{"product_id":"sick-eds35-2kf0a020a-40-1112142","title":"SICK EDS35-2KF0A020A-40 1112142 HIPERFACE DSL Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for EDS35 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"SICK EDS35-2KF0A020A-40 1112142 HIPERFACE DSL Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eWe inspect the two-wire DSL link and motor cable, then check the taper fit and original application data before installation or commissioning. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell's TI-5743 is listed as a direct four-pin DSL lead. Verify the exact mating plug, compatible profile, firmware and module before connecting 1112142. An approved DSL diagnostic tool can separate link errors, temperature data and position problems. Verify TI-3000JX support separately for any complete motor run.\u003c\/p\u003e\n\u003ch2\u003eSICK EDS35-2KF0A020A-40 1112142 HIPERFACE DSL Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eEDS35-2KF0A020A-40\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEDS35-2KF0A020A-40 \/ 1112142\u003c\/th\u003e\n\u003ctd\u003ePackaged single-turn device with tapered shaft, stator coupling and mounting hardware as listed by SICK.\u003c\/td\u003e\n\u003ctd\u003e20-bit HIPERFACE DSL feedback. Separate four-pin communication and two-pin thermistor plugs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEDS35-2KF0A020A\u003c\/th\u003e\n\u003ctd\u003eFeedback unit listed within the 1112142 package.\u003c\/td\u003e\n\u003ctd\u003eUse the packaged ordering ID and unit label together when comparing the delivery contents.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEDM35-2KF0A020A \/ 1090711\u003c\/th\u003e\n\u003ctd\u003eRelated EDS\/EDM35-S family hardware. Compare mating drawing.\u003c\/td\u003e\n\u003ctd\u003eMultiturn configuration. Verify the motor's drive and approved safety configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eSICK publishes a datasheet for 1112142. Confirm production, orderability and any replacement for the exact package with SICK.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for EDS35-2KF0A020A-40\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for EDS35-2KF0A020A-40\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition\u003c\/th\u003e\n\u003ctd\u003e20-bit single-turn position for standard feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply and load\u003c\/th\u003e\n\u003ctd\u003e7–12 V at the encoder. Up to 150 mA with SICK’s specified DSL master circuit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback connection\u003c\/th\u003e\n\u003ctd\u003eFour-pin male device connector with two active DSL conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature input\u003c\/th\u003e\n\u003ctd\u003eSeparate two-pin thermistor connection on the device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor mounting\u003c\/th\u003e\n\u003ctd\u003eTapered shaft and stator coupling. Exact motor mating dimensions are in the 1112142 datasheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed and enclosure\u003c\/th\u003e\n\u003ctd\u003e≤12,000 min⁻¹. IP40 with cover closed and mating connector fitted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/5\/95\/295\/dataSheet_EDS35-2KF0A020A-40_1112142_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe taper centres the feedback rotor on the drive shaft. The central screw and stator coupling locate the assembly. Compare the motor's drive-shaft drawing, bearing references and mating face with SICK’s pages 4–5. Keep the encoder cover and both leads clear.\u003c\/p\u003e\n\u003cp\u003eUse the OEM's approved mounting sequence and fasteners. In a safety application, verify the exact encoder, fastener and mounting conditions against the motor's approved assembly procedure.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eHIPERFACE DSL carries supply and digital data over the same pair. A drive with a compatible DSL master separates the communication from the supply and reads the position and diagnostics. The thermistor is a separate input to the encoder. A normal average supply reading does not prove that the link is delivering valid frames.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThese are device cavity numbers from the SICK 1112142 sheet. Orient the latch and pin 1 by the SICK connection drawings on pages 5–6. The motor bulkhead or hybrid power cable uses the motor maker's pin map.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"EDS35 encoder-side connectors\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eEDS35 encoder-side connectors\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePlug\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePin\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4-pin DSL\u003c\/th\u003e\n\u003ctd\u003e1, 4\u003c\/td\u003e\n\u003ctd\u003eUnused\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4-pin DSL\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e+US \/ DSL+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4-pin DSL\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eGND \/ DSL−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2-pin thermistor\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eT+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2-pin thermistor\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eT−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe DSL mating housing specified by SICK is JST GHR-04V-S. The temperature plug is Harwin M80-8990205. Identify both before testing.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe SICK datasheet lists a 0.36 m twisted shielded flying-lead option DOL-0B02-G0M3AC2 (2108944) and a 0.2 m unshielded option DOL-0B02-G0M2XC2 (2079920). Compare the approved cable and screen routing for your motor. OEM hybrid cables and bulkhead connector pin maps vary.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply present, encoder absent\u003c\/th\u003e\n\u003ctd\u003eCheck both data\/supply conductors, shield routing, terminations and drive DSL compatibility. Read the drive link errors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eErrors only when the motor moves or the load changes\u003c\/th\u003e\n\u003ctd\u003eInspect the hybrid cable and connectors. Correlate link errors with cable flex or interference and verify the grounding arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature fault with steady position\u003c\/th\u003e\n\u003ctd\u003eInspect the separate thermistor plug and sensor circuit under the motor's approved procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault begins after an encoder replacement\u003c\/th\u003e\n\u003ctd\u003eConfirm unit code, supported drive firmware, saved motor data and OEM commissioning. Verify any safety checks before enabling service.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThe exact SICK order is documented by the manufacturer. Match the motor ID and the drive's DSL feedback profile, power cable and safety requirements before choosing a replacement. The motor OEM order and harness number still need confirmation.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003ePreserve the motor's original offset and device data if the OEM provides a verified read procedure. Record which values are stored in the encoder and which are in the drive. Restore only through the approved commissioning route for that same motor and encoder. Follow the equipment maker's required validation when the feedback participates in a safety function.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/5\/95\/295\/dataSheet_EDS35-2KF0A020A-40_1112142_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e. SICK order 1112142. Pages 4–6 show the taper, motor mating dimensions and separate supply\/communication and thermistor pin assignments.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/docs\/3\/93\/793\/product_information_eds_edm35_motor_feedback_system_rotary_hiperface_dsl%C2%AE_en_im0081793.pdf\"\u003eManufacturer reference\u003c\/a\u003e. SICK EDS\/EDM35 family product information. Apply the exact 1112142 datasheet for the covered package.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/docs\/7\/07\/607\/technical_information_hiperface_dsl_master_integration_manual_en_im0056607.pdf\"\u003eSICK HIPERFACE DSL master integration manual 8017595\u003c\/a\u003e. Supply and data coupling, master interface and diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\"\u003eMitchell manufacturer cable index\u003c\/a\u003e. Direct DSL lead and adapter family.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/5\/75\/875\/dataSheet_EDM35-2KF0A020A_1090711_en.pdf\"\u003eSICK 1090711 datasheet\u003c\/a\u003e. Related multiturn variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51124691632293,"sku":"TCG118","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/sick-eds35-2kf0a020a-40-1112142-service-guide.jpg?v=1794209897","url":"https:\/\/www.sparefaber.com\/de\/products\/sick-eds35-2kf0a020a-40-1112142","provider":"SpareFaber","version":"1.0","type":"link"}