{"product_id":"dynapar-rim-tach-8500-rt8","title":"Dynapar NorthStar NexGen RIM Tach 8500 RT8 Encoder  | Technical Guide| Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eLost speed feedback on a NorthStar RIM Tach?\u003c\/strong\u003e SpareFaber can visit your UAE site to inspect the C-face mount, target wheel, sensor module, cable and drive input. Ask about bench checks of a matching sensor and wheel assembly.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Dynapar NorthStar NexGen RIM Tach 8500 RT8 Encoder technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the housing and module labels, PPR, wheel code, photos of the connector and motor face, drive model and the speed at which pulses drop out. Note whether a sensor or wheel was replaced recently. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA guarded fixture with the correct wheel and sensor lets a technician check differential A\/B, count and direction, optional Z and the available alarm. Compare both outputs on a dual-channel build using the documented isolated supplies and receiver inputs. Mitchell describes a \u003cstrong\u003eTI-5000JX Generic Incremental Encoder\u003c\/strong\u003e test method. Use a documented adapter or receiver matched to the RT8 signal levels before connecting. Standalone RT8 compatibility and an RT8-specific TI-3000JX run profile require confirmation. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26564715015195-Generic-Incremental-Quadrature-Pulse-Encoders\"\u003eMitchell generic quadrature test method\u003c\/a\u003e · \u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/NexGen_RT8500_IM_702869_1_D.pdf#page=1\"\u003eDynapar electrical ratings (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eDynapar NorthStar NexGen RIM Tach 8500 RT8 Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eRecord the full RT8 number and the installed wheel and sensor module labels. Page 8 of the installation manual decodes PPR, index, wheel size or end-of-shaft adapter, single or dual output and termination. The word 8500 appears on both legacy and NexGen material.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Exact RT8 examples and the legacy family\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eExact RT8 examples and the legacy family\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eName or full order number\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePulses and index\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWheel \/ connector\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRT81024LF082Q\u003c\/th\u003e\n\u003ctd\u003e1024 PPR. L means no index. Code 2 specifies dual output.\u003c\/td\u003e\n\u003ctd\u003eF08 end-of-shaft 2⅜ in configuration. Q denotes latching connector on an 18 in cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRT82048ZV071C\u003c\/th\u003e\n\u003ctd\u003e2048 PPR. Z specifies index. Code 1 specifies single output.\u003c\/td\u003e\n\u003ctd\u003eV07 1⅛ in bore. C denotes the latching connector with ½ in NPT.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRIM Tach 8500 \/ 8500 Quad (legacy)\u003c\/th\u003e\n\u003ctd\u003eRead original label and legacy order table.\u003c\/td\u003e\n\u003ctd\u003eLegacy manual specifies a 5–15 V supply at the connector. Pin 5 is unassigned in its wiring table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.dynapar.com\/ecatalog\/encoder-products\/product-details\/RT81024LF082Q?hsLang=en\"\u003e1024 PPR exact record\u003c\/a\u003e · \u003ca href=\"https:\/\/www.dynapar.com\/ecatalog\/encoder-products\/product-details\/RT82048ZV071C\"\u003e2048 PPR exact record\u003c\/a\u003e · \u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/NexGen_RT8500_IM_702869_1_D.pdf#page=8\"\u003eRT8 order and outline (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/RIM8500_IM_791-1060-00_B.pdf?hsLang=en\"\u003eLegacy wiring (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eDynapar marks the original RIM Tach 8500 discontinued and identifies the NexGen RT8 as its successor. Dynapar lists RT8 product configurations and a legacy wheel\/sensor upgrade kit. Match the original face, wheel, PPR, termination and voltage before selecting an upgrade. Reviewed 7 November 2026. \u003ca href=\"https:\/\/www.dynapar.com\/en\/products-and-solutions\/incremental-encoders\/rim_8500\"\u003eDynapar legacy 8500 lifecycle notice\u003c\/a\u003e · \u003ca href=\"https:\/\/www.dynapar.com\/en\/products-and-solutions\/incremental-encoders\/rt8rim8500\"\u003eNexGen RT8 product page\u003c\/a\u003e · \u003ca href=\"https:\/\/www.dynapar.com\/products_and_solutions\/nrtk-upgrade-kit\"\u003eDynapar NRTK upgrade kits\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"NexGen RT8, manual 702869-0001 and exact examples\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eNexGen RT8, manual 702869-0001 and exact