{"product_id":"festo-emms-as-190-m-hs-arb-feedback-service-guide","title":"Festo EMMS-AS-190-M-HS-ARB Resolver Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eFesto EMMS-AS-190-M-HS-ARB\u003c\/strong\u003e — Resolver. This guide helps identify the fitted feedback, distinguish a cable or setup fault and prepare a scoped repair, installation or alignment assessment. SpareFaber accepts UAE site-service and send-in evaluation enquiries after reviewing the motor\/feedback labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentification\u003c\/a\u003e · \u003ca href=\"#testing\"\u003eTesting scope\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eService enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted configuration\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eItem\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer \/ application\u003c\/td\u003e\n\u003ctd\u003eFesto EMMS-AS-190-M-HS-ARB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback\u003c\/td\u003e\n\u003ctd\u003eResolver — 2-pole resolver; exact fitted device ID unverified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM catalogue part number\u003c\/td\u003e\n\u003ctd\u003e1584939\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor mounting\u003c\/td\u003e\n\u003ctd\u003e190 nominal flange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraked representative\u003c\/td\u003e\n\u003ctd\u003eEMMS-AS-190-M-HS-ARB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHolding brake\u003c\/td\u003e\n\u003ctd\u003eB; 30 Nm; 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpareFaber service reference\u003c\/td\u003e\n\u003ctd\u003eTCG1407\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe service reference is not an OEM part number. Verify the complete fitted labels and connector revision before selecting a replacement or test connection.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"testing\"\u003e\u003ch2\u003eSpecialist feedback testing\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX:\u003c\/strong\u003e EMMS-AS resolver checks via documented M23 path, after confirming excitation and motor-side pin map. No serial-memory functions apply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting connection:\u003c\/strong\u003e TI-5901 M23 feedback. Power: TI-3027 M23 for size 140; TI-3048 M40 for size 190, subject to pin\/key verification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModule \/ software:\u003c\/strong\u003e Use the matching resolver setup; exact Athena\/firmware minimum and motor-specific alignment profile were not established.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor-run scope:\u003c\/strong\u003e TI-3000JX conditional only. Match actual motor\/brake rating, power connector and supported run profile; available power cable alone is not run approval.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSignals and specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented value \/ limit\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete motor order\u003c\/td\u003e\n\u003ctd\u003eEMMS-AS-190-M-HS-ARB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM part number\u003c\/td\u003e\n\u003ctd\u003e1584939\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback\u003c\/td\u003e\n\u003ctd\u003e2-pole resolver; sine\/cosine analogue signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal mounting size\u003c\/td\u003e\n\u003ctd\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor feedback connector\u003c\/td\u003e\n\u003ctd\u003eM23, resolver motor-side pin map\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power connector\u003c\/td\u003e\n\u003ctd\u003eM40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHolding brake\u003c\/td\u003e\n\u003ctd\u003eB; 30 Nm; 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback device supplier \/ internal ID\u003c\/td\u003e\n\u003ctd\u003eNot established for the fitted unit; verify the physical label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eSignal periods, serial position bits, turn range and drive-scaled counts describe different quantities. Use the exact encoder option and controller configuration when comparing readings.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mechanical-fit\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003eThe EMMS-AS-190-M-HS-ARB is the braked, high-voltage standard-winding resolver order identified by Festo part 1584939. The B suffix belongs to the holding-brake selection. Confirm the complete order before using the 140\/190 drawings: resolver and serial-encoder rear assemblies are not identified by the flange number alone.\u003c\/p\u003e\n\u003cp\u003eUse PDF pages 21–22 for shaft, pilot, fixing holes and resolver\/brake dimensions. The 140 model is a nominal flange class; the drawing gives B1 as 140.5 mm. The S\/L or S\/M length changes the motor package and must match the available machine space. Internal resolver retention, coupling details and service torque remain specific to the fitted unit.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eFesto’s PDF page 14 is explicitly the motor-side pin allocation. Confirm the connector face and pin view in the drawing before using this summary.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eM23 resolver contact\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSignal\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 \/ 2\u003c\/td\u003e\n\u003ctd\u003eR1 exciter + \/ R2 exciter −\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 \/ 4\u003c\/td\u003e\n\u003ctd\u003eS1 cosine + \/ S3 cosine −\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 \/ 6\u003c\/td\u003e\n\u003ctd\u003eS2 sine + \/ S4 sine −\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7–12\u003c\/td\u003e\n\u003ctd\u003eNot connected in the documented assignment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe resolver needs the correct AC excitation and supported tester settings; this table is not an instruction to connect a DC supply to its windings. Use the exact OEM\/tester procedure. Motor power, temperature and brake contacts are separately mapped on page 14; size 190 uses M40 power while size 140 uses M23 power.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"cables\"\u003e\u003ch2\u003eInternal, machine and test cables\u003c\/h2\u003e\n\u003cp\u003eTI-5901 M23 feedback. Power: TI-3027 M23 for size 140; TI-3048 M40 for size 190, subject to pin\/key verification.