{"product_id":"keba-lti-lst-190-2-hiperface-dsl-singleturn-multiturn-feedback-technical-guide","title":"KEBA \/ LTi LST-190-2 HIPERFACE DSL EKS36 \/ EKM36 Singleturn \/ Multiturn Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eKEBA \/ LTi LST-190-2\u003c\/strong\u003e with HIPERFACE DSL EKS36 \/ EKM36 is covered in this technical guide. Use it to identify the fitted assembly, compare the documented feedback branches, preserve incoming alignment and readable data, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentification\u003c\/a\u003e · \u003ca href=\"#testing\"\u003eTesting\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mechanical-fit\"\u003eMechanical fit\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDocuments\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eService enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted motor and feedback\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eIdentification item\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eScoped information\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer \/ grouped base\u003c\/td\u003e\n\u003ctd\u003eKEBA \/ LTi LST-190-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTCG1652; SpareFaber service-guide reference, not an OEM part number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame \/ family\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue M0 \/ stall reference\u003c\/td\u003e\n\u003ctd\u003e32 Nm; match the selected catalogue row, conditions and complete fitted order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling \/ assembly\u003c\/td\u003e\n\u003ctd\u003eCatalogue LST build; identify any fitted external fan, brake and thermal options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor-data source\u003c\/td\u003e\n\u003ctd\u003eKEBA LSN\/LST catalogue, motor table p.100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical source\u003c\/td\u003e\n\u003ctd\u003ep.101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoverage boundary\u003c\/td\u003e\n\u003ctd\u003esingleturn and multiturn options; base identifier omits complete speed\/winding\/shaft\/brake\/factory suffixes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003ePhotograph the complete motor plate, serial, encoder label, feedback connector face and drive nameplate before disturbing the assembly. Record the actual brake, shaft, mounting, cooling, thermal sensor and speed\/winding fields. G7.2S \/ G7.2M — EKS36 \/ EKM36, 18-bit is the documented branch grouping used here; it is not a full factory order or an authorization to exchange devices.\u003c\/p\u003e\n\u003cp\u003eG7.2S\/M is the documented 18-bit EKS36\/EKM36 grouping. G7.2SY\/MY safety-labelled variants need separate label and installation review; this guide does not validate a machine safety function. G6.x classic HIPERFACE and G3\/G5\/G12.x optical feedback remain different branches.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"testing\"\u003e\u003ch2\u003eSpecialist feedback testing\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDevice-level test scope:\u003c\/strong\u003e Use TI-5106 with TI-5000JX, the supported installed software edition and a cable verified for the actual G7.2S\/EKS36 or G7.2M\/EKM36 hybrid assembly. Check the encoder label and readback before applying an electronic alignment or memory function. A generic DSL capability does not establish a tested LST motor-specific profile or lead.\u003c\/p\u003e\n\u003cp\u003eRecord the tester hardware, lead\/module, software version, selected feedback type and actual fitted label with the report. First record the incoming fitted-device configuration and relevant position\/signal observations. Preserve supported readable identity and data before any write. A changing count or angle alone does not prove correct mechanical installation, signal quality, commutation sequence or drive configuration.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eTest record\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat the observation establishes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabel and setup match\u003c\/td\u003e\n\u003ctd\u003eThe selected device, electrical interface and supply\/excitation match the identified branch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlow manual movement\u003c\/td\u003e\n\u003ctd\u003eDirection, continuity, cyclic behaviour and the applicable index\/turn transition can be compared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus \/ alarm readback\u003c\/td\u003e\n\u003ctd\u003eDevice-reported status can be separated from cable\/controller symptoms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue levels where present\u003c\/td\u003e\n\u003ctd\u003eCompare exposed A\/B quality independently of serial position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBefore\/after report\u003c\/td\u003e\n\u003ctd\u003eIncoming configuration and each approved service change remain traceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eMotor-run scope:\u003c\/strong\u003e TI-5000JX feedback evaluation and TI-3000JX motor-run approval are separate decisions. Establish full motor parameters, pole count, phase convention, fixture\/load, brake handling and speed\/current limits before a run. A supported feedback protocol does not approve a run profile for this complete motor. No universal minimum firmware or exact motor-bulkhead adapter is asserted here.