{"product_id":"rexroth-indramat-2ad104-option-6-feedback","title":"Bosch Rexroth Indramat 2AD104C-B05OB1-CS06-A2N1 Option 6 Spindle Feedback | Technical Guide | Service Visit for Installation \u0026 Feedback Diagnosis","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for 2AD104 spindle feedback diagnosis and send-in evaluation for compatible feedback assemblies. The feedback option and spindle drive determine the service scope.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Bosch Rexroth Indramat 2AD104C-B05OB1-CS06-A2N1 Option 6 Spindle Feedback technical guide\"\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Mitchell documents BRI_I2C in Athena and a spindle feedback identifier in memory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Mitchell excludes the 2AD asynchronous spindle motors from TI-3000JX run testing.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eBosch Rexroth Indramat 2AD104C-B05OB1-CS06-A2N1 Option 6 Spindle Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eIdentification and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2AD104C-B05OB1-CS06-A2N1\u003c\/th\u003e\n\u003ctd\u003eMotor-order example. The feedback digit 6 identifies digital servo feedback in the 2AD104 order key.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOption 7\u003c\/th\u003e\n\u003ctd\u003eRelated 2AD feedback with integrated multiturn absolute function. Keep its assembly and documentation separate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOptions C and D\u003c\/th\u003e\n\u003ctd\u003eDistinct incremental feedback branches in Mitchell’s article.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm current orderability and any successor for the exact ID with the manufacturer or motor OEM. The dated documentation identifies the configuration.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data for 2AD104C-B05OB1-CS06-A2N1\" tabindex=\"0\"\u003e\u003ctable\u003e\n\u003ccaption\u003eReference data for 2AD104C-B05OB1-CS06-A2N1\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor type\u003c\/th\u003e\n\u003ctd\u003eAsynchronous, air-cooled spindle motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback\u003c\/th\u003e\n\u003ctd\u003eOption 6 digital servo feedback. The actual feedback assembly part number remains open.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBench profile\u003c\/th\u003e\n\u003ctd\u003eBRI_I2C selection in Athena for the documented 2AD options 6–9.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMemory scope\u003c\/th\u003e\n\u003ctd\u003eMitchell describes a spindle feedback identifier rather than a full servo motor parameter file.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the 2AD104 motor drawing for feedback housing clearance and the approved removal procedure. Inspect the bulkhead and connector retention before opening the spindle feedback assembly.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe digital feedback option provides position information to the spindle drive. Treat an identifier read and a repeatable movement reading as separate checks. A readable identifier does not prove the entire feedback path is healthy.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eMitchell supplies a feedback connection figure for the options 6–9 arrangement. Use it with the exact motor drawing and identify connector orientation before comparing supply, signal and shield conductors. The C\/D option pin maps belong to other builds.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eUse TI-5021 and TI-5104 for the documented bench connection. The installed spindle loom and the Mitchell test lead are separate items. Check the fitted motor connector and loom label.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore inspection.\u003c\/strong\u003e Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIdentifier reads but the position is unstable\u003c\/th\u003e\n\u003ctd\u003eCheck mechanical seating, signal integrity and the feedback board connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo feedback detected after a connector repair\u003c\/th\u003e\n\u003ctd\u003eConfirm option 6 and compare the fitted bulkhead with the correct options 6–9 drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpindle alarm persists with verified feedback\u003c\/th\u003e\n\u003ctd\u003eReview drive alarm history and the installed motor-to-drive harness before replacing the encoder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003e2AD104C-B05OB1-CS06-A2N1 Check the exact ID, drive and connector before applying an installation or test procedure.\u003c\/p\u003e\n\u003cp\u003eDistinguish a cable or feedback-board issue from a drive fault. Obtain the fitted feedback assembly ID from the motor.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eMitchell states that these asynchronous motors do not require feedback commutation alignment. Retain any machine spindle-orientation or reference settings and verify them with the spindle drive procedure after reassembly.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/25296476690587-Indramat-2AD-Asynchronous-Motors\"\u003eIndramat 2AD support\u003c\/a\u003e. Overview and Feedback Connections. Options 6–9.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/nuovaelva.it\/docs\/Bosch%20Rexroth\/Tecnologie%20e%20prodotti%20per%20il%20controllo%20del%20movimento\/26057603.pdf\"\u003eRexroth 2AD project planning manual R911260576\u003c\/a\u003e. The 2AD104 type code separates option 6 from variants with integrated absolute feedback.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51127089725605,"sku":"TCG169","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/rexroth-indramat-2ad104-option-6-feedback-service-guide.jpg?v=1794236162","url":"https:\/\/www.sparefaber.com\/de\/products\/rexroth-indramat-2ad104-option-6-feedback","provider":"SpareFaber","version":"1.0","type":"link"}