{"product_id":"ltn-re-21-1-a05","title":"LTN RE-21-1-A05 Resolver  | Technical Guide| Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eResolver fault, wrong angle or a motor that trips after a rebuild?\u003c\/strong\u003e SpareFaber can visit your UAE site to check the RE-21-1-A05 windings, the motor harness, drive excitation and the installed alignment. Send the motor and resolver together for bench checks of the assembled fit and offset.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"LTN RE-21-1-A05 Resolver technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the resolver label, exact motor and drive codes, the alarm and when it occurs. Include photos of the mounting register and any motor bulkhead connector. A photo of the old wire terminations is particularly helpful after a rewire. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA \u003cstrong\u003eMitchell TI-5000JX\u003c\/strong\u003e can test this class of resolver using Generic Resolvers and its built-in resolver hardware. A qualified bench technician can set the approved excitation for the exact resolver, check angle and direction, and inspect sine and cosine envelopes with the \u003cstrong\u003eTI-3011\u003c\/strong\u003e breakout and an appropriate differential measurement setup.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003eTI-3000JX\u003c\/strong\u003e Generic Resolver run test requires the motor pole count, 1X resolver setting, phase direction and a measured angle under the documented lockup reference. It requires a guarded fixture, suitable motor and verified commutation. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26578514023963-Generic-Resolvers\"\u003eMitchell resolver checkout\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26594756325275-Generic-Resolvers\"\u003eMitchell Generic Resolver run setup\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eLTN RE-21-1-A05 Resolver technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eLook for the complete \u003cstrong\u003eRE-21-1-A05\u003c\/strong\u003e marking. RE-21 identifies the frame family. The middle 1 corresponds to one pole pair in LTN’s A05 data. The A05 suffix selects the winding and electrical specification, which differs from other one-pole-pair RE-21 parts.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"LTN RE-21 winding variants, room-temperature resistance\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eLTN RE-21 winding variants, room-temperature resistance\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFull LTN code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePole pairs \/ ratio\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eExcitation winding\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eEach output winding\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRE-21-1-A04\u003c\/th\u003e\n\u003ctd\u003e1 \/ 0.5 ±10%\u003c\/td\u003e\n\u003ctd\u003e90 Ω ±10%\u003c\/td\u003e\n\u003ctd\u003e72 Ω ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRE-21-1-A05\u003c\/th\u003e\n\u003ctd\u003e1 \/ 0.5 ±10%\u003c\/td\u003e\n\u003ctd\u003e48 Ω ±10%\u003c\/td\u003e\n\u003ctd\u003e31 Ω ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRE-21-1-A06\u003c\/th\u003e\n\u003ctd\u003e1 \/ 0.5 ±10%\u003c\/td\u003e\n\u003ctd\u003e61 Ω ±10%\u003c\/td\u003e\n\u003ctd\u003e53 Ω ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRE-21-1-A07\u003c\/th\u003e\n\u003ctd\u003e1 \/ 1.0 ±10%\u003c\/td\u003e\n\u003ctd\u003e90 Ω ±10%\u003c\/td\u003e\n\u003ctd\u003e260 Ω ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eA matching frame and pole count are only part of the replacement check. Compare the winding and the motor’s fit and excitation specification. \u003ca href=\"https:\/\/www.ltn-servotechnik.com\/fileadmin\/imported\/products\/RE-21_2025_einzel.pdf#page=2\"\u003eLTN electrical selection table (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.sparefaber.com\/products\/ltn-resolver-re-21-1-a05-resolver-size-21-hollow-12-7-mm-1-pole-pair\"\u003eMatching SpareFaber spare\u003c\/a\u003e\u003c\/p\u003e\n\u003cfigure style=\"max-width: 24rem; margin: 1rem 0;\"\u003e\u003cimg src=\"https:\/\/www.sparefaber.com\/cdn\/shop\/files\/LTNRE-21-1-A05TopViewFramesize21.jpg?v=1785735667\u0026amp;width=3840\" alt=\"SpareFaber LTN RE-21-1-A05 resolver showing the rotor bore, stator, leads and identification label\" loading=\"lazy\" style=\"width: 100%; height: auto;\"\u003e\u003cfigcaption\u003eRE-21-1-A05 from SpareFaber’s matching spare listing. Check the label and bore on your unit.