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eMotor data and singleturn\/multiturn comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eG7.2S singleturn\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eG7.2M multiturn\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoder family\u003c\/td\u003e\n\u003ctd\u003eEKS36\u003c\/td\u003e\n\u003ctd\u003eEKM36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink\u003c\/td\u003e\n\u003ctd\u003eTwo-wire HIPERFACE DSL\u003c\/td\u003e\n\u003ctd\u003eTwo-wire HIPERFACE DSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute positions \/ revolution\u003c\/td\u003e\n\u003ctd\u003e262,144 (18 bits)\u003c\/td\u003e\n\u003ctd\u003e262,144 (18 bits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute revolutions\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e4,096 (12 additional turn bits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue A\/B\u003c\/td\u003e\n\u003ctd\u003eNot exposed by the two-wire DSL link\u003c\/td\u003e\n\u003ctd\u003eNot exposed by the two-wire DSL link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply and exact variant\u003c\/td\u003e\n\u003ctd\u003eCheck fitted encoder label and hybrid drawing\u003c\/td\u003e\n\u003ctd\u003eCheck fitted encoder label and hybrid drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety suffix boundary\u003c\/td\u003e\n\u003ctd\u003eG7.2SY requires its own identification\u003c\/td\u003e\n\u003ctd\u003eG7.2MY requires its own identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe catalogue torque reference for this grouped base is 32 Nm. It is used for identification and priority, not as momentary peak torque or a guaranteed rating for every speed\/winding\/cooling condition. Keep stall M0, rated Mn and short-duration Mmax separate. Match the complete winding, thermal class, mounting and cooling conditions of the selected catalogue row.\u003c\/p\u003e\n\u003cp\u003eST and MT stay in this single DSL guide. MT contributes the documented revolution field; it does not turn a different singleturn device into a multiturn assembly by changing a controller setting.\u003c\/p\u003e\n\u003cp\u003eG7.2S\/M is the documented 18-bit EKS36\/EKM36 grouping. G7.2SY\/MY safety-labelled variants need separate label and installation review; this guide does not validate a machine safety function. G6.x classic HIPERFACE and G3\/G5\/G12.x optical feedback remain different branches.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mechanical-fit\"\u003e\u003ch2\u003eMechanical fit, cooling and removal reference\u003c\/h2\u003e\n\u003cp\u003eUse p.101 for the 190-frame drawing. The 190\/220-frame table groups G6.2x and G7.2x in a length column; retain the actual brake, shaft, housing and connector subcase. Record the complete order and fitted holder before selecting a replacement.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFit item\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRecord and compare\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlange \/ pilot \/ mounting holes\u003c\/td\u003e\n\u003ctd\u003eUse the exact drawing and mounting version, including connector clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft \/ key \/ coupler\u003c\/td\u003e\n\u003ctd\u003eRecord actual dimensions, insertion depth and machine reference before removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoder mounting\u003c\/td\u003e\n\u003ctd\u003eIdentify holder, coupling, fasteners and mechanical reference from the fitted device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake and fan\u003c\/td\u003e\n\u003ctd\u003eIdentify options and added envelope; verify their separate electrical circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeals \/ coolant \/ enclosure\u003c\/td\u003e\n\u003ctd\u003eMatch the actual cooling arrangement and ingress-protection build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eMark the incoming relationship between motor housing, feedback body, shaft and machine reference. Support the assembly without loading the encoder shaft or bearing through an improvised puller. Use the documented removal and assembly method for the fitted device; no unreviewed taper, fastening torque, air gap or insertion force is supplied by this grouped guide.