{"product_id":"omron-e6c3-cwz5gh-1024pr-1m","title":"OMRON E6C3-CWZ5GH 1024 P\/R Complementary Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for E6C3-CWZ5GH installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"OMRON E6C3-CWZ5GH 1024 P\/R Complementary Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA qualified test on the correct supply and load can verify 1,024 A-channel periods per turn, A\/B phase, Z and output levels. Follow the datasheet for circuit limits. Confirm exact Mitchell test profile and adapter if considering that equipment.\u003c\/p\u003e\n\u003ch2\u003eOMRON E6C3-CWZ5GH 1024 P\/R Complementary Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eE6C3-CWZ5GH 1024P\/R 1M\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eE6C3-CWZ5GH 1024P\/R 1M\u003c\/th\u003e\n\u003ctd\u003eØ50 mm body, 8 mm shaft, 1 m integral shielded lead.\u003c\/td\u003e\n\u003ctd\u003e1,024 P\/R, 12–24 V DC nominal, complementary A\/B\/Z outputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eE6C3-CWZ5GH 1024P\/R 2M\u003c\/th\u003e\n\u003ctd\u003eSame family fit with 2 m cable.\u003c\/td\u003e\n\u003ctd\u003eSame output and resolution. Verify the actual installed lead length.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eE6C3-CWZ3XH family\u003c\/th\u003e\n\u003ctd\u003eSimilar family body. Read the exact resolution and lead on the label.\u003c\/td\u003e\n\u003ctd\u003eRS-422A line-driver version. Separate signal and supply requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for E6C3-CWZ5GH 1024P\/R 1M\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for E6C3-CWZ5GH 1024P\/R 1M\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003eNominal 12–24 V DC. Datasheet limits 12 V −10% to 24 V +15%. Check ripple limit in the ratings table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSignals\u003c\/th\u003e\n\u003ctd\u003eA\/B quadrature and Z index, complementary output circuit. 1,024 pulses per revolution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e125 kHz maximum response frequency, 65 kHz when using phase Z reset, as specified in the data sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting \/ speed\u003c\/th\u003e\n\u003ctd\u003eØ50 mm body, Ø8 mm shaft, 5,000 rpm mechanical maximum. Apply the lower electrical or mechanical limit for the application.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLead\u003c\/th\u003e\n\u003ctd\u003e1 m integral shielded cable. The 2M order code uses a 2 m lead.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.ia.omron.com\/data_pdf\/cat\/e6c3-c_ds_e_7_3_csm495.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the E6C3-C family drawing for the pilot, shaft projection, shaft flat and mounting hole positions. OMRON lists E69-C08B as an optional coupling. Check shaft alignment, loads and clearance before assembly. OMRON's phase Z figure shows its relation to the shaft flat for the specified mounting view.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe optical encoder outputs A and B pulses with a relative phase shift, plus a Z index. The CWZ5GH has a complementary output circuit that actively drives one wire per channel. The CWZ3XH line-driver family uses a different electrical circuit and extra complementary signal wires. Set the receiver for the actual CWZ5GH levels and input mode.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse page 3, Complementary Output Model, for the CWZ5GH integral lead. These are encoder wire colours. Verify the assignment at any machine connector against the OEM schematic.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"CWZ5GH integral lead\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCWZ5GH integral lead\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eWire\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrown\u003c\/th\u003e\n\u003ctd\u003eSupply +Vcc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBlue\u003c\/th\u003e\n\u003ctd\u003e0 V common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBlack\u003c\/th\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWhite\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOrange\u003c\/th\u003e\n\u003ctd\u003eZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eScreen\u003c\/th\u003e\n\u003ctd\u003eFollow the machine drawing. OMRON states the cable screen is isolated from internals and case.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe order suffix specifies the integral cable length. Use 1M or 2M according to the application. For an external extension, verify the wire map, receiver thresholds, shielding and permitted cable length before connecting. Obtain the machine connector part number from the equipment drawing.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAll signals missing\u003c\/th\u003e\n\u003ctd\u003eCheck loaded voltage and the common reference. Inspect the coupling for slip or a stationary encoder shaft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOne phase missing or count becomes erratic at speed\u003c\/th\u003e\n\u003ctd\u003eCompare A and B with the correct input load. Check lead strain and interference, then compare pulse frequency with the receiving input limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZ unavailable when homing\u003c\/th\u003e\n\u003ctd\u003eCheck the orange wire and actual Z pulses during a controlled turn. Confirm that the configured reset mode respects the specified frequency.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse with a suitable incremental counter, drive or PLC input on machinery. Confirm complementary output compatibility, pulse count mode and the shaft\/coupling fit. Keep machine safety interlocks independent of this diagnostic procedure.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSet the mechanical alignment, then confirm count direction and home position. A reference pulse aids repeatable homing after restart. The standalone encoder does not define a generic servo commutation setting.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.ia.omron.com\/data_pdf\/cat\/e6c3-c_ds_e_7_3_csm495.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.ia.omron.com\/product\/family\/1335\/index_pro_51.html\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.ia.omron.com\/data_pdf\/cat\/e6c3-c_ds_e_7_3_csm495.pdf#page=2\"\u003eRatings and phase Z orientation\u003c\/a\u003e. Compare the CWZ5GH column and shaft view.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.ia.omron.com\/data_pdf\/cat\/e6c3-c_ds_e_7_3_csm495.pdf#page=3\"\u003eCWZ5GH output diagram\u003c\/a\u003e. Use the complementary output model.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.ia.omron.com\/data_pdf\/cat\/e6c3-c_ds_e_7_3_csm495.pdf#page=4\"\u003eMating dimensions and coupling\u003c\/a\u003e. Shows the main encoder and E69-C08B.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118431502501,"sku":"TCG67","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/OMRONE6C3-CWZ5GH1024PRComplementaryEncoder.jpg?v=1794132030","url":"https:\/\/www.sparefaber.com\/de\/products\/omron-e6c3-cwz5gh-1024pr-1m","provider":"SpareFaber","version":"1.0","type":"link"}