{"product_id":"yaskawa-utmah-b15asb-absolute","title":"Yaskawa UTMAH-B15ASB 15-Bit Legacy Absolute Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for UTMAH-B15ASB installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Yaskawa UTMAH-B15ASB 15-Bit Legacy Absolute Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell documents TI-5000JX with the Yaskawa option and TI-5103 for checking the within-turn update. The article distinguishes that from the revolution-count update. Confirm the TI-5017 connector for the installed assembly. Check TI-3000JX support and fixture for the exact motor independently.\u003c\/p\u003e\n\u003ch2\u003eYaskawa UTMAH-B15ASB 15-Bit Legacy Absolute Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eUTMAH-B15ASB\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUTMAH-B15ASB\u003c\/th\u003e\n\u003ctd\u003eNamed on the Yaskawa USAREM-02CS2K motor assembly drawing.\u003c\/td\u003e\n\u003ctd\u003e15-bit legacy absolute family with startup update and A\/B feedback.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUTMAH-B15BSB\u003c\/th\u003e\n\u003ctd\u003eRelated model named by Mitchell. Confirm the exact motor and mechanical fit.\u003c\/td\u003e\n\u003ctd\u003eCompare backup, startup behavior and connection before choosing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUTOP family\u003c\/th\u003e\n\u003ctd\u003eSeparate Yaskawa feedback designation.\u003c\/td\u003e\n\u003ctd\u003eSome configurations have a distinct C-channel or incremental arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for UTMAH-B15ASB\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for UTMAH-B15ASB\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFitted example\u003c\/th\u003e\n\u003ctd\u003eYaskawa drawing for USAREM-02CS2K names UTMAH-B15ASB.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition per turn\u003c\/th\u003e\n\u003ctd\u003e32,768 counts for the documented 15-bit legacy family.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUpdate\u003c\/th\u003e\n\u003ctd\u003eWithin-turn startup position is sent as A\/B edges. Mitchell describes turn count on the A line at startup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBackup\u003c\/th\u003e\n\u003ctd\u003eExternal battery maintains retained information in the documented legacy system. Use the OEM battery procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/s3.amazonaws.com\/Icarus\/DOCUMENTS\/Yaskawa_Manuals_3544.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the Yaskawa motor assembly drawing to identify the fitted encoder housing and lead route. Compare the shaft and retention against the exact installed motor drawing before removal. Record the current motor position and reference under the OEM maintenance procedure.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eIn this Yaskawa legacy absolute system, the drive receives a position update at startup. Mitchell describes the within-turn value as a burst of A\/B quadrature edges and the revolution count as serial data on A. After startup, the drive follows A\/B movement. Distinguish this update scheme from a static parallel position word or a later Yaskawa all-serial encoder.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the USAREM motor and receiver wiring for A\/B, index, power, signal return and backup. Confirm the connector side and reference for the installed version. Preserve the retained position according to Yaskawa before disconnecting the backup path. Avoid transferring terminal numbering from a newer Sigma feedback connector.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eMitchell describes the TI-5017 legacy absolute cable with TI-5103. Match the actual connector and motor to the drawing before using the fixture. The internal motor pigtail and receiver harness are separate OEM assemblies. Obtain their numbers from the full USAREM order and drive.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStartup position is wrong but A\/B motion is clean\u003c\/th\u003e\n\u003ctd\u003eCheck battery status, startup update and original motor reference before changing parameters.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo feedback after a long power-off\u003c\/th\u003e\n\u003ctd\u003eVerify backup alarms, loaded supply and the OEM recovery sequence.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStart torque is wrong following replacement\u003c\/th\u003e\n\u003ctd\u003eCheck the exact encoder identity and mechanical or electrical commutation reference.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThe OEM bulletin shows UTMAH-B15ASB in a USAREM-02CS2K assembly. Mitchell discusses the broader legacy 15-bit family, including related Allen-Bradley applications. Confirm the original motor and feedback option before mapping a cross-brand lead.\u003c\/p\u003e\n\u003cp\u003eCompare a later serial generation by its complete model. \u003ca href=\"\/de\/products\/yaskawa-utsih-b13\"\u003eUTSIH-B13 technical guide\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eCapture the original encoder and motor reference and preserve backup before removal. Use the exact motor and drive routine to restore alignment and verify startup and motion. A family-level electrical-angle example needs the actual motor, pole count and approved method before use.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/s3.amazonaws.com\/Icarus\/DOCUMENTS\/Yaskawa_Manuals_3544.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Yaskawa AC Servo Drives bulletin, manufacturer-authored mirror. USAREM dimensional drawings identify the fitted encoder.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26724884325147-Yaskawa-Legacy-Encoders-Allen-Bradley-Generic-Incremental-C-Channel-and-12-15-bit-ABS\"\u003eMitchell legacy Yaskawa feedback\u003c\/a\u003e. Startup count, test scope and TI-5017\/TI-5103 arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26725981916699-Yaskawa-Motors\"\u003eMitchell Yaskawa motor guide\u003c\/a\u003e. Legacy feedback variants and separate motor run scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51125880488101,"sku":"TCG137","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/yaskawa-utmah-b15asb-absolute-service-guide.jpg?v=1794215844","url":"https:\/\/www.sparefaber.com\/de\/products\/yaskawa-utmah-b15asb-absolute","provider":"SpareFaber","version":"1.0","type":"link"}