{"product_id":"mitsubishi-ohe25k-6-abz-uvw-encoder","title":"Mitsubishi Electric OHE25K-6 ABZ and UVW Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for OHE25K-6 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Mitsubishi Electric OHE25K-6 ABZ and UVW Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eFeedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA matched fixture can compare A\/B phase order, index, and U\/V\/W sector transitions at controlled movement. Confirm TI-5677 and the actual TI-5000JX profile before applying power. Determine TI-3000JX run support separately for the full motor order.\u003c\/p\u003e\n\u003ch2\u003eMitsubishi Electric OHE25K-6 ABZ and UVW Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eOHE25K-6\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cp\u003eManufacturer device order code\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOHE25K-6\u003c\/th\u003e\n\u003ctd\u003eMatch the installed motor, coupling and end-cover drawing.\u003c\/td\u003e\n\u003ctd\u003eABZ position\/index and UVW commutation. Mitsubishi documents this suffix in its drive matrix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOHE25K-85\u003c\/th\u003e\n\u003ctd\u003eA separate suffix. The drive matrix gives no mechanical equivalence.\u003c\/td\u003e\n\u003ctd\u003eSame ABZ+UVW class. Confirm fitted harness and configuration before substitution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOHE25K-ET\u003c\/th\u003e\n\u003ctd\u003eSeparate encoder variant.\u003c\/td\u003e\n\u003ctd\u003eAppears in the spindle section of the same manual. Do not infer identical application or fit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for OHE25K-6\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for OHE25K-6\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd\u003eIncremental A\/B\/Z with separate U\/V\/W commutation tracks, as classified by Mitsubishi.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrive table\u003c\/th\u003e\n\u003ctd\u003eOHE25K-6 and -85 appear as compatible motor-end encoders under MDS-C1-N and MDS-A\/B in the cited table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnector reference\u003c\/th\u003e\n\u003ctd\u003eMitchell lists a 19-pin MS test lead for the HA OHE25K\/OSE5K family. The exact motor bulkhead and key still govern.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOpen specifications\u003c\/th\u003e\n\u003ctd\u003eConfirm resolution, supply range, receiver levels and mounting dimensions from the motor and feedback drawing. The cited compatibility table does not specify them.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/manual\/cnc\/ib1501296%28eng%29\/ib1501296engd.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003ePhotograph the original encoder, rotor coupling, clamp orientation and harness before disturbing them. Look for witness marks, shaft play, an ovalled coupling or a cable trapped by the cover.\u003c\/p\u003e\n\u003cp\u003eThe drive manual identifies a signal type and drive pairing. Use the installed motor’s drawing for shaft dimensions, fastener torque and the disassembly sequence.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eA and B report motion and direction. Z provides a reference event. U, V and W give the drive the commutation sector independently of whether the count channels look healthy. A drive may detect movement while rejecting the starting sector.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eTrace the ABZ path and the UVW path separately on the motor\/drive schematic. Use the correct drawing view at both ends and document any intended shield bonds.\u003c\/p\u003e\n\u003cp\u003eAn exact OHE25K-6 contact, colour and supply map for the installed motor remains open. Do not derive any of these from OHE25K-85, a plug shell or a high-speed serial Mitsubishi lead.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eMitchell’s public index lists TI-5677 for the Mitsubishi HA-series OHE25K\/OSE5K ABZ\/UVW family and 19-pin MS connection. This is a tester lead. Obtain the internal encoder-to-bulkhead and machine feedback loom numbers from the motor and drive labels.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo count or direction change\u003c\/th\u003e\n\u003ctd\u003eIsolate the harness and check the A\/B paths, then verify receiver configuration and signal format under an approved test.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGood A\/B but fault at starting\u003c\/th\u003e\n\u003ctd\u003eCheck U\/V\/W sequencing against the exact motor documentation, alignment history and coupling slip.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault changes with cover fitted\u003c\/th\u003e\n\u003ctd\u003eInspect strain relief, pin retention and internal cable routing. Compare disconnected harness results with the cover removed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eStart from the Mitsubishi motor nameplate and full MDS drive model. Mitsubishi’s MDS-C1\/CH-N manual separates ABZ+UVW, ABZ plus low-speed serial, and high-speed serial motor feedback.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eBefore removal document the original mechanical relationship, then use the exact motor procedure to establish the rotor-to-UVW reference. A stable count and index do not prove commutation timing.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/manual\/cnc\/ib1501296%28eng%29\/ib1501296engd.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Section 1.1.4 identifies the OHE25K-6 and OHE25K-85 as ABZ+UVW motor-end encoders and scopes drive compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitsubishielectric.com\/fa\/products\/cnt\/cnc\/\"\u003eManufacturer reference\u003c\/a\u003e. Mitsubishi CNC product and support index. The linked legacy manual documents the exact OHE25K-6 reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\"\u003eMitchell manufacturer cable index\u003c\/a\u003e. The Mitsubishi section lists TI-5677 for the documented HA-series family.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51126567960741,"sku":"TCG148","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/mitsubishi-ohe25k-6-abz-uvw-encoder-service-guide.jpg?v=1794221097","url":"https:\/\/www.sparefaber.com\/de\/products\/mitsubishi-ohe25k-6-abz-uvw-encoder","provider":"SpareFaber","version":"1.0","type":"link"}