{"product_id":"rexroth-indramat-2ad-c-d-incremental-spindle-feedback","title":"Bosch Rexroth Indramat 2AD C \/ D Incremental Spindle Feedback | Technical Guide | Service Visit for Feedback Diagnosis and Installation","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eUse the complete 2AD type code to identify the C or D feedback option, then count the feedback connector contacts. Mitchell provides separate incremental test drawings for the 9-contact and 12-contact M23 assemblies.\u003c\/p\u003e\n\u003cp\u003eSpareFaber can diagnose the documented feedback and cable connection on site or on the bench. Send the full spindle order and connector photo so we can scope an encoder installation or send-in check.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Bosch Rexroth Indramat 2AD C \/ D Incremental Spindle Feedback technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Read the option and plug first, then check the documented C\/D incremental signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Encoder bench diagnosis only in the documented Mitchell scope for these asynchronous spindles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e TI-5613 for the documented 9-contact M23. TI-5022 for the documented 12-contact M23.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eBosch Rexroth Indramat 2AD C \/ D Incremental Spindle Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2AD C or D\u003c\/th\u003e\n\u003ctd\u003eIncremental spindle branch in Mitchell’s 2AD options table. Confirm the type-code position and complete motor order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e9-contact M23\u003c\/th\u003e\n\u003ctd\u003eUse Mitchell Image 3 and the TI-5613 reference for this plug.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e12-contact M23\u003c\/th\u003e\n\u003ctd\u003eUse Mitchell Image 4 and TI-5022 for this plug.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2AD 6, 7, 8 or 9\u003c\/th\u003e\n\u003ctd\u003eThese option codes have a different BRI_I2C test path.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMachine class\u003c\/th\u003e\n\u003ctd\u003eAir-cooled asynchronous 2AD spindle motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback type\u003c\/th\u003e\n\u003ctd\u003eIncremental channels with reference on the illustrated C\/D connection. Identify the exact fitted encoder to establish line count and signal level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBench selection\u003c\/th\u003e\n\u003ctd\u003eAthena Generic Incremental with the cable matched to the motor plug.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe drive derives relative spindle movement and direction from the two incremental channels. The reference channel is a separate part of the diagnosis. A clean A\/B count with a missing reference can still cause an orientation fault.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the 2AD frame and rear encoder assembly drawing. Record the locating seat, actual ROD or fitted encoder label and drive connection before disturbing the assembly. Check for bearing play and coupling damage where the OEM procedure permits access.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eFollow Mitchell Images 3 and 4 for the exact 9- or 12-contact view. Confirm the encoder output level on its own label or drawing before applying a supply. Keep the spindle power, fan and thermal circuits separate.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eIdentify the internal feedback lead from the spindle assembly and the drive cable from the actual drive and plug. TI-5613 and TI-5022 are test fixtures. They identify the supported bench connections.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eUse only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpindle turns but orientation fails\u003c\/th\u003e\n\u003ctd\u003eVerify reference activity and the machine’s orientation setting independently of the A\/B tracks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo count on the test fixture\u003c\/th\u003e\n\u003ctd\u003eCheck the actual contact count, connector view and both signal paths against Mitchell’s drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCounts change when moving the loom\u003c\/th\u003e\n\u003ctd\u003eInspect strain at the rear cover and run isolated cable checks before condemning the encoder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eMitchell describes no feedback commutation alignment requirement for the asynchronous 2AD. After mechanical work, confirm direction, reference integrity and any machine spindle orientation procedure on the installed drive.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eIndramat 2AD asynchronous spindle, C or D option\u003c\/p\u003e\n\u003cp\u003eDistinguish the C\/D connectors and check feedback on the spindle without applying the Option 6 I²C setup.\u003c\/p\u003e\n\u003ch3\u003eRelated SpareFaber guides\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/de\/products\/rexroth-indramat-2ad104-option-6-feedback\"\u003eBosch Rexroth Indramat 2AD104C-B05OB1-CS06-A2N1 Option 6 Spindle Feedback\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/25296476690587-Indramat-2AD-Asynchronous-Motors\"\u003eIndramat 2AD Asynchronous Motors\u003c\/a\u003e. Feedback Connections, C and D, Images 3 and 4\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26564715015195-Generic-Incremental-Quadrature-Pulse-Encoders\"\u003eMitchell Generic Incremental Quadrature Pulse Encoders\u003c\/a\u003e. Supplementary reference for the stated model or setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/rgbelektronika.pl\/wp-content\/uploads\/2024\/06\/Indramat_2AD-Project-Planning-Manual_Part1.pdf\"\u003eIndramat 2AD project planning manual\u003c\/a\u003e. OEM-authored legacy frame, type code and installation reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bobcat.mitchell-electronics.com\/parts\/116\"\u003eTI-5613 fixture\u003c\/a\u003e. Nine-contact M23 bench fixture.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bobcat.mitchell-electronics.com\/parts\/225\"\u003eTI-5022 fixture\u003c\/a\u003e. Twelve-contact M23 bench fixture.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51133536534693,"sku":"TCG288","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/rexroth-indramat-2ad-c-d-incremental-spindle-feedback-service-guide.jpg?v=1794290587","url":"https:\/\/www.sparefaber.com\/de\/products\/rexroth-indramat-2ad-c-d-incremental-spindle-feedback","provider":"SpareFaber","version":"1.0","type":"link"}