{"product_id":"sew-eurodrive-as3h-as4h-feedback-technical-guide","title":"SEW-EURODRIVE AS3H \/ AS4H | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSEW-EURODRIVE AS3H \/ AS4H — Multiturn HIPERFACE + 1 Vpp. Use this guide to identify the fitted feedback, separate connection faults from sensor faults and prepare a supported evaluation. SpareFaber can assess an appropriate UAE site visit, installation\/alignment work or send-in bench evaluation after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentify the fitted part\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eSend an enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted part\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"id-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide scope\u003c\/th\u003e\n\u003ctd\u003eSEW-EURODRIVE AS3H \/ AS4H — Standalone device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback identity\u003c\/th\u003e\n\u003ctd\u003eAS3H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMain designation\u003c\/th\u003e\n\u003ctd\u003eAS3H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDocumented motor example\u003c\/th\u003e\n\u003ctd\u003eNo complete fitted motor order has been verified; retain every nameplate suffix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eMultiturn HIPERFACE + 1 Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting connection\u003c\/th\u003e\n\u003ctd\u003eTI-5650 with TI-5104 only on the matching 12-contact M23 HIPERFACE motor connection; terminal-box or direct-encoder connections need their own verified drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration distinction\u003c\/th\u003e\n\u003ctd\u003eGroup AS3H\/AS4H together; distinct mounting\/application from AV1H and CFM AS1H.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: connection before conclusion\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX bench scope\u003c\/th\u003e\n\u003ctd\u003eTI-5000JX feedback evaluation is conditional on the exact fitted option and verified fixture. Legacy DT\/CT spread-shaft option; check 4,096-period analogue tracks and motor fit. Evaluate serial identity\/status and analogue tracks separately; motor-memory work requires the corresponding SEW support.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead \/ fixture\u003c\/th\u003e\n\u003ctd\u003eTI-5650 with TI-5104 only on the matching 12-contact M23 HIPERFACE motor connection; terminal-box or direct-encoder connections need their own verified drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfile \/ module\u003c\/th\u003e\n\u003ctd\u003eVerify exact supply, profile, connector and installed software. Named model evidence does not establish a complete fitted setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX motor-run scope\u003c\/th\u003e\n\u003ctd\u003eFeedback identification\/bench scope only. No TI-3000JX asynchronous motor-run approval is implied.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe documented test reference is SEW Servo Motors — Absolute encoder table: AS3H \/ AS4H. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eCurrent order availability and a verified successor for the exact fitted item remain to confirm. Technical documentation does not establish stock or a drop-in replacement. Match mechanical fit, interface, connector, memory and motor\/drive requirements before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface \/ feedback option\u003c\/th\u003e\n\u003ctd\u003eMultiturn HIPERFACE + 1 Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDocumented mechanical application\u003c\/th\u003e\n\u003ctd\u003eSpread shaft; DT71–DV132S \/ CT71–CV132S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDocumented electrical configuration\u003c\/th\u003e\n\u003ctd\u003eMultiturn HIPERFACE plus 1 Vpp; 4,096 analogue periods; 7–12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExact dimensions and fastening\u003c\/th\u003e\n\u003ctd\u003eUse the matching manufacturer outline, shaft drawing and revision. No universal shaft torque, air gap or fastener setting is assigned.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eClassic HIPERFACE combines serial identity\/position\/data with analogue sine\/cosine tracks. Test both paths independently. Singleturn and multiturn options have different revolution information; a correct within-turn reading does not establish multiturn operation. This guide does not extend to HIPERFACE DSL.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003eThe documented mounting is Spread shaft; DT71–DV132S \/ CT71–CV132S. Photograph the incoming reference, locating seat, shaft restraint, fasteners and cable exit before removal. Inspect accessible looseness, contamination, rubbing and bearing condition after isolation. Use the fitted outline for shaft engagement, retention and rear clearance. Preserve the incoming alignment and do not force an encoder or apply a torque from a similar-looking assembly.\u003c\/p\u003e\n\u003cp\u003eLegacy DT\/CT spread-shaft option; check 4,096-period analogue tracks and motor fit. Group AS3H\/AS4H together; distinct mounting\/application from AV1H and CFM AS1H. Spread shaft; DT71–DV132S \/ CT71–CV132S. Multiturn HIPERFACE plus 1 Vpp; 4,096 analogue periods; 7–12 V DC. Compare motor-frame ranges and electrical limits against the exact manual revision.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eTreat the sensor plug, internal motor loom, bulkhead, external machine cable and receiver as separate interfaces. Confirm contact numbering, keying, gender and the drawing view before tracing conductors. Identify supply\/return, signal pairs, temperature, shield and any separate brake wiring individually. Obtain the contact diagram for the actual connector before wiring an adapter.