\u003c\/p\u003e\n\u003cp\u003eMatch connector keying and the motor-side assignment before choosing the Mitchell lead. This test lead is not an OEM machine harness. The exact machine cable order, internal resolver loom and any replacement harness are not established by the motor part number alone; use cable labels and both-end wiring documentation.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cp\u003eFollow the site isolation procedure before physical checks: secure the driven load, lock out relevant energy sources, observe the drive discharge time and have a qualified technician verify isolation. Disconnect both cable ends before continuity or short testing and account for intentional shield bonds. Powered measurements, rotation, brake release and alignment require the applicable specialist procedure.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObserved symptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eUseful next check\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolver alarm or missing angle\u003c\/td\u003e\n\u003ctd\u003eCheck connector condition, correct excitation path and isolated cable continuity. Compare sine\/cosine circuits through the exact OEM drawing before judging the resolver.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAngle changes intermittently with movement\u003c\/td\u003e\n\u003ctd\u003eInspect cable strain and connector retention; separate machine cable, motor bulkhead and internal resolver paths.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor resists motion or overheats during an attempted run\u003c\/td\u003e\n\u003ctd\u003eStop and verify holding-brake release and the correct motor\/brake supplies under the approved procedure. A feedback pass does not prove the power or brake circuit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncorrect direction or phase-related fault after service\u003c\/td\u003e\n\u003ctd\u003ePreserve the symptom and incoming references; check phase and resolver polarity conventions before any alignment change.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, offsets and memory\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming resolver position and mechanical coupling reference before removal. Confirm motor phases, polarity, direction and the drive’s referencing convention before alignment. The guide does not assign a universal electrical angle to this motor, and the listed feedback lead does not establish an automatic TI-3000JX run\/alignment profile.\u003c\/p\u003e\n\u003cp\u003eThis selected configuration is a resolver; the EnDat memory functions and serial-only Line Levels exception discussed elsewhere for EMMS-AS do not apply to it. Do not replace it with a serial-encoder version merely because the flange matches.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eThe exact Festo part-number datasheet is marked for discontinuation. The source does not establish a present-day stock position, final order date or verified interchangeable successor. Keep that status separate from the ability to evaluate an existing motor’s resolver.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor applications and related guides\u003c\/h2\u003e\n\u003cp\u003eThis page covers the exact braked resolver order shown above. EMMS-AS-140-MX1-RS and other EMMS-AS serial-encoder orders use a different feedback path. Compare complete motor order, drive input, brake and power connector before proposing a replacement.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.sparefaber.com\/products\/festo-emms-as-140-mx1-rs-565300-eci1118-endat-feedback\" target=\"_blank\" rel=\"noopener\"\u003eFesto EMMS-AS-140-MX1-RS ECI 1118 EnDat Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.sparefaber.com\/products\/festo-emms-as-70-m-ls-rs-550118-endat-feedback\" target=\"_blank\" rel=\"noopener\"\u003eFesto EMMS-AS-70-M-LS-RS 550118 EnDat22 Motor Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings and primary documents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/ftp.festo.com\/public\/pneumatic\/SOFTWARE_SERVICE\/Documentation\/2018\/EN\/EMMS-AS_EN.PDF\" target=\"_blank\" rel=\"noopener\"\u003eFesto EMMS-AS catalogue, 2017\/11\u003c\/a\u003e — PDF pp. 3, 9–11, 14, 21–22, 28–29.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/23778408694939-FESTO-EMME-AS-EMMS-AS-and-EMMT-AS-Series\" target=\"_blank\" rel=\"noopener\"\u003eMitchell: Festo EMME-AS, EMMS-AS and EMMT-AS\u003c\/a\u003e — EMMS-AS; resolver technical data; resolver connector paragraph.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/ftp.festo.com\/public\/PNEUMATIC\/SOFTWARE_SERVICE\/DataSheet\/EN_GB\/1584939.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFesto EMMS-AS-190-M-HS-ARB, part 1584939\u003c\/a\u003e — PDF pp.1–2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication evidence:\u003c\/strong\u003e F1 pp.11,14,21–22,29; F1584939 pp.1–2. F2: EMMS-AS → Resolver Technical Data and resolver M23 connector paragraph.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"faq\"\u003e\u003ch2\u003eFAQ and service enquiry\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIs this an EnDat motor?\u003c\/summary\u003e\u003cp\u003eNo. This specific EMMS-AS-190-M-HS-ARB \/ 1584939 selection uses a resolver. Other EMMS-AS orders have serial encoders; the suffix and exact part number matter.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed lead prove the motor is ready to run?\u003c\/summary\u003e\u003cp\u003eNo. TI-5901 supports the documented resolver connection. A powered motor run also needs the correct power lead, brake supply, tester limits, released profile and mechanical setup.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat should I send with a service enquiry?\u003c\/summary\u003e\u003cp\u003eProvide the complete motor and feedback labels, drive model, connector photos, alarm text, fault timing and previous repair\/replacement history. Include cable labels and any OEM installation drawing. This lets SpareFaber distinguish a site investigation from a send-in feedback or motor assessment.\u003c\/p\u003e\u003c\/details\u003e\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or send-in evaluation\u003c\/a\u003e. Scope, parts and turnaround are confirmed after the fitted configuration and fault are reviewed.\u003c\/p\u003e\u003c\/section\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":51274027499685,"sku":"TCG1407","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/festo-emms-as-190-m-hs-arb-feedback-service-guide.png?v=1795333106","url":"https:\/\/www.sparefaber.com\/de\/products\/festo-emms-as-190-m-hs-arb-feedback-service-guide","provider":"SpareFaber","version":"1.0","type":"link"}