{"product_id":"mitsubishi-electric-hg-sr202-feedback-technical-guide","title":"Mitsubishi Electric HG-SR202 Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eMitsubishi Electric HG-SR202 — 22-bit OEM serial; Mitchell OBA\/OSA18 selection. Use this guide to identify the fitted feedback, separate connection faults from sensor faults and prepare a supported evaluation. SpareFaber can assess an appropriate UAE site visit, installation\/alignment work or send-in bench evaluation after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentify the fitted part\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eSend an enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted part\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"id-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide scope\u003c\/th\u003e\n\u003ctd\u003eMitsubishi Electric HG-SR202 — motor feedback application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback identity\u003c\/th\u003e\n\u003ctd\u003eOBA\/OSA18 tester identity; preserve actual OBA\/OSA24R or fitted label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMain model \/ application identifier\u003c\/th\u003e\n\u003ctd\u003eHG-SR202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor order scope\u003c\/th\u003e\n\u003ctd\u003eOEM standard motor model, without brake or reducer; verify all fitted suffixes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003e22-bit OEM serial; Mitchell OBA\/OSA18 selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting connection\u003c\/th\u003e\n\u003ctd\u003eCMV1-R10P 10-contact feedback connector: TI-5732 only after confirming contact\/key view; two-wire serial data.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: connection before conclusion\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX bench scope\u003c\/th\u003e\n\u003ctd\u003eConditional TI-5000JX scope. 2 kW, 2,000 rpm; 176 mm square flange. Check the standard shaft, power connector and two-wire serial feedback connection. OEM 22-bit specification and Mitchell OBA\/OSA18 tester selection are different descriptions. Do not change the tester selection solely to match the advertised bit count.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead \/ fixture\u003c\/th\u003e\n\u003ctd\u003eCMV1-R10P 10-contact feedback connector: TI-5732 only after confirming contact\/key view; two-wire serial data.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfile \/ module\u003c\/th\u003e\n\u003ctd\u003eOEM 22-bit specification and Mitchell OBA\/OSA18 tester selection are different descriptions. Do not change the tester selection solely to match the advertised bit count.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX motor-run scope\u003c\/th\u003e\n\u003ctd\u003eUse only the documented Mitsubishi serial run path after confirming actual feedback, poles, direction, winding voltage and amplifier current\/speed envelope. These catalogue ratings are not a claim of full-power tester capability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe documented test reference is Mitsubishi HG Series Motors - Melservo J4 Drives — Mitchell HG HG-SR named option; SH-030113ENG-P printed p.7-21, PDF p.190. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eThe linked manufacturer record documents this configuration. Current production, stock and an approved successor for the complete fitted order still require manufacturer confirmation. A historical manual or downloadable CAD drawing does not prove present availability. Match voltage, mounting, shaft, brake, feedback, connector and motor-data requirements before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback technology\u003c\/th\u003e\n\u003ctd\u003e22-bit OEM serial; Mitchell OBA\/OSA18 selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated motor output\u003c\/th\u003e\n\u003ctd\u003e2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e2,000 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor flange\u003c\/th\u003e\n\u003ctd\u003e176 mm square\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShaft diameter \/ tolerance\u003c\/th\u003e\n\u003ctd\u003e35 (+0.010\/0) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot diameter \/ tolerance\u003c\/th\u003e\n\u003ctd\u003e114.3 (0\/-0.025) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower receptacle\u003c\/th\u003e\n\u003ctd\u003eMS3102A22-22P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback receptacle\u003c\/th\u003e\n\u003ctd\u003eCMV1-R10P, 10 contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard drawing\u003c\/th\u003e\n\u003ctd\u003eSH-030113ENG-P printed p.7-21, PDF p.190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrder scope\u003c\/th\u003e\n\u003ctd\u003eStandard motor without electromagnetic brake or reducer; confirm any additional fitted suffix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard motor mass\u003c\/th\u003e\n\u003ctd\u003e11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eService values\u003c\/th\u003e\n\u003ctd\u003eEncoder coupling dimensions, exact pin map and tightening torque require the fitted assembly drawing. No value is inferred from a related motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe 22-bit figure is the OEM encoder specification. Mitchell names OBA\/OSA18 as the test selection for HG-SR, HG-JR, HG-RR and HG-UR. Preserve both descriptions instead of treating them as contradictory part numbers. Two-wire describes the serial data connection, not the entire motor cable or a physical A\/B\/Z output.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming shaft datum, pilot, bolt pattern, rear clearance, cable exit and retaining arrangement before removal. Use the exact drawing for tolerances and fastening. Do not infer encoder coupling dimensions or tightening torque from the motor flange size. Inspect looseness, bearing play, debris and moisture before disturbing the feedback attachment. Use the exact HG-SR202 drawing, not the adjacent model on the same page. The 35 (+0.010\/0) mm shaft and 114.3 (0\/-0.025) mm pilot determine coupling and locating fit; the 176 mm flange dimension alone is insufficient. Check shaft projection, bolt-circle dimension and connector clearance on the linked drawing. A similar power rating in another HG family does not establish the same shaft or pilot. \u003c\/p\u003e\n\u003cp\u003eHG-SR202 is the standard 2 kW, 2,000 rpm motor with a 176 mm square flange. The exact standard drawing identifies a 35 (+0.010\/0) mm shaft, 114.3 (0\/-0.025) mm pilot and MS3102A22-22P power receptacle. Preserve every additional nameplate suffix; the braked or geared version has a separate outline.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eKeep motor power, protective earth, feedback, temperature sensing and any holding brake as separate circuits. Establish contact numbering, keying, gender and whether the drawing shows the mating face or wire side. Do not infer a pin map from a connector shell. This standard outline shows MS3102A22-22P for motor power and CMV1-R10P for feedback. Use the TI-5732 10-contact DDK drawing only after matching the actual feedback connection. HG feedback uses the newer two-wire serial data arrangement; the older four-wire Mitsubishi data cable is not a substitute.