\u003c\/p\u003e\n\u003cp\u003eStarting connection for this guide: TI-5650 with TI-5104 only on the matching 12-contact M23 HIPERFACE motor connection; terminal-box or direct-encoder connections need their own verified drawing. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eAn exact internal OEM loom part number has not been established for the fitted unit. Record both loom ends and obtain the motor assembly drawing. External cable choice depends on receiver, length, shielding and fixed\/flexing installation. A Mitchell test lead identifies a bench connection, not an OEM machine-cable replacement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIsolation and measurement conditions\u003c\/summary\u003e\u003cp\u003eSecure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity\/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"fault-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIdentify the configuration first\u003c\/th\u003e\n\u003ctd\u003eLegacy DT\/CT spread-shaft option; check 4,096-period analogue tracks and motor fit. Group AS3H\/AS4H together; distinct mounting\/application from AV1H and CFM AS1H. Spread shaft; DT71–DV132S \/ CT71–CV132S. Multiturn HIPERFACE plus 1 Vpp; 4,096 analogue periods; 7–12 V DC. Compare motor-frame ranges and electrical limits against the exact manual revision.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent fault while the cable moves\u003c\/th\u003e\n\u003ctd\u003eAfter isolation and disconnection at both ends, inspect flex points, repairs, pin engagement and contamination. Compare continuity and unintended shorts against the exact drawing, allowing for intentional shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo signal or communication\u003c\/th\u003e\n\u003ctd\u003eVerify full order, interface, fixture and supply range. A qualified technician can compare source and load voltages with the approved breakout and OEM procedure; connector shape alone does not specify supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition reads but the drive still rejects feedback\u003c\/th\u003e\n\u003ctd\u003eCheck the independent signal paths, direction, motor identity and any supported reference\/turn status. Record the original alarm before changing settings. A data reset is not a substitute for identifying the fault.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial position is readable but motion feedback is unstable\u003c\/th\u003e\n\u003ctd\u003eMeasure sine\/cosine quality and their relationship with the matching fixture. Check supply, cable and shaft attachment before condemning the sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and memory\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming shaft datum, direction, motor phase convention and recoverable data before disturbing feedback. Use the exact OEM procedure and supported equipment for alignment or replacement. Matching electrical signals alone does not establish the correct motor pairing or machine origin. Mitchell’s SEW memory workflow can preserve the electronic nameplate on supported configurations. Do not assume the nameplate stores an individual commutation-offset value; follow the exact motor alignment procedure and original installation.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eAS3H \/ AS4H in the documented SEW motor table; exact fitted order to verify. Group AS3H\/AS4H together; distinct mounting\/application from AV1H and CFM AS1H.\u003c\/p\u003e\n\u003cp\u003eA matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/27282690417947-SEW-Servo-Motors\" target=\"_blank\" rel=\"noopener\"\u003eSEW Servo Motors\u003c\/a\u003e — Absolute encoder table: AS3H \/ AS4H\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/download.sew-eurodrive.com\/download\/pdf_u\/16742028.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSEW Drive Engineering – Encoder Systems, 16742028\u003c\/a\u003e — Use the stated family, option and document revision only\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.seweurodrive.com\/products\/motors\/accessories-and-options\/encoders\/encoders.html\" target=\"_blank\" rel=\"noopener\"\u003eSEW encoder options and predecessor\/successor families\u003c\/a\u003e — Current encoder system overview and EI71\/EI72\/EI76 periods\/decoded increments. Do not infer drop-in replacements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eObtain the complete fitted order, internal loom drawing, connector contact view and approved fixture before fitted-unit work. The linked family document does not establish interchangeability for every order.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should accompany a AS3H \/ AS4H enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear photographs of the motor and feedback labels, every suffix\/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed Mitchell lead be used as a replacement machine cable?\u003c\/summary\u003e\u003cp\u003eThe lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a successful feedback bench test prove that the motor can be run? \u003c\/summary\u003e\u003cp\u003eFeedback identification\/bench scope only. No TI-3000JX asynchronous motor-run approval is implied. A complete run assessment also checks motor power, brake, protection and mechanical conditions.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhen does a site visit or send-in evaluation make sense?\u003c\/summary\u003e\u003cp\u003eA site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51146750886053,"sku":"TCG624","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/sew-eurodrive-as3h-as4h-service-guide.jpg?v=1794343406","url":"https:\/\/www.sparefaber.com\/de\/products\/sew-eurodrive-as3h-as4h-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}