{"product_id":"sew-eg7s-sincos-incremental-plug-in-shaft-encoder","title":"SEW-EURODRIVE EG7S 1 Vpp Plug-In Shaft Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eIdentify EG7S on the motor option list and read the fitted shaft and terminal-box drawing. This SEW plug-in shaft encoder provides analogue incremental tracks, including a separate once-per-turn reference.\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE on-site fault diagnosis, installation and alignment checks for the documented feedback. Send the fitted labels and alarm details to arrange a visit or a send-in evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"SEW-EURODRIVE EG7S 1 Vpp Plug-In Shaft Encoder technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Check sine and cosine quality, reference path where fitted and mechanical repeatability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Specific TI-3000JX scope remains open for the fitted DR motor and drive.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e Use the fitted EG7S and drive connector drawing to select the 1 Vpp test path.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eSEW-EURODRIVE EG7S 1 Vpp Plug-In Shaft Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEG7S\u003c\/th\u003e\n\u003ctd\u003eSEW incremental plug-in shaft option in the linked DR catalogue and technical table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eES7S\u003c\/th\u003e\n\u003ctd\u003eRelated spread-shaft construction. Compare the motor end and attachment drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEH7S\u003c\/th\u003e\n\u003ctd\u003eThe adjacent table gives a separate connection, supply and mounting branch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAG7Y\u003c\/th\u003e\n\u003ctd\u003eDifferent plug-in shaft feedback with absolute SSI in addition to analogue tracks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eSEW documents plug-in shaft predecessors and cone-shaft successors. Confirm the compatible replacement and any required mechanical or cabling changes for the full motor order.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEG7S supply\u003c\/th\u003e\n\u003ctd\u003e7–30 V DC in the linked SEW technical table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA\/B and C tracks\u003c\/th\u003e\n\u003ctd\u003e1,024 A\/B periods per revolution and one C reference. SEW separately states 4,096 increments.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSignal amplitude\u003c\/th\u003e\n\u003ctd\u003e1 V peak-to-peak. Compare frequency and termination against the exact documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003eTerminal box at the EG7S encoder in the technical data. EH7S has a separate M23 connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe drive interpolates the two analogue tracks for relative motion and direction. The reference track serves a separate indexing function. Record both the actual sine periods and the controller’s decoded count convention.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eCheck the plug-in shaft seat and torque bracket against the fitted DR assembly. Record the encoder’s seating, the bracket orientation and the rear-cover clearance. Compare the shaft-centered and cone-shaft drawings before an upgrade.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eUse the terminal-box diagram for the fitted EG7S. Trace supply, return, both analogue pairs and the reference pair on the exact drawing. Avoid applying the EH7S M23 pin map to the EG7S terminal box.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eTrace the encoder terminal block and the cable to the drive. Select a suitable screened loom based on the DR order and drive input, and document the fixed or flexing cable route. A Mitchell adaptor, if matched, serves the bench path.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eUse only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGood speed reading with an orientation alarm\u003c\/th\u003e\n\u003ctd\u003eCheck the reference track and its receiver independently of the two movement channels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition noise varies with speed\u003c\/th\u003e\n\u003ctd\u003eCheck analogue amplitude, shielding, supply and termination using the approved test arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault began after changing the rear assembly\u003c\/th\u003e\n\u003ctd\u003eCheck plug-in shaft seating, bracket freedom and cable strain.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eKeep the bracket and any machine reference marks intact during service. Confirm count direction and reference detection after installation using the actual SEW drive and axis procedure.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eSEW DR160–225 on the documented EG7S branch\u003c\/p\u003e\n\u003cp\u003eIdentify the plug-in shaft and analogue output, and distinguish EG7S from the digital EG7C branch.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/27282690417947-SEW-Servo-Motors\"\u003eSEW Servo Motors\u003c\/a\u003e. Mitchell-linked Incremental encoders for DR motors table, EG7S row\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.sew-eurodrive.com\/sew_in\/media\/sew_eurodrive\/sew_ind_pdf\/brochures\/catalog\/2a_25957074_ac_motors_dr71_-_315_drn63_-_315_dr256_-_8.pdf\"\u003eSEW AC motors catalogue, EG7S and related plug-in options\u003c\/a\u003e. Manufacturer reference for the indicated motor or feedback option. Check the fitted revision.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/download.sew-eurodrive.com\/download\/html\/31974465\/en-EN\/39126691723.html\"\u003eSEW EG7S \/ EH7S technical data\u003c\/a\u003e. Separate supply, signal and connection entries for EG7S and EH7S.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51133566025893,"sku":"TCG301","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/sew-eg7s-sincos-incremental-plug-in-shaft-encoder-service-guide.jpg?v=1794291240","url":"https:\/\/www.sparefaber.com\/de\/products\/sew-eg7s-sincos-incremental-plug-in-shaft-encoder","provider":"SpareFaber","version":"1.0","type":"link"}