examples\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue \/ condition\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring method\u003c\/th\u003e\n\u003ctd\u003eBearingless magnetic incremental with differential line-driver outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003e5–26 V DC in the exact RT8 product records and ratings. Typical 95 mA per module plus line-driver load. The manual pin table prints 5–24 V at Vcc. Confirm the exact nameplate and installation revision before using a supply above 24 V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency and shaft speed\u003c\/th\u003e\n\u003ctd\u003e180 kHz data\/index frequency limit and 7,000 rpm mechanical maximum. The installed PPR and receiving input can set a lower usable speed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMount and shaft runout\u003c\/th\u003e\n\u003ctd\u003eNEMA 8.5 in 180C face. Maximum shaft runout 0.005 in TIR in the NexGen manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDocumented radial gap\u003c\/th\u003e\n\u003ctd\u003eFor ≤1200 PPR, 0.075 in +0.015\/−0.070 in. For \u0026gt;1200 PPR, 0.050 in +0.015\/−0.040 in. Use the matching assembly procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e−40 to +100 °C operating. The sealed latching connector is listed IP65.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eCalculate pulse frequency as PPR × shaft rpm ÷ 60. A 2048 PPR wheel at 6000 rpm would produce 204.8 kHz, above the documented 180 kHz limit. Use both limits and the drive input specification when commissioning. \u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/NexGen_RT8500_IM_702869_1_D.pdf#page=1\"\u003eNexGen ratings (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe pulse wheel rotates on the motor shaft. The sensor module fits in the stationary C-face housing. Check the actual wheel style first. A through-shaft clamp and an end-of-shaft adapter have separate installation instructions. Seat the housing squarely on the face, then position the wheel axially under the sensor before securing it.\u003c\/p\u003e\n\u003cp\u003eIn the illustrated through-shaft procedure, the front face of the wheel aligns with the indicated cover surface. The four wheel-clamp screws are tightened in a star pattern to a nominal \u003cstrong\u003e35 in·lbf\u003c\/strong\u003e for that assembly. End-of-shaft adapters use a different procedure in the manual. Verify the actual kit and mounting drawing before using a torque. Check for axial migration, shaft runout, rubbing and a fully seated sensor if pulses disappear once per revolution. \u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/NexGen_RT8500_IM_702869_1_D.pdf#page=4\"\u003eThrough-shaft procedure (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/NexGen_RT8500_IM_702869_1_D.pdf#page=6\"\u003eEnd-of-shaft procedure (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe drive or counter measures pulses as the magnetic wheel passes the sensor. The lead\/lag relationship of A and B gives direction. On the documented RT8, A leads B for counterclockwise motion as viewed from the male C-face end. Differential receivers use each channel with its complement. Z provides a repeatable index on builds that have that option. It does not supply absolute position after power loss.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"NexGen RT8 connector assignments, manual page 1\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eNexGen RT8 connector assignments, manual page 1\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSignal\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eLatching pin\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMS pin\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFactory pigtail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e0 V common\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eB \/ B complement\u003c\/th\u003e\n\u003ctd\u003e2 \/ 7\u003c\/td\u003e\n\u003ctd\u003eE \/ H\u003c\/td\u003e\n\u003ctd\u003eGreen \/ yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA \/ A complement\u003c\/th\u003e\n\u003ctd\u003e3 \/ 8\u003c\/td\u003e\n\u003ctd\u003eD \/ G\u003c\/td\u003e\n\u003ctd\u003eBlue \/ gray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZ \/ Z complement, if fitted\u003c\/th\u003e\n\u003ctd\u003e4 \/ 9\u003c\/td\u003e\n\u003ctd\u003eC \/ I\u003c\/td\u003e\n\u003ctd\u003eViolet \/ orange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlarm, if fitted\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003eUnavailable on the plain pigtail option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVcc\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShield\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eBraid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eIdentify terminals by the housing marks and manual view. Compare