{"product_id":"parker-hdy-hj-resolver-feedback-technical-guide","title":"Parker HDY \/ HJ resolver Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eParker HDY \/ HJ resolver — Resolver. Use this guide to identify the fitted feedback, separate connection faults from sensor faults and prepare a supported evaluation. SpareFaber can assess an appropriate UAE site visit, installation\/alignment work or send-in bench evaluation after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentify the fitted part\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eSend an enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: connection before conclusion\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX bench scope\u003c\/th\u003e\n\u003ctd\u003eCheck angle and vector on the documented passive-resolver path. Verify excitation, winding pairs and fixture before connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead \/ fixture\u003c\/th\u003e\n\u003ctd\u003eTI-5907, 12-contact M23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfile \/ module\u003c\/th\u003e\n\u003ctd\u003eResolver input J12; excitation from exact OEM specification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX motor-run scope\u003c\/th\u003e\n\u003ctd\u003eCable-index evidence only for this connection. Exact motor-run profile, power\/brake wiring, motor data and alignment remain unverified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe admission evidence is Mitchell test cable index by manufacturer — PDF page 11, exact TI-5907 row. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted part\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"id-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide scope\u003c\/th\u003e\n\u003ctd\u003eParker HDY \/ HJ resolver — Motor application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback identity\u003c\/th\u003e\n\u003ctd\u003eRecord the fitted feedback maker and complete designation; the named motor family is not a sensor part number.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer MPN \/ full suffix\u003c\/th\u003e\n\u003ctd\u003eHDY \/ HJ is the scoped family\/designation. Match every additional character on the fitted label before ordering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOEM service ID \/ motor order\u003c\/th\u003e\n\u003ctd\u003eNot established for a specific fitted unit. Record the full motor label, feedback option and any OEM service ID separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eResolver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDocumented starting connection\u003c\/th\u003e\n\u003ctd\u003eTI-5907, 12-contact M23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial distinction\u003c\/th\u003e\n\u003ctd\u003eHDY HIPERFACE uses a documented 17-contact connection; this row is resolver-only.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eCurrent production status, exact-order stock and an approved successor have not been confirmed in the cited evidence. Retain the installed label and ask for an exact-order check before selecting a replacement. The linked legacy application document is historical technical evidence, not current availability confirmation.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVerified technical boundary\u003c\/th\u003e\n\u003ctd\u003eKeep resolver excitation and mechanical alignment distinct from HDY HIPERFACE. Obtain the fitted OEM drawing, internal loom and full motor order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply \/ output compatibility\u003c\/th\u003e\n\u003ctd\u003eUse the complete fitted label and its wiring drawing. No universal supply, receiver level or excitation is assigned to this family guide.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExact dimensions, torque and pins\u003c\/th\u003e\n\u003ctd\u003eUse the scoped drawing or request it through the enquiry. Values from another suffix, connector view or motor revision are not substituted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eA resolver uses an excited winding and two position-dependent secondary signals. The tester evaluates their relationship to obtain angle and vector. Excitation voltage, frequency, winding ratio and polarity belong to the exact resolver specification; resistance or a smoothly changing angle alone does not prove correct motor commutation.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003ePhotograph the incoming shaft\/coupling position, locating seat, restraint, fasteners and cable exit before removal. Check accessible looseness, contamination, bearing roughness and signs of rubbing after isolation. Identify whether the assembly has its own bearings, a hollow-shaft clamp or a motor-retained sensor; the exact drawing controls that decision. Do not lever against a sensing disc or apply a torque from a similar-looking model.\u003c\/p\u003e\n\u003cp\u003eREK32\/REK33 are the resolver cable families in the dated Parker catalog; GBK16\/GBK17 are SinCos. Match the motor connector and controller end before selecting TI-5907.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eMap five boundaries separately: the sensor plug or PCB, internal motor loom, motor bulkhead, external machine cable and drive\/tester end. Record connector gender, keying, contact numbering and whether the drawing shows mating or termination side. The documented Mitchell lead is a starting fixture, not a pin map for a handmade adapter. Keep power, temperature, brake, shield and feedback contacts identified individually. The Parker catalog supplies resolver drawings on page 25 and SinCos drawings on page 28. Read the original connector-side diagram; the two feedback paths have different supplies and signal assignments.