\u003c\/p\u003e\n\u003cp\u003eMechanical drawings to compare: p.101. Connector orientation and holder variants can change practical clearance even where the nominal frame is the same. A similar-looking donor motor does not establish identical shaft, brake or encoder fit.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eKEBA p.116 supplies the hybrid-connector reference for this G7.2x branch. Identify the fitted I17\/I40 arrangement, contact-side view and full motor\/encoder order. The optical M23 assignment on p.115 and the G6.x classic-HIPERFACE supply route do not establish this DSL pinout.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eCircuit \/ branch\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eIdentification boundary\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSL pair\u003c\/td\u003e\n\u003ctd\u003eUse the G7.2x two-wire feedback route and actual connector contact view\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHybrid I17 \/ I40\u003c\/td\u003e\n\u003ctd\u003eMatch the fitted housing and the corresponding p.116 drawing; keep phase and feedback circuits distinct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply and return\u003c\/td\u003e\n\u003ctd\u003eUse the fitted DSL device and cable specification, not the G3\/G5\/G12.x +5 V optical table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake \/ thermal \/ power\u003c\/td\u003e\n\u003ctd\u003eTrace the separate circuits for the complete order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue channels\u003c\/td\u003e\n\u003ctd\u003eDo not connect a classic-HIPERFACE sine\/cosine adapter to a DSL pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eRead connector drawings in their stated contact-side view and verify numbering, keyway, male\/female contacts and shell position. Check continuity with both ends isolated before applying feedback power. Photograph and label any repaired or custom loom so the test report identifies the actual route used.\u003c\/p\u003e\n\u003cp\u003eKeep motor phase conductors, brake supply, fan supply, protective earth, thermal circuits, encoder supply\/return and signal pairs distinct. Do not infer a pinout from wire colour, a shared connector shell, another manufacturer's motor or an electrically different feedback option. If a diagram caption and an order table disagree, resolve the actual fitted branch before energizing it.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"cables\"\u003e\u003ch2\u003eTest leads, internal loom and machine cable\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eConnection layer\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat must be established\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect encoder plug\u003c\/td\u003e\n\u003ctd\u003eExact device connector and compatible bench lead; not automatically a motor-bulkhead connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor internal loom\u003c\/td\u003e\n\u003ctd\u003eContinuity, shielding, strain relief and any changes made during earlier repairs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor feedback \/ hybrid bulkhead\u003c\/td\u003e\n\u003ctd\u003eCorrect socket, contact view, branch and separate power\/brake\/thermal circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine cable\u003c\/td\u003e\n\u003ctd\u003eBoth endpoint pinouts, length\/routing, drag-chain damage and shield termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive \/ tester end\u003c\/td\u003e\n\u003ctd\u003eCorrect installed selection, supply module and interface-specific lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eA device that reads correctly with a direct plug but fails through the motor can point to the internal loom or bulkhead route. A device that works at the motor but fails through the machine harness requires an endpoint-by-endpoint cable check. Document which layer was bypassed; do not report a complete motor or machine harness as proven from a direct encoder test.\u003c\/p\u003e\n\u003cp\u003eUse the actual DSL-compatible lead and TI-5106 setup for the identified branch. A classic-HIPERFACE 1 Vpp module or an unverified hybrid connector cannot be substituted because both products use the word HIPERFACE.\u003c\/p\u003e\n\u003cp\u003eNo complete machine-cable part number or universal lead is assigned to every configuration in this guide. Select or document the cable only after the complete motor\/encoder labels and both connector endpoints are known.