the receiver’s input type and voltage limits. Keep unused outputs insulated individually and follow the grounding arrangement for the actual installation. The legacy pin-5 assignment is separate. \u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/NexGen_RT8500_IM_702869_1_D.pdf#page=1\"\u003eNexGen connector table (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/RIM8500_IM_791-1060-00_B.pdf?hsLang=en\"\u003eLegacy connector table (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe RT8 attaches to the motor face and uses an external sensor-to-drive cable. The order termination code selects the matching latching or MS connector, plain pigtail, or connector-on-lead configuration. Q is the 18 in latching lead configuration in the documented example. The C and F orders differ in mating-connector provision. Read the actual code before ordering a mating hood or cable.\u003c\/p\u003e\n\u003cp\u003eUse a shielded cable with the documented pair grouping. Keep the cable away from motor leads. Confirm the exact mating accessory number, cable length and termination for the installed receiver and environment. \u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/NexGen_RT8500_IM_702869_1_D.pdf#page=8\"\u003eRT8 connector ordering (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.dynapar.com\/products_and_solutions\/nrtk-upgrade-kit\"\u003eReplacement wheel and sensor families\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolate the machine and secure the shaft.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect.\u003c\/strong\u003e Check hood retention, damaged or pushed-back contacts, conductive dust, oil, cable support and the sensor seating. Check that the wheel clamp has not moved on the shaft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated cable tests.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply and outputs.\u003c\/strong\u003e With an approved breakout fitted while off, a qualified technician can measure DC between 6 and 1 on the latching map. Compare the module and receiver ends under load. Read the RT8 LED against the manual and compare pulses with a suitable differential scope or counter. A steady green at rest differs from flashing green with wheel motion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocate the fault.\u003c\/strong\u003e No pulse at the module despite correct power and motion calls for wheel, gap and sensor checks. A clean module signal and a poor drive signal point to the cable, input setting or interference. A loss at high speed calls for checking calculated pulse frequency. A repeatable once-per-turn dropout points toward wheel position or runout.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eDynapar specifies the 180C motor face for AC and DC motor velocity and position feedback. The F44, F47, F60 and F68 end-of-shaft wheel codes are tied to the motor series listed in the RT8 manual. Confirm the exact motor and shaft before selecting a wheel. \u003ca href=\"https:\/\/www.dynapar.com\/en\/products-and-solutions\/incremental-encoders\/rt8rim8500\"\u003eDynapar motor applications\u003c\/a\u003e · \u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/NexGen_RT8500_IM_702869_1_D.pdf#page=8\"\u003eWheel order codes (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eThe normal setup for this external speed encoder is mechanical wheel alignment and receiver direction, PPR and index verification. If the machine uses the index as a datum, record its required relation to the mechanism before moving the wheel. Complete the machine’s homing and speed feedback checks after replacement. Any separate servo commutation alignment follows its own motor and drive procedure.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/NexGen_RT8500_IM_702869_1_D.pdf\"\u003eNexGen RT8 installation instructions 702869-0001 (PDF)\u003c\/a\u003e. Page 1 wiring and limits, pages 4–7 assembly, page 8 ordering and dimensions.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/RIM8500_IM_791-1060-00_B.pdf?hsLang=en\"\u003eLegacy 8500 and 8500 Quad manual (PDF)\u003c\/a\u003e. Use for the older supply, pin assignments and wheel instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.dynapar.com\/en\/products-and-solutions\/incremental-encoders\/rt8rim8500\"\u003eDynapar RT8 product and resource page\u003c\/a\u003e. Catalogue links to the series data sheet and additional wheel instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading (Est. 2003]","offers":[{"title":"Default Title","offer_id":51117001965733,"sku":"sfi89","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/DynaparNorthStarNexGenRIMTach8500RT8EncoderTechnicalGuideServiceVisitforInstallation_Repair_Alignment.jpg?v=1794122183","url":"https:\/\/www.sparefaber.com\/de\/products\/dynapar-rim-tach-8500-rt8","provider":"SpareFaber","version":"1.0","type":"link"}