{"product_id":"sew-ei7c-dr-motor-htl-incremental-encoder","title":"SEW-EURODRIVE EI7C Built-In HTL Incremental Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eThe EI7C is the 24-period member of SEW’s built-in HTL encoder group. Check the exact generation and motor option before picking a terminal drawing or cable.\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE on-site fault diagnosis, installation and alignment checks for the documented feedback. Send the fitted labels and alarm details to arrange a visit or a send-in evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"SEW-EURODRIVE EI7C Built-In HTL Incremental Encoder technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Trace HTL output and supply using the fitted EI7C variant drawing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Documented TI-3000JX setup for this DR induction motor branch remains open.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e Choose from the exact motor terminal or cable drawing. No EI7C-specific Mitchell lead listed.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eSEW-EURODRIVE EI7C Built-In HTL Incremental Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEI7C\u003c\/th\u003e\n\u003ctd\u003eThe SEW DR table identifies 24 A\/B periods per mechanical turn on the documented standard branch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEI76 \/ EI72 \/ EI71\u003c\/th\u003e\n\u003ctd\u003eThe companion codes designate 6, 2 and 1 period per turn respectively in the same SEW table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEI7C B and EI7C FS\u003c\/th\u003e\n\u003ctd\u003eThe exact revision and any safety designation change the applicable drawing and service procedure. Record all motor and encoder label fields.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003eA\/B incremental HTL on the documented DR built-in encoder group.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e24 periods per revolution for EI7C. Receiver edge counting can show a different count.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003eThe documented DR71–DR132 catalogue grouping lists 9–30 V DC. Confirm the installed revision and safety variant drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eBuilt-in at the motor non-drive end, associated with the fan and endshield arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe controller derives movement and direction from the relative sequence of the A and B channels. Speed feedback can appear plausible with one channel missing while direction or low-speed detection becomes unreliable.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the SEW EI7 installation section for the specific DR frame and generation. The assembly is at the fan end. Verify the sensing components, their seating and cable routing before disturbing the fan or endshield.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eMatch the SEW terminal-box or M12 drawing to the fitted connector and revision. Identify supply and return, A and B, and complements where fitted. The catalogue distinguishes connector options and configuration terminals.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eRecord the motor order and encoder connection option before selecting the terminal-box wiring kit or field cable. Keep encoder leads clear of the motor power route as shown in the OEM instructions.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eUse only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWrong speed ratio\u003c\/th\u003e\n\u003ctd\u003eCompare the EI7C marking and controller edge-count setting with the 24-period table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOnly one output toggles\u003c\/th\u003e\n\u003ctd\u003eCheck A and B individually at the verified low-voltage connector and inspect the terminal box.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSignal disappears after fan-end service\u003c\/th\u003e\n\u003ctd\u003eInspect seating, wheel alignment, connector routing and the fitting sequence in the SEW manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eThis guide covers incremental motor feedback. Retain the sensor and wheel arrangement and validate direction and signal count after service. If the machine uses a reference or safety function, follow its specific recommissioning process.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eSEW DR71–DR132, applicable EI7C order\u003c\/p\u003e\n\u003cp\u003eTell EI7C from its lower-resolution siblings and locate the built-in signal connection.\u003c\/p\u003e\n\u003ch3\u003eRelated SpareFaber guides\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/de\/products\/sew-as7w-13630776-encoder\"\u003eSEW-EURODRIVE AS7W 13630776 Sin\/Cos and SEW RS-485 Encoder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/de\/products\/sew-as7y-dr71-dr132-ssi-multiturn-encoder\"\u003eSEW-EURODRIVE AS7Y DR71–DR132 SSI Multiturn Encoder\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/de\/products\/siemens-simotics-s-1fl6-type-a-ttl-feedback\"\u003eSiemens SIMOTICS S-1FL6 Type A TTL Incremental Servo Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/27282690417947-SEW-Servo-Motors\"\u003eSEW Servo Motors\u003c\/a\u003e. Attached Incremental encoders for DR motors table, EI7C\/EI76\/EI72\/EI71\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26564715015195-Generic-Incremental-Quadrature-Pulse-Encoders\"\u003eGeneric Incremental Quadrature Pulse Encoders\u003c\/a\u003e. Supplementary reference for the stated model or setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.sew-eurodrive.com\/sew_in\/media\/sew_eurodrive\/sew_ind_pdf\/brochures\/catalog\/2a_25957074_ac_motors_dr71_-_315_drn63_-_315_dr256_-_8.pdf\"\u003eSEW AC motors catalogue\u003c\/a\u003e. Built-in encoder table and generation-specific wiring and connector diagrams.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.sew-eurodrive.com\/sew_in\/media\/sew_eurodrive\/sew_ind_pdf\/manuals\/2b_26861313_correction_sheet_ac_motors_dr71_-_315_drn63.pdf\"\u003eSEW EI7 installation and wiring revision\u003c\/a\u003e. Frame and motor-revision scope for installation at the fan end.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51131194310821,"sku":"TCG264","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/sew-ei7c-dr-motor-htl-incremental-encoder-service-guide.jpg?v=1794277374","url":"https:\/\/www.sparefaber.com\/de\/products\/sew-ei7c-dr-motor-htl-incremental-encoder","provider":"SpareFaber","version":"1.0","type":"link"}