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003eDiagnostic symptoms and useful comparisons\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eReported symptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eEvidence to collect before changing parts\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo position \/ no communication\u003c\/td\u003e\n\u003ctd\u003eSupply\/return, selected protocol, device identity and isolated cable continuity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition changes but drive faults remain\u003c\/td\u003e\n\u003ctd\u003eStatus codes, configuration, motor-data interpretation and phase\/alignment relationship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent or noisy behaviour\u003c\/td\u003e\n\u003ctd\u003eConnector contact, strain\/routing, shield integrity and signal quality through each cable layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncorrect direction or scaling\u003c\/td\u003e\n\u003ctd\u003eRecorded device direction, selected protocol\/word format and drive scaling; do not rewrite offsets to hide it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiturn value unexpected\u003c\/td\u003e\n\u003ctd\u003eFitted MT identity, documented turn range and incoming count across a controlled turn boundary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault appeared after removal\u003c\/td\u003e\n\u003ctd\u003eOriginal reference marks, mechanical holder\/shaft relationship, supported offsets and before\/after reports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eCompare one identified path at a time: direct encoder, internal loom, motor bulkhead, then machine cable\/drive. Retain the original symptom, fault codes and setup with each result. An isolated cable fault, an unsupported test selection and a damaged encoder can present a similar initial symptom.\u003c\/p\u003e\n\u003cp\u003eFor DSL, use the supported digital status and readback. The absence of an external analogue waveform is not a fault on a two-wire digital link.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, offsets and memory preservation\u003c\/h2\u003e\n\u003cp\u003eCapture incoming mechanical reference, supported electrical\/commutation angle, offsets, position\/status, identity and readable memory before removal or writes. Save a report that identifies the full motor, encoder, fixture, lead and selected software configuration. Preserve valid incoming data as the reference for any approved repair.\u003c\/p\u003e\n\u003cp\u003eAfter mechanical work, check the fitted encoder's mounting and signal quality before interpreting an angle. A wrong cable\/selection or an unstable mechanical fit can make an otherwise valid offset appear incorrect. Do not copy an angle, memory image or motor profile from another motor merely because its frame or protocol matches.\u003c\/p\u003e\n\u003cp\u003eOnly use memory or electronic-alignment functions that are explicitly supported for the identified encoder and motor application. A generic device-level capability does not prove that every manufacturer's memory layout is understood.\u003c\/p\u003e\n\u003cp\u003eIf the original relationship or data is unavailable, define a motor-specific recovery method from documented motor\/feedback information and the installed test system. This guide does not prescribe a universal lock-up angle, firmware threshold, phase convention or replacement memory file. Record the before\/after evidence and the exact change performed.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eService scope, replacement and availability\u003c\/h2\u003e\n\u003cp\u003eThis is a technical-guide\/service listing for KEBA \/ LTi LST-190-2, not a claim that a complete motor, encoder, brake, fan or cable is held in stock. Parts and service scope follow review of the full fitted labels, connector photos, fault report and required operating conditions.\u003c\/p\u003e\n\u003cp\u003eA replacement decision must compare interface, absolute\/analogue behaviour, supply, mounting, shaft\/holder, connector route, thermal\/brake options, supported motor data and drive compatibility. A motor-base match alone does not establish a drop-in replacement. Catalogue inclusion does not prove current production, exact-order availability, turnaround or certification.\u003c\/p\u003e\n\u003cp\u003eProvide clear label and connector photographs plus the reported symptom and any previous repair changes for a scoped UAE site visit or send-in evaluation. The service quotation can then identify the assessment, repair, alignment or installation work and any parts that require confirmation.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eApplications and practical service enquiries\u003c\/h2\u003e\n\u003cp\u003eThe selected 190 frame\/family and 32 Nm catalogue reference place this guide in the identified motor range; they do not rate a new machine duty. Typical enquiries concern feedback faults, connector\/loom repair, motor replacement identification, reinstallation after mechanical work and preservation of existing alignment\/data.