{"product_id":"hengstler-ad34-ssi-compact-absolute-encoder","title":"Hengstler AD34 SSI Compact SSI Absolute Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eRead the AD34 interface and supply fields together. Hengstler documents SSI Gray and binary options with different terminations and analogue outputs. The full order tells you what to expect at the connector.\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE on-site fault diagnosis, installation and alignment checks for the documented feedback. Send the fitted labels and alarm details to arrange a visit or a send-in evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Hengstler AD34 SSI Compact SSI Absolute Encoder technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Use SSI after verifying the complete order code, resolution and connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Specific motor-run setup remains open.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e Verify the complete AD34 SSI order and direct breakout.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eHengstler AD34 SSI Compact SSI Absolute Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAD34 SC \/ SD\u003c\/th\u003e\n\u003ctd\u003eThe manufacturer order table names SC for SSI Gray plus 1 Vpp and SD for SSI binary plus 1 Vpp.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAD34 SG \/ SB\u003c\/th\u003e\n\u003ctd\u003eSSI Gray or binary order choices in the stated cable termination grouping. Verify the exact order and drawings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAD34 BC \/ BV\u003c\/th\u003e\n\u003ctd\u003eBiSS options in the same family, with their own receiving profile. Read the actual interface characters.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution choices\u003c\/th\u003e\n\u003ctd\u003eThe cited family table lists 12–22 singleturn bits, with 12 turn bits on listed multiturn orders. Verify the resolution field.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply codes\u003c\/th\u003e\n\u003ctd\u003eA is 5 V DC and E is 7–30 V DC in the cited order table. Match the exact label before connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShaft and stator support\u003c\/th\u003e\n\u003ctd\u003eThe stated F.0N or U.0N order choices use a 6 mm notched shaft and different spring-tether directions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003eAxial or radial 12-contact PCB arrangement and optional mating connector\/cable, as shown in the order table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eSSI uses a clock from the receiver and a serial data word from the encoder. On SC and SD, the separate 1 Vpp channels can be assessed independently. Match the decoding format and bit count to the actual order.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the AD34 drawing for F or U spring-tether direction, notch geometry and axial or radial connector. Check available clearance and the original shaft reference before swapping a similar housing.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eUse the manufacturer’s two-row connector view and matching interface code. Confirm supply and return, clock and data polarity, and the optional analogue pairs. The drawing shows separate supply-sense connections.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Connection reference for the stated view\" tabindex=\"0\"\u003e\u003ctable id=\"wiring-table\"\u003e\n\u003ccaption\u003eConnection reference for the stated view\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eContact or circuit\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1b and 4b\u003c\/th\u003e\n\u003ctd\u003eSupply and 0 V on the documented AD34 connector table. Use the actual A or E code for voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2b\/5a and 1a\/6b\u003c\/th\u003e\n\u003ctd\u003eClock pair and data pair in the cited connector view. Verify polarity from the original drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue pairs\u003c\/th\u003e\n\u003ctd\u003eCompare the selected interface characters with the drawing before expecting sine and cosine.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eUse the exact cable termination and PCB connector code when identifying the harness. Retain the specified pair and shield arrangement. Use the fitted motor drawing to identify any motor-bulkhead map.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eUse only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition jumps at regular points\u003c\/th\u003e\n\u003ctd\u003eCheck word length and SSI Gray or binary decoding before changing the encoder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDigital angle good, no sine or cosine\u003c\/th\u003e\n\u003ctd\u003eVerify whether the full code specifies the analogue channels, then check the fitted pairs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCount intermittent after replacement\u003c\/th\u003e\n\u003ctd\u003eCheck the tether orientation, shaft fit and the correct axial or radial connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003ePreserve the mechanical and machine position reference. Verify Gray or binary configuration, turn mode, direction and any motor-specific commissioning settings.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eAD34 SSI installation, confirm exact motor and order\u003c\/p\u003e\n\u003cp\u003eIdentify the SSI order and fitted shaft before comparing a BiSS AD34 or a larger AD58.\u003c\/p\u003e\n\u003ch3\u003eRelated SpareFaber guides\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/de\/products\/hengstler-ad36-biss-c\"\u003eHengstler ACURO AD36 BiSS-C Encoder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/de\/products\/hengstler-ad58-0547029-biss-b\"\u003eHengstler AD58\/0022E1.0KBI0 0547029 BiSS-B Encoder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/de\/products\/kollmorgen-akm-ab-biss-b-multiturn-feedback\"\u003eKollmorgen AKM AB BiSS-B Multiturn Servo Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/de\/products\/hengstler-ax65-0569024-ssi-encoder\"\u003eHengstler AX65\/1612EL.72SG1 0569024 SSI Multiturn Encoder\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/45936997944347-Hengstler-Encoders\"\u003eHengstler Encoders\u003c\/a\u003e. Absolute Encoders, AD34 listed with BiSS and SSI options\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26657551576603-Unico-SSI-Serial-Encoders\"\u003eUnico SSI Serial Encoders\u003c\/a\u003e. Supplementary reference for the stated model or setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.dynapar.com\/hubfs\/downloads\/AD34_DS_702916-0001.pdf?hsLang=en\"\u003eHengstler AD34 technical data\u003c\/a\u003e. Manufacturer order key, 6 mm shaft and tether options, PCB pin table and SSI\/BiSS interface choices.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51131230912677,"sku":"TCG285","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/hengstler-ad34-ssi-compact-absolute-encoder-service-guide.jpg?v=1794277664","url":"https:\/\/www.sparefaber.com\/de\/products\/hengstler-ad34-ssi-compact-absolute-encoder","provider":"SpareFaber","version":"1.0","type":"link"}