10 m standard 8-way cable options in the product guide. The manufacturer lists separate HT variants. Confirm the installed connector, receiver end and temperature conditions.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo valid position\u003c\/th\u003e\n\u003ctd\u003eConfirm clock and data pairs, the exact power option and SSI1 frame settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValidity drops at one shaft angle\u003c\/th\u003e\n\u003ctd\u003eCheck concentricity and rotor\/stator spacing across a full controlled turn.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSmooth count but wrong engineering angle\u003c\/th\u003e\n\u003ctd\u003eVerify scaling, zero offset and SSI1 position field before moving the rotor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse on machine axes with a compatible SSI receiver. Confirm the installed ring dimensions, drive input and machine-reference method. The documented example identifies a valid configuration. Verify orderability for the exact code.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSet mechanical alignment using the matching drawing. Record the original SSI direction and zero before replacing parts. If a zero command is required, follow the manufacturer and machine procedure and verify the reported angle across motion.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.celeramotion.com\/inductive-sensors\/wp-content\/uploads\/sites\/7\/2019\/05\/IncOder-Product-Guide_MIDI_Rev_4.11.5.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.celeramotion.com\/inductive-sensors\/wp-content\/uploads\/sites\/7\/2019\/05\/IncOder-Product-Guide_MIDI_Rev_4.11.5.pdf\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.celeramotion.com\/inductive-sensors\/wp-content\/uploads\/sites\/7\/2019\/05\/IncOder-Product-Guide_MIDI_Rev_4.11.5.pdf\"\u003eMounting and connection reference\u003c\/a\u003e. Use the 75 mm drawing, SSI1 in section 6.4, AC1 in section 7.1, and cables in section 9.1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Celera Motion Inc","offers":[{"title":"Default Title","offer_id":51119294054565,"sku":"TCG77","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/CeleraMotionIncOderINC-3-075SSI1InductiveRingEncoder.jpg?v=1794158440","url":"https:\/\/www.sparefaber.com\/de\/products\/celera-incoder-inc-3-075-ssi1","provider":"SpareFaber","version":"1.0","type":"link"}