\u003c\/p\u003e\n\u003cp\u003eStarting connection for this guide: TI-5907, 12-contact M23. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eParker HJ\/HDY catalog pages 25 and 30 identify REK32 as the standard resolver cable and REK33 as its high-flex counterpart. Use the solder-side connector views and complete length suffix in that document. GBK16\/GBK17 belong to the SinCos branch. Internal resolver loom details still require the exact motor assembly drawing.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIsolation and measurement conditions\u003c\/summary\u003e\u003cp\u003eSecure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity\/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"fault-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHDY\/HJ resolver and SinCos cable orders have been mixed\u003c\/th\u003e\n\u003ctd\u003eREK32\/REK33 are the resolver cable families in the dated Parker catalog; GBK16\/GBK17 are SinCos. Match the motor connector and controller end before selecting TI-5907.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault appears when the machine cable moves\u003c\/th\u003e\n\u003ctd\u003eWith the system isolated and both ends disconnected, inspect flex points, connector engagement and repaired sections. Check end-to-end continuity and unintended shorts against the actual pin map, accounting for intentional shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo feedback or intermittent loss at the drive\u003c\/th\u003e\n\u003ctd\u003eAfter label and fixture verification, have a qualified technician check the specified supply or excitation through an approved breakout. Compare at the source and load under the OEM procedure; never assume a voltage from the connector shell.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAngle moves but vector or phase is abnormal\u003c\/th\u003e\n\u003ctd\u003eCheck winding identification, excitation and polarity before assessing the resolver itself. Record results at multiple positions using the applicable fixture; keep motor alignment assessment separate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and memory\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming mechanical datum, direction and motor phase convention before disturbing the sensor. No numerical commutation angle or universal memory image is specified here. A motor-specific alignment requires the exact motor data, supported equipment setup and applicable OEM procedure. Preserve any recoverable offset, identity and parameter data before changes; establish hardware and data compatibility before a specialist transfer or write. Resolver electrical zero and the machine datum are different references. A replacement that reads angle correctly still needs the correct phase relationship to the motor.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eParker HDY\/HJ resolver branch. HDY HIPERFACE uses a documented 17-contact connection; this row is resolver-only.\u003c\/p\u003e\n\u003cp\u003eA matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMitchell test cable index by manufacturer\u003c\/a\u003e — PDF page 11, exact TI-5907 row\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26578514023963-Generic-Resolvers\" target=\"_blank\" rel=\"noopener\"\u003eGeneric Resolvers\u003c\/a\u003e — J12 excitation, angle and vector checks. OEM excitation and fitted wiring still required.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.parkermotion.com\/manuals\/Hauser\/HDY_HJ.pdf\" target=\"_blank\" rel=\"noopener\"\u003eParker HJ \/ HDY synchronous servo motors — 192-060011 N5, December 2000\u003c\/a\u003e — Legacy application reference: pages 6\/15 cover SCS60\/SCM60 retention; pages 25 and 28 show resolver and SinCos wiring; pages 29–30 show order options and cable codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePrimary family\/application PDF linked; exact fitted order, fixture, internal loom and alignment evidence remain to confirm.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should accompany a HDY \/ HJ resolver enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear photographs of the motor and feedback labels, every suffix\/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed Mitchell lead be used as a replacement machine cable?\u003c\/summary\u003e\u003cp\u003eThe lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a successful feedback bench test prove that the motor can be run? \u003c\/summary\u003e\u003cp\u003eCable-index evidence only for this connection. Exact motor-run profile, power\/brake wiring, motor data and alignment remain unverified. A complete run assessment also checks motor power, brake, protection and mechanical conditions.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhen does a site visit or send-in evaluation make sense?\u003c\/summary\u003e\u003cp\u003eA site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51135053103269,"sku":"TCG418","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/parker-hdy-hj-resolver-service-guide.jpg?v=1794310262","url":"https:\/\/www.sparefaber.com\/de\/products\/parker-hdy-hj-resolver-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}