{"product_id":"control-techniques-unimotor-fm-ec-fc-endat21-feedback","title":"Control Techniques Unimotor fm EC \/ FC EnDat 2.1 Servo Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eRead EC or FC on the complete Unimotor fm order. The Control Techniques table maps EC to EQI 1331 multiturn and FC to ECI 1319 singleturn.\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE on-site fault diagnosis, installation and alignment checks for the documented feedback. Send the fitted labels and alarm details to arrange a visit or a send-in evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Control Techniques Unimotor fm EC \/ FC EnDat 2.1 Servo Feedback technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Read absolute data and verify the separate analogue tracks where present.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Confirm the full motor order, power lead, phase reference and supported TI-3000JX setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e TI-5690 on the documented 17-contact M23 EnDat branch. Check the actual EC\/FC drawing.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eControl Techniques Unimotor fm EC \/ FC EnDat 2.1 Servo Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnimotor fm EC \/ FC\u003c\/th\u003e\n\u003ctd\u003eEC is EQI 1331 multiturn. FC is ECI 1319 singleturn. Confirm the motor and exact encoder ID.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEF \/ FF and GB \/ HB\u003c\/th\u003e\n\u003ctd\u003eThe cited OEM table lists separate EnDat22 options. Match the connector and drive.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCT-Coder\u003c\/th\u003e\n\u003ctd\u003eSeparate feedback selection with its own setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial interface\u003c\/th\u003e\n\u003ctd\u003eEnDat 2.1 \/ EnDat 01 for EC and FC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue tracks\u003c\/th\u003e\n\u003ctd\u003e32 sine\/cosine periods per turn in the cited EC\/FC table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback supply\u003c\/th\u003e\n\u003ctd\u003e4.75–10 V DC for the documented options. Use the approved motor-side connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTurn field\u003c\/th\u003e\n\u003ctd\u003eEC has 4,096 turns in the cited table. FC is singleturn.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe drive reads position through EnDat and uses the analogue tracks where required. Assess serial position, the turn format and analogue movement independently.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the actual frame and fitted encoder drawing. Check the locating seat, rotor fastening and specified sensing gap. Record the cable exit and received reference.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eThe contact groups below apply to the manufacturer’s 17-contact SI motor-end EC\/FC column. Confirm the connector drawing and viewing side before wiring.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Connection reference for the stated view\" tabindex=\"0\"\u003e\u003ctable id=\"wiring-table\"\u003e\n\u003ccaption\u003eConnection reference for the stated view\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eContact or circuit\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1 and 2\u003c\/th\u003e\n\u003ctd\u003eThermistor pair.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8 \/ 9\u003c\/th\u003e\n\u003ctd\u003eClock + \/ −.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e11 \/ 12\u003c\/th\u003e\n\u003ctd\u003eData + \/ −.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e10 \/ 13\u003c\/th\u003e\n\u003ctd\u003eCosine + \/ −.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e14 \/ 15\u003c\/th\u003e\n\u003ctd\u003eSine + \/ −.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e16 \/ 17\u003c\/th\u003e\n\u003ctd\u003eFeedback supply \/ 0 V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnector body\u003c\/th\u003e\n\u003ctd\u003eScreen. Follow the applicable wiring figure for shield termination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eUse the OEM SI cable order key and drive type for the production assembly. Record the internal encoder lead separately from the TI-5690 test fixture.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eUse only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial position present, analogue fault\u003c\/th\u003e\n\u003ctd\u003eTrace the documented sine and cosine pairs separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnexpected turn count\u003c\/th\u003e\n\u003ctd\u003eCompare EC and FC and confirm drive format.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo response after cable change\u003c\/th\u003e\n\u003ctd\u003eCheck the SI connector view, supply and clock\/data pairs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSave the original motor reference and direction and any position data needed by the drive. Verify the fitted encoder and phase convention before commissioning.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUnimotor fm with EC or FC and the documented 17-contact M23\u003c\/p\u003e\n\u003cp\u003eChoose EC versus FC and distinguish EnDat 2.1 from EnDat 2.2-only and CT-Coder options.\u003c\/p\u003e\n\u003ch3\u003eRelated SpareFaber guides\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/de\/products\/control-techniques-ct-coder-slm3-feedback\"\u003eControl Techniques CT-Coder + SLM3 SL Motor Feedback\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\"\u003eMitchell Test Cable Index by Manufacturer Support\u003c\/a\u003e. Control Techniques Support Part Numbers, TI-5690. OEM Unimotor fm EC\/FC motor-end signal table.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/moen.nidec.com\/drives\/-\/media\/Project\/Nidec\/ControlTechniques\/Documents\/en-en\/CTD\/Brochures\/Unimotor-FM-3-brochure.pdf\"\u003eControl Techniques Unimotor fm, feedback order and pin tables\u003c\/a\u003e. Supplementary reference for the stated model or setup.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51134760485029,"sku":"TCG374","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/control-techniques-unimotor-fm-ec-fc-endat21-feedback-service-guide.jpg?v=1794303223","url":"https:\/\/www.sparefaber.com\/de\/products\/control-techniques-unimotor-fm-ec-fc-endat21-feedback","provider":"SpareFaber","version":"1.0","type":"link"}