{"product_id":"renishaw-atom-dx-a4a0z15a10f","title":"Renishaw ATOM DX A4A0Z15A10F Optical Linear Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for ATOM DX installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Renishaw ATOM DX A4A0Z15A10F Optical Linear Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eRenishaw documents ADTi-100 and ADT View for supported installation and fault diagnosis. A differential receiver can also check quadrature and Z with the correct supply and termination. Check exact Mitchell profile and adapter compatibility before using that equipment.\u003c\/p\u003e\n\u003ch2\u003eRenishaw ATOM DX A4A0Z15A10F Optical Linear Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eA4A0Z15A10F\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA4A0Z15A10F\u003c\/th\u003e\n\u003ctd\u003eCabled 40 µm linear or partial-arc readhead, 1.5 m cable, 9-way D-type.\u003c\/td\u003e\n\u003ctd\u003e0.5 µm resolution, 10 MHz clocked output option, three-state alarm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA4A0X15A10F\u003c\/th\u003e\n\u003ctd\u003eSimilar cabled 40 µm format. Confirm compatible scale and mounting drawing.\u003c\/td\u003e\n\u003ctd\u003e1 µm resolution. Update the controller scale factor for this distinct order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA4L0Y00Z10F\u003c\/th\u003e\n\u003ctd\u003eSeparate top-exit configuration. Confirm its applicable cable and scale.\u003c\/td\u003e\n\u003ctd\u003e0.1 µm resolution. Its connector and output setup differ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eRenishaw's product store lists A4A0Z15A10F and links technical documentation. Confirm current stock, production and scale availability for the exact order.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for A4A0Z15A10F\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for A4A0Z15A10F\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible scale\u003c\/th\u003e\n\u003ctd\u003eRTLF40 or RKLF40 for the reference A4A0Z15A10F product, 40 µm pitch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003eDigital RS-422A A\/B plus reference Z. Interpolated resolution 0.5 µm, 10 MHz clocked option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003e1.5 m attached cable with 9-way D-type A termination, 5 V supply per data sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlarm\u003c\/th\u003e\n\u003ctd\u003eThree-state output alarm for this order. The A connector has no separate single-ended alarm pin.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit\u003c\/th\u003e\n\u003ctd\u003eUse the ATOM DX and RTLF installation guide for ride height, pitch, roll, yaw and reference setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download?data=120693\u0026amp;lang=en\u0026amp;userLanguage=en\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eMatch the head to the scale before fitting. Use the correct scale guide and Renishaw setup gauge to establish ride height, yaw, pitch and roll. Sweep the usable travel and check setup indication or diagnostic signal strength. A head can look aligned at one point while the rail flexes enough to lose signal elsewhere.\u003c\/p\u003e\n\u003cp\u003eClean and handle the scale according to the manufacturer instructions. Protect the head's cable from strain and keep the reference mark arrangement visible for setup.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe readhead reads the optical grating, interpolates inside the head and sends differential A and B position pulses plus Z reference. The controller converts edge counts to travel. The 10 MHz option describes the chosen output timing. Apply the data-sheet speed table and the receiver limits together when checking a dropout at speed.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the 9-way D-type column marked A in data sheet L-9517-9736-05-A, page 18. Verify mating face numbering on the connector. Other ATOM DX D-type and JST terminations have different pinouts.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"A4A0Z15A10F D-type A termination\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eA4A0Z15A10F D-type A termination\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePin or pair\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e5 V \/ 0 V\u003c\/th\u003e\n\u003ctd\u003e5 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA+ \/ A−\u003c\/th\u003e\n\u003ctd\u003e2 \/ 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eB+ \/ B−\u003c\/th\u003e\n\u003ctd\u003e4 \/ 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZ+ \/ Z−\u003c\/th\u003e\n\u003ctd\u003e3 \/ 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRemote CAL\u003c\/th\u003e\n\u003ctd\u003e9, use the documented method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShield\u003c\/th\u003e\n\u003ctd\u003eConnector case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eStart with the factory 1.5 m cable and A termination. Use the Renishaw-approved extension for the chosen connector and receiver arrangement. The sheet specifies a separate maximum cable length to ADTi-100. Obtain an exact extension order from Renishaw with both end drawings and total length.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSetup indicator varies across travel\u003c\/th\u003e\n\u003ctd\u003eInspect scale flatness and head ride height and attitude along the full length.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGood setup but incorrect travel\u003c\/th\u003e\n\u003ctd\u003eCompare A\/B wiring and controller resolution against the 0.5 µm build.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference missing\u003c\/th\u003e\n\u003ctd\u003eVerify scale reference type, calibration and the Z pair at the receiver.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSignal lost only at high speed\u003c\/th\u003e\n\u003ctd\u003eCheck receiver frequency, selected output clock, termination and cable loading.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThis is an optical linear or partial-arc incremental system for the specified scale. Confirm the machine's scale type and control input, particularly if a physically similar readhead uses a different grating pitch or resolution.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSet and verify the readhead geometry, then use the Renishaw calibration and reference-mark procedure for the actual scale. Confirm count direction and machine home. The model's alignment task is optical geometry and datum rather than a motor electrical angle.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download?data=120693\u0026amp;lang=en\u0026amp;userLanguage=en\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/store.renishaw.com\/en-AE\/product\/A4A0Z15A10F\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/installation-guide-atom-dx-and-rtlf-linear-encoder-system--145405?userLanguage=en\"\u003eRenishaw ATOM DX with RTLF installation guide\u003c\/a\u003e. Follow the matching scale and head configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download?data=120693\u0026amp;lang=en\u0026amp;userLanguage=en#page=18\"\u003eRenishaw D-type and JST pin assignments\u003c\/a\u003e. Use the A column for this exact cabled head.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51119407792293,"sku":"TCG106","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/renishaw-atom-dx-a4a0z15a10f-service-guide.jpg?v=1794148299","url":"https:\/\/www.sparefaber.com\/de\/products\/renishaw-atom-dx-a4a0z15a10f","provider":"SpareFaber","version":"1.0","type":"link"}