\u003c\/p\u003e\n\u003cp\u003eStarting connection for this guide: CMV1-R10P 10-contact feedback connector: TI-5732 only after confirming contact\/key view; two-wire serial data.. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eRecord the internal encoder-to-motor loom separately from the external machine cable and test fixture. The internal loom part number is not established by the motor model alone. Obtain the assembly drawing and both connector faces. Match cable length, shielding, temperature rating and fixed or flexing duty to the installation; a Mitchell test lead is not an OEM replacement cable.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIsolation and measurement conditions\u003c\/summary\u003e\u003cp\u003eSecure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity\/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"fault-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIdentify before testing\u003c\/th\u003e\n\u003ctd\u003eHG-SR202 is the standard 2 kW, 2,000 rpm motor with a 176 mm square flange. The exact standard drawing identifies a 35 (+0.010\/0) mm shaft, 114.3 (0\/-0.025) mm pilot and MS3102A22-22P power receptacle. Preserve every additional nameplate suffix; the braked or geared version has a separate outline.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent fault with cable movement\u003c\/th\u003e\n\u003ctd\u003eAfter isolation and disconnection at both ends, inspect flex points, pin engagement, contamination and previous repairs. Compare continuity and unintended shorts with the exact diagram, allowing for intentional shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo serial data or unstable position\u003c\/th\u003e\n\u003ctd\u003eConfirm the profile, low-voltage supply at the correct boundary and mating-face pin assignment. Compare the test fixture with the actual motor connector; a plausible connector fit does not prove electrical compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback reads but the drive rejects it\u003c\/th\u003e\n\u003ctd\u003eRecord the original alarm and check exact motor identity, stored data requirements, direction, mechanical attachment and the supported signal paths. A reset is not proof of a compatible replacement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReplacement dimensions look close\u003c\/th\u003e\n\u003ctd\u003eCompare the exact model, shaft, pilot, brake, seal, cooling and connector options above with the linked drawing before ordering or removing the original assembly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and memory\u003c\/h2\u003e\n\u003cp\u003ePreserve the original mechanical reference, motor phase convention, direction and readable drive data before disassembly. Use the fitted motor and encoder service procedure for replacement. Communication alone does not prove correct alignment or machine origin. Select the verified OBA\/OSA18 test identity for this HG family even when the fitted label says OBA\/OSA24R or the OEM specification says 22-bit. Preserve incoming identity and motor-specific calibration. Supported motor-run work requires the documented serial profile and successful setup\/debug checks with the exact winding and amplifier limits; the motor rating is not the tester output rating.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eHG-SR · 2 kW · 2000 rpm · 176 mm square flange. HG-SR202 is the standard 2 kW, 2,000 rpm motor with a 176 mm square flange. The exact standard drawing identifies a 35 (+0.010\/0) mm shaft, 114.3 (0\/-0.025) mm pilot and MS3102A22-22P power receptacle. Preserve every additional nameplate suffix; the braked or geared version has a separate outline.\u003c\/p\u003e\n\u003cp\u003eA matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/22516936684699-Mitsubishi-HG-Series-Motors-Melservo-J4-Drives\" target=\"_blank\" rel=\"noopener\"\u003eMitsubishi HG Series Motors - Melservo J4 Drives\u003c\/a\u003e — Mitchell HG HG-SR named option; SH-030113ENG-P printed p.7-21, PDF p.190\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/catalog\/servo\/l03058\/l03058engh.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMitsubishi MELSERVO-J4 catalogue\u003c\/a\u003e — Use the stated family, option and document revision only\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26664785456539-Mitsubishi-Motors\" target=\"_blank\" rel=\"noopener\"\u003eMitsubishi Motors\u003c\/a\u003e — Named motor family and feedback option; row locator identifies scope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitsubishielectric.com\/dl\/fa\/document\/manual\/servo\/sh030113\/sh030113engp.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMitsubishi HG servo motor instruction manual SH-030113\u003c\/a\u003e — Use the stated family, option and document revision only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eObtain the complete fitted motor and encoder labels, exact service ID, internal loom, connector mating-face drawing and approved setup. Match the linked OEM document revision; unverified supply, pins, retention fasteners and alignment values remain open.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should accompany a HG-SR202 enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear photographs of the motor and feedback labels, every suffix\/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed Mitchell lead be used as a replacement machine cable?\u003c\/summary\u003e\u003cp\u003eThe lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a successful feedback bench test prove that the motor can be run? \u003c\/summary\u003e\u003cp\u003eUse only the documented Mitsubishi serial run path after confirming actual feedback, poles, direction, winding voltage and amplifier current\/speed envelope. These catalogue ratings are not a claim of full-power tester capability. A complete run assessment also checks motor power, brake, protection and mechanical conditions.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhen does a site visit or send-in evaluation make sense?\u003c\/summary\u003e\u003cp\u003eA site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"related\"\u003e\u003ch2\u003eRelated technical guides\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/sparefaber.com\/products\/mitsubishi-hg-sr-melservo-j4-22-bit-feedback\" target=\"_blank\" rel=\"noopener\"\u003eTCG232 — Mitsubishi Electric HG-SR MELSERVO-J4 22-Bit Serial Feedback\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51153468129445,"sku":"TCG741","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/mitsubishi-electric-hg-sr202-service-guide.jpg?v=1794379498","url":"https:\/\/www.sparefaber.com\/de\/products\/mitsubishi-electric-hg-sr202-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}