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompare the exact motor and feedback branch during a repair intake.\u003c\/li\u003e\n\u003cli\u003eDocument a cable-versus-encoder investigation before replacing an otherwise serviceable assembly.\u003c\/li\u003e\n\u003cli\u003ePrepare an installation or reinstallation visit with complete labels, drive details and machine reference.\u003c\/li\u003e\n\u003cli\u003eAssess an identified replacement against the actual shaft, cooling, brake, connector and data requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUse the documents below and the exact fitted-label evidence when comparing another interface or motor base.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest installation, repair or alignment assessment\u003c\/a\u003e and include reference \u003cstrong\u003eTCG1652\u003c\/strong\u003e.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.keba.com\/download\/x\/78cef3992f\/0814-25b_lsn-lst-motor_kat_en.pdf\"\u003eKEBA LSN\/LST order catalogue 0814.25B.8-00, 11\/2022\u003c\/a\u003e — \u003ca href=\"https:\/\/device.report\/m\/56857c9a0a12baa63b826e97ac8d73075a8850168e372b961d65c9dab805164b\"\u003ereadable reproduction of the OEM catalogue\u003c\/a\u003e. KEBA LSN\/LST catalogue, motor table p.100. Mechanical reference: p.101.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/ti-5106-sick-hiperface-dsl-hardware-adapter-module\/\"\u003eMitchell TI-5106 DSL hardware and installed-edition scope\u003c\/a\u003e. Verify the fitted device and exact motor-specific cable.\u003c\/li\u003e\n\u003cli\u003eKEBA encoder\/order tables: pp.14 and 66–67; G7.2x hybrid connection reference p.116; frame drawing p.101. Do not import the p.115 optical-encoder supply column into this DSL scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese references support the scoped family and documented options. The complete fitted order and actual device revision determine the final wiring, envelope, software selection and service method. Keep the source edition\/page, nameplate photos and measured setup with the report so a later technician can reproduce the identification.\u003c\/p\u003e\n\u003cp\u003eThe cover is a branded service illustration with concise headings. It is not an OEM dimensional drawing or proof of the exact motor\/encoder installed in a machine.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"faq\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs this a complete factory motor order?\u003c\/h3\u003e\n\u003cp\u003eNo. KEBA \/ LTi LST-190-2 is a guide grouping. Match all winding\/speed, shaft, mounting, cooling, brake, feedback and custom-order fields on the actual plates.\u003c\/p\u003e\n\u003ch3\u003eWhy are singleturn and multiturn on one page?\u003c\/h3\u003e\n\u003cp\u003eThey share the scoped interface. Device labels, resolution, revolution range, mechanical variants and supported setup remain distinguished in the comparison table.\u003c\/p\u003e\n\u003ch3\u003eCan I use another motor's cable or test selection?\u003c\/h3\u003e\n\u003cp\u003eOnly after the actual device, supply, complete endpoint wiring and installed support are established. A shared shell, frame or protocol name is not enough.\u003c\/p\u003e\n\u003ch3\u003eDoes feedback testing prove a motor-run setup?\u003c\/h3\u003e\n\u003cp\u003eNo. Exact motor parameters, fixture\/load, brake and phase\/alignment conventions require their own motor-specific run-test approval.\u003c\/p\u003e\n\u003ch3\u003eCan the original alignment and data be preserved?\u003c\/h3\u003e\n\u003cp\u003eCapture available incoming identity, mechanical reference, supported angles\/offsets and readable data before removal or writes. Recovery after missing data requires a defined motor-specific method.\u003c\/p\u003e\n\u003ch3\u003eHow do I request service?\u003c\/h3\u003e\n\u003cp\u003eSend full motor and encoder labels, connector photographs, drive details, fault symptoms and previous repair changes with TCG1652. Installation, repair, alignment and site\/send-in scope follow identification.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eSend a service enquiry for TCG1652\u003c\/a\u003e.\u003c\/p\u003e\u003c\/section\u003e","brand":"KEBA\/LTi","offers":[{"title":"Default Title","offer_id":51295431524517,"sku":"TCG1652","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/tcg1652-keba-lti-lst-190-2-hiperface-dsl-singleturn-multiturn-feedback-technical-guide-cover.jpg?v=1795434015","url":"https:\/\/www.sparefaber.com\/de\/products\/keba-lti-lst-190-2-hiperface-dsl-singleturn-multiturn-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}