{"product_id":"micro-epsilon-wds-1500-p60-cr-p-m4","title":"Micro-Epsilon WDS-1500-P60-CR-P-M4 Draw-Wire Position Sensor | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for WDS-1500-P60 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Micro-Epsilon WDS-1500-P60-CR-P-M4 Draw-Wire Position Sensor technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eAn isolated resistance check or a documented low-energy bench divider can help separate an element fault from wiring or PLC input trouble. Secure the wire and use a controlled displacement fixture. Treat any separate Mitchell capability as unverified for this passive sensor.\u003c\/p\u003e\n\u003ch2\u003eMicro-Epsilon WDS-1500-P60-CR-P-M4 Draw-Wire Position Sensor technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eWDS-1500-P60-CR-P-M4\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWDS-1500-P60-CR-P-M4\u003c\/th\u003e\n\u003ctd\u003e1,500 mm P60 draw-wire assembly. CR is fixed radial cable. Match the M4 wire attachment.\u003c\/td\u003e\n\u003ctd\u003eP is a passive potentiometric divider, with white\/brown\/green leads.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWDS P60 SR U \/ I\u003c\/th\u003e\n\u003ctd\u003eSeparate family output options with a built-in radial plug.\u003c\/td\u003e\n\u003ctd\u003eActive voltage or current output. Use the separate SR wiring and power requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWE-1500-M4\u003c\/th\u003e\n\u003ctd\u003eManufacturer-documented 1,500 mm mechanical wire extension with M4 connection.\u003c\/td\u003e\n\u003ctd\u003eAccessory for the application described by Micro-Epsilon. It carries mechanical displacement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eMicro-Epsilon identifies this order code in its application note and documents the P60 family. Confirm current production and availability for the exact M4 build.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for WDS-1500-P60-CR-P-M4\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for WDS-1500-P60-CR-P-M4\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStroke\u003c\/th\u003e\n\u003ctd\u003e1,500 mm for this sensor order. Use the specified usable travel and end-stop geometry.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e1 kΩ ±10% passive potentiometric divider in the P output family. Use the sensitivity printed on the label.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExcitation\u003c\/th\u003e\n\u003ctd\u003eManual lists maximum 32 V DC at the 1 kΩ \/ max. 1 W condition and wiper current up to 3 mA. Design within the actual resistance, power and temperature constraints.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical lead\u003c\/th\u003e\n\u003ctd\u003eCR fixed radial cable, 1 m per P60 technical table. Follow figure 18 for colours.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical route\u003c\/th\u003e\n\u003ctd\u003eP60 manual allows up to 3° wire misalignment from the outlet axis. Use the prescribed pulley where needed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.micro-epsilon.com\/fileadmin\/download\/manuals\/man--wireSENSOR-P60-P96-P115--de-en.pdf#page=81\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eSecure the sensor to the machine and align the outlet with the first wire run. Fasten the wire using the specified clip or M4 hardware. Use approved pulleys for direction changes and protect the run against abrasion and snagging. Verify that the target stays within the sensor's working stroke at both ends.\u003c\/p\u003e\n\u003cp\u003eThe measuring wire is spring-loaded. Support the moving assembly, secure the wire during handling and let it retract only under control. Keep personnel clear of the line of pull. Inspect pulley wear and sharp bends after the machine is isolated.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eMachine motion pulls a wire from a spring-return drum. The drum moves a potentiometer wiper. The controller supplies a reference across the two end terminals and measures the wiper voltage as a fraction of it. The input must have suitable impedance and the PLC or meter scale must match the sensor and reference. A supply change or cable drop can mimic a displacement error.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse figure 18 for the CR\/P cable and figure 20 for the divider circuit. The active SR variants use different figures.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"WDS P60 CR\/P fixed lead\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eWDS P60 CR\/P fixed lead\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eConductor\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWhite\u003c\/th\u003e\n\u003ctd\u003eExcitation input +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrown\u003c\/th\u003e\n\u003ctd\u003eGround \/ excitation return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGreen\u003c\/th\u003e\n\u003ctd\u003eWiper signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eScreen\u003c\/th\u003e\n\u003ctd\u003eHousing shield as shown in figure 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse the potentiometer as a divider. Keep wiper current within the manual's rating and follow the machine grounding diagram.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThis build uses a fixed electrical lead. Order the controller extension by its documented shield, routing and terminal map. Micro-Epsilon lists \u003cstrong\u003eWE-1500-M4\u003c\/strong\u003e in its telescopic platform example. That is the separate mechanical wire extension. See the manual for approved guide pulleys when the installed routing requires them.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiper value flat or erratic\u003c\/th\u003e\n\u003ctd\u003eWith the sensor disconnected from powered electronics and the wire secured, a qualified technician can check end-to-end element resistance and look for smooth wiper change during controlled travel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput scales incorrectly but moves smoothly\u003c\/th\u003e\n\u003ctd\u003eCompare excitation at the sensor, input loading and PLC calibration against known positions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReading jumps near the same point\u003c\/th\u003e\n\u003ctd\u003eCheck wire routing, pulley friction and the wiper response at that location.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWire slack or slow return\u003c\/th\u003e\n\u003ctd\u003eInspect the route and fastening. Refer suspected drum or spring faults to the approved service procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eMicro-Epsilon documents this exact sensor and WE-1500-M4 extension for synchronized travel monitoring on telescopic platforms. Confirm the actual wire path, brackets and calibration from the machine drawings. The sensor provides position to the machine controller.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSet wire geometry and mechanical stroke, then compare the sensor output at the OEM-defined reference positions. Record input voltage, end values and PLC scaling before changing hardware. Verify calibration after refit using the machine's permitted motion procedure.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.micro-epsilon.com\/fileadmin\/download\/manuals\/man--wireSENSOR-P60-P96-P115--de-en.pdf#page=81\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.micro-epsilon.com\/applications\/industries\/mobile-machines\/synchronization-monitoring-by-draw-wire-sensors\/?sLang=en\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.micro-epsilon.com\/fileadmin\/download\/manuals\/man--wireSENSOR-P60-P96-P115--de-en.pdf#page=64\"\u003eP output electrical ratings\u003c\/a\u003e. Use the CR\/P version and the listed rating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.micro-epsilon.com\/fileadmin\/download\/manuals\/man--wireSENSOR-P60-P96-P115--de-en.pdf#page=82\"\u003ePotentiometer circuit and wiring\u003c\/a\u003e. Use figures 18 and 20 for this fixed-cable passive build.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.micro-epsilon.com\/applications\/industries\/mobile-machines\/synchronization-monitoring-by-draw-wire-sensors\/?sLang=en\"\u003eExact Micro-Epsilon application and wire extension\u003c\/a\u003e. Identifies the full model and WE-1500-M4 accessory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51119421096101,"sku":"TCG109","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/micro-epsilon-wds-1500-p60-cr-p-m4-service-guide.jpg?v=1794148630","url":"https:\/\/www.sparefaber.com\/de\/products\/micro-epsilon-wds-1500-p60-cr-p-m4","provider":"SpareFaber","version":"1.0","type":"link"}