{"product_id":"nidec-avtron-av685n1e8y8yc000","title":"Nidec Avtron AV685N1E8Y8YC000 Dual-Output Incremental Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for AV685 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Nidec Avtron AV685N1E8Y8YC000 Dual-Output Incremental Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eCheck A\/B and marker at each documented interface with compatible instrumentation. When one path reads normally, diagnose the other at its connector and again at the receiver. Account for shared power or wiring before treating both paths as independent.\u003c\/p\u003e\n\u003ch2\u003eNidec Avtron AV685N1E8Y8YC000 Dual-Output Incremental Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eAV685N1E8Y8YC000\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAV685N1E8Y8YC000\u003c\/th\u003e\n\u003ctd\u003eN standard temperature, 1 threaded rod tether, E end-shaft mount.\u003c\/td\u003e\n\u003ctd\u003eTwo 8Y high-power HX modules at 1024 ppr each. C is the MS plug and conduit adapter option. 000 adds no modification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAV685 mounting option T\u003c\/th\u003e\n\u003ctd\u003eThrough-shaft housing configuration. Check its drawing and clearance.\u003c\/td\u003e\n\u003ctd\u003eSelect output modules and connector independently.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAV685 line driver option 9\u003c\/th\u003e\n\u003ctd\u003eMount selected separately.\u003c\/td\u003e\n\u003ctd\u003eFixed 5 V output option. Check receiver thresholds before replacing an option 8 module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for AV685N1E8Y8YC000\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for AV685N1E8Y8YC000\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMount\u003c\/th\u003e\n\u003ctd\u003eEnd-shaft AV685, nominal 1⅛ in hollow shaft per model page, 12 in threaded tether B32809.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput selection\u003c\/th\u003e\n\u003ctd\u003eLeft and right 8Y, each 1024 ppr. Manufacturer selection table gives option 8 as 5–24 V in and 5–24 V out.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003eOption C is a 10-contact MS-style connection with mating plug and flex conduit adapter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003eTemperature option N is −20 to +80 °C. Enclosure series rating IP66 subject to the specified assembly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.nidec-avtronencoders.com\/on-demand-datasheet\/21?model=AV685.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe hollow bore sits over the machine shaft. The tether prevents the housing from following the shaft. Match the end-shaft hardware and tether travel to the installation manual. An incorrectly anchored tether can load the housing as the shaft moves axially. Check for loose clamps and unsupported conduits while isolated.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eTwo magnetic incremental modules report movement independently. The receivers determine direction and speed from A\/B phase and use the marker if configured. Treat each module as its own path through its supply, connector, cable and receiver. Compare the two counts over the same approved motion before attributing a mismatch to the shaft.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"AV685 option C MS connection\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eAV685 option C MS connection\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction group\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eContacts in the Avtron option-C wiring figure\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower common \/ supply\u003c\/th\u003e\n\u003ctd\u003eA \/ B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase A pair\u003c\/th\u003e\n\u003ctd\u003eD and G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase B pair\u003c\/th\u003e\n\u003ctd\u003eE and H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMarker pair\u003c\/th\u003e\n\u003ctd\u003eC and I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlarm reference \/ output\u003c\/th\u003e\n\u003ctd\u003eF \/ J, use the approved alarm circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse the manual's differential wiring figure for true and complementary orientation, and inspect the key and contact letters before mating. Read the correct figure for each installed module. Use the manufacturer's grounding guidance and avoid linking the two supplies or commons without the machine schematic.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eOption C includes the mating MS plug and flex conduit adapter. Verify the connector build and wiring on both sides. The manufacturer publishes distinct MS and alternative pinout options. Order a compatible plug or harness by the complete option and application drawing.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOnly one receiver drops out\u003c\/th\u003e\n\u003ctd\u003eCompare its local supply, module status, MS contacts and receiver input with the working path.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoth lose counts together\u003c\/th\u003e\n\u003ctd\u003eCheck common shaft fit, tether, runout and the shared machine supply or routing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEncoder shows an alarm\u003c\/th\u003e\n\u003ctd\u003eCapture LED and alarm state and inspect the mechanical and electrical conditions in the manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse on drives with a compatible heavy-duty hollow-shaft mount and separately verified receiving inputs. The exact code is corroborated by a supplier listing and decoded against Avtron's manufacturer selection table.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eUse the installation drawing for shaft engagement and tether alignment. Retain receiver count, direction and marker settings, then verify both paths after refitting.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.nidec-avtronencoders.com\/on-demand-datasheet\/21?model=AV685.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.nidec-avtronencoders.com\/encoders\/incremental-encoders\/av685\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.nidec-avtronencoders.com\/wp-content\/uploads\/2022\/07\/av685smartachiii003.pdf\"\u003eManufacturer installation and wiring manual\u003c\/a\u003e. Use the option-C MS differential drawing and alarm wiring diagrams.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.nidec-avtronencoders.com\/encoders\/incremental-encoders\/av685\"\u003eProduct page and current selection table\u003c\/a\u003e. Check which mechanical, driver and connector options are fitted.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/intrial.com.pe\/producto\/intrial\/intrial-automatizacion-industrial\/intrial-encoders\/intrial-encoder-magneticos\/encoder-magnetico-severe-mill-duty-hollow-shaft-1024-ppr-5-24v-in-5-15v-out-1024-ppr-av685n1e8y8yc000-avtron\/\"\u003eExact code corroboration\u003c\/a\u003e. Supplier listing establishes the configured code. Use the manufacturer selection table for the electrical rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51119296184485,"sku":"TCG84","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/NidecAvtronAV685N1E8Y8YC000Dual-OutputIncrementalEncoder.jpg?v=1794161535","url":"https:\/\/www.sparefaber.com\/de\/products\/nidec-avtron-av685n1e8y8yc000","provider":"SpareFaber","version":"1.0","type":"link"}