\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eLTN still provides RE-21 product information that names A05. Manufacturer production and an exact approved successor remain unconfirmed. SpareFaber has a separate catalogue listing for the matching spare. Reviewed 7 November 2026. \u003ca href=\"https:\/\/www.ltn-servotechnik.com\/fileadmin\/imported\/products\/RE-21_2025_einzel.pdf\"\u003eLTN current RE-21 document (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.sparefaber.com\/products\/ltn-resolver-re-21-1-a05-resolver-size-21-hollow-12-7-mm-1-pole-pair\"\u003eSpareFaber A05 stock listing\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"LTN RE-21-1-A05, RE-21 electrical table and 12.7 mm build\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eLTN RE-21-1-A05, RE-21 electrical table and 12.7 mm build\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring method\u003c\/th\u003e\n\u003ctd\u003ePassive 1X frameless resolver, one electrical angle cycle per shaft turn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExcitation reference\u003c\/th\u003e\n\u003ctd\u003e7 V AC nominal (7 Vrms in the earlier LTN sheet). Current 70 mA ±10% at the 7 V, 4 kHz condition in the linked electrical table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransformation ratio and phase shift\u003c\/th\u003e\n\u003ctd\u003e0.5 ±10%. Carrier phase shift 8° ±3° at the stated 7 V, 4 kHz condition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRoom-temperature winding resistance\u003c\/th\u003e\n\u003ctd\u003ePrimary 48 Ω ±10%. Each secondary 31 Ω ±10%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolver accuracy\u003c\/th\u003e\n\u003ctd\u003e±5 arcminutes with 9 arcminutes spread in the LTN table. The drive adds its own conversion error.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit\u003c\/th\u003e\n\u003ctd\u003eØ12.7 H8 rotor bore on the illustrated drawing. Size 21 family. Select the drawing that matches the recess and stator register.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eComponent limits and leads\u003c\/th\u003e\n\u003ctd\u003e≤20,000 rpm, −55 to +155 °C, minimum 300 mm AWG 24 leads in the linked LTN table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe LTN table’s test conditions and the Parker drive’s excitation are separate. Use the approved motor and drive values in service, and compare RMS and peak-to-peak only after accounting for the waveform. \u003ca href=\"https:\/\/www.ltn-servotechnik.com\/fileadmin\/imported\/products\/RE-21_2025_einzel.pdf\"\u003eLTN drawing and specifications (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.ltn-servotechnik.com\/fileadmin\/imported\/products\/RE_21_EN.pdf\"\u003eEarlier LTN RMS notation (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe rotor slides onto the motor shaft. The stator sits concentrically in the end housing and stays fixed to the motor. Neither part supplies its own bearing. The motor controls rotor position, running clearance and retention. Photograph the rotor orientation and stator location before disassembly.\u003c\/p\u003e\n\u003cp\u003eOn the LTN drawing with the Ø50.77 mm register, the reference shaft is \u003cstrong\u003eØ12.7 g7\u003c\/strong\u003e and the rotor bore is \u003cstrong\u003eØ12.7 H8\u003c\/strong\u003e. LTN publishes several outlines on the same sheet. Compare the recess, stator locating diameter, axial offset and retention details with the original motor. Avoid loading the windings, and route the leads away from rotating parts. Use the exact motor assembly procedure for fasteners, shims or adhesive. \u003ca href=\"https:\/\/www.ltn-servotechnik.com\/fileadmin\/imported\/products\/RE-21_2025_einzel.pdf#page=1\"\u003eLTN resolver mating geometry (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe drive feeds an AC carrier to R1\/R2. The rotor position modulates the same carrier in two outputs. S1\/S3 is the cosine winding and S2\/S4 is sine. At a stationary angle the carrier is still present. The drive demodulates the two channels to calculate angle from their ratio and sign.\u003c\/p\u003e\n\u003cp\u003eIf the pairs are swapped or one pair’s polarity is reversed, the drive can show smooth motion with the wrong angle or direction. Check both output amplitudes over a full safe turn, since a single channel can naturally be near zero at a particular shaft angle.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"LTN standard open leads and Parker PSD1-S X18 resolver option\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eLTN standard open leads and Parker PSD1-S X18 resolver option\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eCircuit\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eLTN leads\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eParker X18 pins\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExcitation R1 \/ R2\u003c\/th\u003e\n\u003ctd\u003eRed\/white \/ black\/white\u003c\/td\u003e\n\u003ctd\u003e4 REF+ \/ 15 REF−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCosine S1 \/ S3\u003c\/th\u003e\n\u003ctd\u003eRed \/ black\u003c\/td\u003e\n\u003ctd\u003e12 COS+ \/ 11 COS−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSine S2 \/ S4\u003c\/th\u003e\n\u003ctd\u003eYellow \/ blue\u003c\/td\u003e\n\u003ctd\u003e8 SIN+ \/ 7 SIN−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eMatch the actual motor harness and connector orientation before termination. The X18 numbers are for the Parker resolver-configured high-density Sub-D input in section 4.6.2. The resolver has no dedicated supply or temperature lead on this six-lead map. The X18 temperature circuit is separate. \u003ca href=\"https:\/\/www.ltn-servotechnik.com\/fileadmin\/imported\/products\/RE-21_2025_einzel.pdf#page=1\"\u003eLTN lead and polarity drawing (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Electromechanical-Europe\/User-Guides\/192-011006_PSD1_InstallationGuide_eng.pdf#page=40\"\u003eParker PSD1-S X18 drawing (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eLTN shows six open AWG 24 PTFE leads, 300 mm on the standard outline. There is no universal motor-end plug on this resolver. Ask the motor manufacturer for the motor-side loom using the exact motor model, connector and serial number. A replacement harness needs three correct pairs, the original polarity, temperature routing where present, and the drive maker’s shield termination. The Parker X18 table applies to the drive end only. \u003ca href=\"https:\/\/www.ltn-servotechnik.com\/fileadmin\/imported\/products\/RE-21_2025_einzel.pdf#page=1\"\u003eLTN open-end leads (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Electromechanical-Europe\/User-Guides\/192-011006_PSD1_InstallationGuide_eng.pdf\"\u003eParker motor feedback connection instructions (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolate first.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eLook and document.\u003c\/strong\u003e Check plug latch, pushed-back pins, oil, foreign material, damaged shielding and strain relief. Look for a shifted stator, rub marks and altered axial spacing after a bearing repair.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the harness separately.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure each winding directly.\u003c\/strong\u003e With the resolver disconnected, use resistance mode across the named pair. At room temperature, 48 Ω ±10% is about 43.2–52.8 Ω on R1\/R2, and 31 Ω ±10% is about 27.9–34.1 Ω on each output. A reading taken through the drive or a cable can obscure the source. Compare both secondary readings and check for unintended links between winding pairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck excitation and output on an approved setup.\u003c\/strong\u003e A qualified person can fit a breakout while isolated and use an appropriate differential scope or resolver tester. Compare the carrier across R1\/R2 and the two return envelopes at the same angle. An ordinary meter can miss or misread a kilohertz carrier. If the drive has excitation but the resolver does not, trace the harness. If the signals are sound at the drive and the shaft reads backward or trips on torque enable, verify polarity, motor phase order and alignment.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eParker specifically lists \u003cstrong\u003eRE-21-1-A05\u003c\/strong\u003e for its PSD1 resolver feedback option. In the PSD1-S section 4.6.2 the X18 drawing gives the drive’s 8 kHz carrier and maximum 9.5 V peak-to-peak excitation. This is a verified receiver application. Confirm the motor code and receiver configuration when selecting replacement parts. \u003ca href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Electromechanical-Europe\/User-Guides\/192-011006_PSD1_InstallationGuide_eng.pdf#page=40\"\u003eParker PSD1-S resolver compatibility and wiring (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eThis passive resolver supplies angle-dependent windings and has no electronic memory to clone. Preserve the old mechanical index and read the drive’s existing offset where documented. Use the motor or drive commissioning procedure to set the new commutation offset and confirm direction. Mitchell’s Generic Resolver run setup uses the angle measured at a +U\/−V lockup reference. That is a bench reference for the approved motor and setup. An exact offset in electrical degrees requires the specific motor, pole count and phase convention. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26594756325275-Generic-Resolvers\"\u003eMitchell angle convention and guarded run setup\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.ltn-servotechnik.com\/fileadmin\/imported\/products\/RE-21_2025_einzel.pdf\"\u003eLTN RE-21 mechanical drawings and electrical data (PDF)\u003c\/a\u003e. Page 1 for dimensions and wiring, page 2 for the A05 winding table.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.ltn-servotechnik.com\/fileadmin\/user_upload\/data\/pdf\/LTN_PB_RESOLVERS_EN_08-2024-online-einzel.pdf\"\u003eLTN frameless resolver catalogue (PDF)\u003c\/a\u003e. See RE-21 for the A04, A05, A06 and A07 variants.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Electromechanical-Europe\/User-Guides\/192-011006_PSD1_InstallationGuide_eng.pdf\"\u003eParker PSD1 installation guide 192-011006N10 (PDF)\u003c\/a\u003e. Sections 4.6.2 and 5.8.2 cover the resolver-configured drive connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26578514023963-Generic-Resolvers\"\u003eMitchell Generic Resolvers\u003c\/a\u003e. Check setup and excitation limits against the exact resolver.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading (Est. 2003]","offers":[{"title":"Default Title","offer_id":51116994887845,"sku":"iuv34","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/LTNRE-21-1-A05ResolverTechnicalGuideServiceVisitforInstallation_Repair_Alignment.jpg?v=1794124927","url":"https:\/\/www.sparefaber.com\/de\/products\/ltn-re-21-1-a05","provider":"SpareFaber","version":"1.0","type":"link"}