{"product_id":"festo-emms-as-55-m-ls-tm-eqi-1130-endat-feedback","title":"Festo EMMS-AS-55-M-LS-TM HEIDENHAIN EQI 1130 EnDat Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eRead the complete Festo order and item number before choosing the test. Item 550111 is the multiturn EnDat motor. The singleturn and resolver builds look similar in the catalogue.\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE on-site fault diagnosis, installation and alignment checks for the documented feedback. Send the fitted labels and alarm details to arrange a visit or a send-in evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Festo EMMS-AS-55-M-LS-TM HEIDENHAIN EQI 1130 EnDat Feedback technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Verify the EnDat 2.2 selection, supply and fitted connector before a TI-5000JX serial check. Mitchell’s article documents direct and motor-side branches with different requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Confirm the exact motor order, amplifier, fixture and commissioning data before a run test.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e Family leads TI-5668 for the stated EnDat 2.1 direct branch and TI-5662 for the stated 8-contact M12 branch. Exact 550111 fixture open.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eFesto EMMS-AS-55-M-LS-TM HEIDENHAIN EQI 1130 EnDat Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMMS-AS-55-M-LS-TM · 550111\u003c\/th\u003e\n\u003ctd\u003eFesto’s exact size-55 multiturn motor order. Mitchell links this motor as an EQI 1130 example.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHEIDENHAIN EQI 1130\u003c\/th\u003e\n\u003ctd\u003eEncoder family named for that example. The complete HEIDENHAIN ID and connector revision come from the fitted encoder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e550110 · EMMS-AS-55-M-LS-TS\u003c\/th\u003e\n\u003ctd\u003eSeparate singleturn motor order in the Festo catalogue.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1569788 · EMMS-AS-55-M-LS-RR\u003c\/th\u003e\n\u003ctd\u003eResolver order for this size and motor family. Use its own connection drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor encoder interface\u003c\/th\u003e\n\u003ctd\u003eEnDat 2.2 for Festo item 550111 in its exact product datasheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd\u003eInductive absolute multiturn. The 550111 datasheet lists 19-bit encoder resolution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor size\u003c\/th\u003e\n\u003ctd\u003eNominal 55 flange size in the Festo series catalogue. Use the size-55 outline for mounting and shaft dimensions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe drive requests position over the EnDat clock and data lines. Mitchell says the documented EMMS-AS serial arrangements do not use the incremental outputs. A line-level test intended for analogue incremental channels does not diagnose the serial path.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the Festo size-55 motor outline for the flange, pilot and output shaft. The EQI 1130 sits inside the motor and needs the exact encoder drawing for its own seating, coupling and fasteners. Capture its installed clocking and cable routing before disturbance.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eSeparate the motor plug and the connector on the EQI 1130. Use the actual Festo connector table and fitted HEIDENHAIN drawing for supply, return, clock and data. Mitchell’s TI-5668 note names an EnDat 2.1 direct branch, while the exact Festo datasheet lists EnDat 2.2. Confirm the lead and software against this encoder before connecting.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eSelect Festo’s external encoder lead from the catalogue by drive and actual motor plug. Mitchell’s generic EnDat direct lead and its M12 motor lead are separate fixtures. Source the internal EQI harness from the fitted connector and motor assembly documentation.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eUse only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo analogue signal on the tester\u003c\/th\u003e\n\u003ctd\u003eCheck the serial EnDat path and response first. This application uses serial feedback.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo serial response\u003c\/th\u003e\n\u003ctd\u003eVerify the fitted EnDat generation, tester profile and direct-versus-bulkhead lead. Trace the isolated clock and data pairs and check connector seating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition reads but the drive trips after replacement\u003c\/th\u003e\n\u003ctd\u003eVerify the fitted ID, commissioning data, coupling and reference. Read the drive alarm before altering memory.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRead and preserve the original commissioning record and any accessible encoder memory. Record the mechanical and electrical reference before removal. Recommission using the Festo motor and drive procedure and verify position and multiturn behavior before handing back the axis.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eFesto EMMS-AS, size 55, exact motor order EMMS-AS-55-M-LS-TM\u003c\/p\u003e\n\u003cp\u003eConfirm the fitted HEIDENHAIN ID, EnDat 2.2 fixture and internal loom identifier.\u003c\/p\u003e\n\u003ch3\u003eRelated SpareFaber guides\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/de\/products\/festo-emms-as-70-m-ls-rs-550118-endat-feedback\"\u003eFesto EMMS-AS-70-M-LS-RS 550118 EnDat22 Motor Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/de\/products\/festo-emmt-as-100-s-hs-rmb-eqi1331-feedback\"\u003eFesto EMMT-AS-100-S-HS-RMB EQI 1331 EnDat 2.2 Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/23778408694939-FESTO-EMME-AS-EMMS-AS-and-EMMT-AS-Series\"\u003eFesto EMME-AS, EMMS-AS and EMMT-AS Series\u003c\/a\u003e. EMMS-AS, linked EQI 1130 motor example\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/ftp.festo.com\/Public\/PNEUMATIC\/SOFTWARE_SERVICE\/Datasheet\/EN_US\/550111.pdf\"\u003eFesto item 550111 technical datasheet\u003c\/a\u003e. Exact motor and its EnDat 2.2 and encoder resolution data.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/ftp.festo.com\/Public\/PNEUMATIC\/SOFTWARE_SERVICE\/Documentation\/2019\/EN\/EMMS-AS_EN.PDF\"\u003eFesto EMMS-AS catalogue and dimension drawings\u003c\/a\u003e. Motor type key, flange and shaft outlines, connector assignments and cable accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/ftp.festo.com\/public\/PNEUMATIC\/SOFTWARE_SERVICE\/DataSheet\/550111.html\"\u003eFesto manufacturer item 550111\u003c\/a\u003e. Exact motor order and manufacturer data downloads.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51127940841637,"sku":"TCG212","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/festo-emms-as-55-m-ls-tm-eqi-1130-endat-feedback-service-guide.jpg?v=1794245947","url":"https:\/\/www.sparefaber.com\/de\/products\/festo-emms-as-55-m-ls-tm-eqi-1130-endat-feedback","provider":"SpareFaber","version":"1.0","type":"link"}