{"product_id":"posital-ucd-e2a2b-1413-h150-pam-powerlink","title":"POSITAL UCD-E2A2B-1413-H150-PAM POWERLINK Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for UCD-E2A2B installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"POSITAL UCD-E2A2B-1413-H150-PAM POWERLINK Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse the approved POWERLINK controller or diagnostic setup with a compatible device description. Verify link, node state, cyclic position and saved settings. Confirm exact Mitchell capability before choosing a feedback tester. Network bench diagnosis and a powered machine run are separate setups.\u003c\/p\u003e\n\u003ch2\u003ePOSITAL UCD-E2A2B-1413-H150-PAM POWERLINK Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eUCD-E2A2B-1413-H150-PAM\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUCD-E2A2B-1413-H150-PAM · 1434160\u003c\/th\u003e\n\u003ctd\u003e58 mm blind-hollow design, 15 mm shaft, 30 mm bore depth in exact record.\u003c\/td\u003e\n\u003ctd\u003ePOWERLINK V2, 13-bit singleturn plus 14-bit multiturn.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUCD-E2A2B-1413-HFS0-PAM · 1888054\u003c\/th\u003e\n\u003ctd\u003ePOSITAL lists this as the replacement. Both records name a 15 mm blind hollow shaft. Compare current mating drawings.\u003c\/td\u003e\n\u003ctd\u003eSame documented protocol and resolution classes. Verify setup and controller device identity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003ePOSITAL labels item 1434160 as Lab Sample and lists UCD-E2A2B-1413-HFS0-PAM item 1888054 as its replacement. This is a documented part transition. Confirm procurement and support for the installed suffix.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for UCD-E2A2B-1413-H150-PAM\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for UCD-E2A2B-1413-H150-PAM\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition\u003c\/th\u003e\n\u003ctd\u003e8,192 positions per turn and 16,384 turns. POSITAL describes a self-powered magnetic turn counter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNetwork\u003c\/th\u003e\n\u003ctd\u003eEthernet POWERLINK V2, DS-406 profile. Product record specifies cycle time at least 400 µs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e10–30 V DC, up to 230 mA at 10 V or 100 mA at 24 V per exact record.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical\u003c\/th\u003e\n\u003ctd\u003e15 mm blind bore, 30 mm depth, 58 mm flange size. Actual shaft engagement comes from the mating drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePorts\u003c\/th\u003e\n\u003ctd\u003eTwo female four-contact D-coded Ethernet M12 ports and one male four-contact A-coded supply M12.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/dms.posital.com\/pdf\/manual-ixarc-xcx-e2.pdf#page=9\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eMatch the shaft to the 15 mm blind bore and check insertion so the shaft does not bottom. Use the documented clamping ring and torque support. Inspect witness marks, shaft movement and mounting plate strain after isolation. Compare shaft engagement and anti-rotation hardware before ordering the HFS0 replacement.\u003c\/p\u003e\n\u003cp\u003eUse POSITAL's exact-ID drawings for fit and connector clearance. Record which ports are used and where each cable goes.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe encoder reports absolute position on a POWERLINK network under the controller's cyclic schedule. An Ethernet link light shows the physical path is present. Position exchange also depends on the node configuration, network state, controller mapping and configured process values. Capture the controller's state and error history before changing parameters.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThe UME-xCx-E2 manual sections 4.1 and 4.2 show views of the encoder connectors. Keep the A-coded power port and the D-coded Ethernet ports separate.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"POSITAL POWERLINK encoder M12 contacts\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003ePOSITAL POWERLINK encoder M12 contacts\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePort\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented connections\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA-coded supply, male\u003c\/th\u003e\n\u003ctd\u003e1 +10–30 V DC, 3 supply GND. Contacts 2 and 4 reserved.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eD-coded Ethernet, female, either port\u003c\/th\u003e\n\u003ctd\u003e1 Tx+, 2 Rx+, 3 Tx−, 4 Rx−.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe manual distinguishes straight and crossed cable maps. Confirm the controller-side pinout and approved topology.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003ePOSITAL lists \u003cstrong\u003eCBL-M12S-M04D-020EH-046Y-R45F-M080\u003c\/strong\u003e, a 2 m D-coded M12-to-RJ45 cable, under 1434160 accessories. The same page lists field connector \u003cstrong\u003eCTR-M12S-M04D-NPSC\u003c\/strong\u003e (34050402). Verify pair map and cable duty against the actual equipment. Order a separate power cordset with the documented A-coded mating connector.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNeither Ethernet port links\u003c\/th\u003e\n\u003ctd\u003eVerify the A-coded supply first. Then trace the correct shielded D-coded cable and port.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEthernet links, controller lacks position\u003c\/th\u003e\n\u003ctd\u003eCheck POWERLINK node address, device description, network state and PDO mapping.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition changes by a fixed offset\u003c\/th\u003e\n\u003ctd\u003eCompare saved preset and direction. Inspect the shaft clamp for slip after isolation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault follows replacement\u003c\/th\u003e\n\u003ctd\u003eCompare identity, firmware, device description and resolution. Verify the HFS0 settings and dimensions with the OEM.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThis page applies to POSITAL item 1434160. The HFS0 is the manufacturer-listed replacement, subject to fit and commissioning checks. Refer to the separate \u003ca href=\"\/de\/products\/twk-trk58-kpa65536r4096s3mk01-fsoe\"\u003eTWK FSoE guide\u003c\/a\u003e when the installed device uses EtherCAT. Network connectors can look similar while protocol and configuration differ.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSave the original node setup, scaling, direction, preset and physical reference if readable. Re-establish the machine datum after installing the shaft and validate the permitted travel and turn count. Treat any motor-specific electrical offset as an OEM setting.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/dms.posital.com\/pdf\/manual-ixarc-xcx-e2.pdf#page=9\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.posital.com\/en\/products\/absolute-encoders\/UCD-E2A2B-1413-H150-PAM\/1434160\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.posital.com\/en\/products\/absolute-encoders\/UCD-E2A2B-1413-HFS0-PAM\/1888054\"\u003ePOSITAL-listed replacement 1888054\u003c\/a\u003e. Compare the HFS0 exact record and drawing.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/dms.posital.com\/pdf\/manual-ixarc-xcx-e2.pdf#page=10\"\u003ePOWERLINK cable maps\u003c\/a\u003e. The manual separates straight and crossed cable wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51119407628453,"sku":"TCG102","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/posital-ucd-e2a2b-1413-h150-pam-powerlink-service-guide.jpg?v=1794148290","url":"https:\/\/www.sparefaber.com\/de\/products\/posital-ucd-e2a2b-1413-h150-pam-powerlink","provider":"SpareFaber","version":"1.0","type":"link"}