{"product_id":"yaskawa-utsih-b13","title":"Yaskawa UTSIH-B13 13-Bit Incremental Serial Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for UTSIH-B13 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Yaskawa UTSIH-B13 13-Bit Incremental Serial Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eWe can trace Sigma serial feedback through the machine cable and identify whether the fault follows the drive input, motor harness or encoder. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell documents 13-bit incremental serial testing on supported TI-5000JX Athena setups. Select the exact feedback type and compare position, status and applicable commutation display. Verify the harness and installed test option first. Confirm TI-3000JX run support for the complete motor and firmware separately.\u003c\/p\u003e\n\u003ch2\u003eYaskawa UTSIH-B13 13-Bit Incremental Serial Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eUTSIH-B13\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUTSIH-B13\u003c\/th\u003e\n\u003ctd\u003eMitchell identifies the encoder model and Sigma families. Read the whole motor code and fitted label for the exact assembly.\u003c\/td\u003e\n\u003ctd\u003e13-bit incremental serial. Yaskawa's Sigma-II motor matrix lists feedback code A for SGMAH and SGMPH.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUTSIH-B16\u003c\/th\u003e\n\u003ctd\u003eDifferent incremental serial option in supported Sigma models.\u003c\/td\u003e\n\u003ctd\u003e16-bit selection. Confirm the motor and drive code before substituting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUTSAH-B17\u003c\/th\u003e\n\u003ctd\u003eSeparate absolute serial family. Check the OEM motor configuration.\u003c\/td\u003e\n\u003ctd\u003e17-bit absolute selection with separate turn retention requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eYaskawa maintains legacy Sigma-II application records. Ask Yaskawa for the exact UTSIH-B13 service order and supersession for the fitted motor.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for UTSIH-B13\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for UTSIH-B13\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEncoder class\u003c\/th\u003e\n\u003ctd\u003e13-bit incremental serial, 8,192 positions per turn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor option example\u003c\/th\u003e\n\u003ctd\u003eCode A in the documented Sigma-II SGMAH\/SGMPH order matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrive-side nominal supply\u003c\/th\u003e\n\u003ctd\u003eSGDH CN2 PG 5 V and PG 0 V per the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSignal path\u003c\/th\u003e\n\u003ctd\u003eSGDH CN2 PS and \/PS carry encoder serial data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor cable example\u003c\/th\u003e\n\u003ctd\u003eYaskawa JZSP-CMP00 family for applicable SGMAH and SGMPH motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/www.yaskawa.com\/delegate\/getAttachment?cmd=documents\u0026amp;documentId=YEA-SIA-S800-32.2\u0026amp;documentName=YEA-SIA-S800-32.2.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eIdentify the exact motor and brake configuration before accessing the feedback assembly. With all motion and supplies isolated, document the shaft location, coupling and encoder housing attachment. Inspect for bearing play or movement after a motor repair. Use the OEM service drawing for the exact encoder fit and adjustment.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe receiver exchanges position over Yaskawa's serial pair. The 13-bit incremental designation describes the motor feedback option. The position received by the drive is serial data. The drive's buffered pulse outputs to a host are a separate circuit.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThe table below applies to the SGDH Sigma-II SERVOPACK CN2 connector in Yaskawa section 3.5.2. Read the connector view and numbering in that drawing before back-probing through the approved test fixture. For the motor relay plug or encoder PCB, use the matching harness diagram.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"SGDH CN2 drive-side cavity functions\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSGDH CN2 drive-side cavity functions\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePins\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1 \/ 2\u003c\/th\u003e\n\u003ctd\u003ePG +5 V \/ PG 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3 \/ 4\u003c\/th\u003e\n\u003ctd\u003eBattery + \/ − for applicable absolute configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e5 \/ 6\u003c\/th\u003e\n\u003ctd\u003ePS \/ inverse PS, encoder serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eConfirm the fitted feedback option before wiring any backup circuit.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eYaskawa lists shielded JZSP-CMP00 cables for SGMAH and SGMPH. The wiring manual identifies JZSP-CMP9-1 and JZSP-CMP9-2 as the applicable mating plug\/socket references for the specified connector arrangement. Match the motor suffix, connector and cable length. The internal lead is an OEM assembly item.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrive reports encoder communication loss\u003c\/th\u003e\n\u003ctd\u003eCheck SGDH CN2, loaded supply and PS pair. Confirm the exact motor and receiver type.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWrong position step or count behaviour\u003c\/th\u003e\n\u003ctd\u003eCompare the 13-bit selection to the motor order code and read the serial diagnostics.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent fault during cable movement\u003c\/th\u003e\n\u003ctd\u003eTrace the relay connector and the disconnected encoder cable. Inspect contacts, screen and strain relief.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault starts after the encoder is disturbed\u003c\/th\u003e\n\u003ctd\u003eCheck mechanical seating, orientation, the motor's reference and the OEM commissioning procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eMitchell identifies UTSIH-B13 in Sigma-II, III and V. Yaskawa documents the 13-bit option A on relevant SGMAH\/SGMPH motors. Confirm the exact suffix and drive family. See the \u003ca href=\"\/de\/products\/yaskawa-utsah-b17\"\u003eUTSAH-B17 guide\u003c\/a\u003e for the separate absolute device.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord the original motor and drive data and the feedback reference before removing the encoder. Identify which values the OEM stores in the drive or encoder for the fitted option. Use the appropriate motor procedure and verify direction, commutation and datum after service.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.yaskawa.com\/delegate\/getAttachment?cmd=documents\u0026amp;documentId=YEA-SIA-S800-32.2\u0026amp;documentName=YEA-SIA-S800-32.2.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Yaskawa YEA-SIA-S800-32.2. Table 1.2 identifies feedback option A. Section 3.5.2 shows SGDH CN2 and section 5.8.1 describes the encoder cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.yaskawa.com\/products\/motion\/sigma-5-servo-products\/rotary-servo-motors\/sgmah-sigma-ii\"\u003eManufacturer reference\u003c\/a\u003e. Yaskawa SGMAH Sigma II series. Compare the encoder identifier in the complete order code.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/8432774627611-Yaskawa-Serial-Encoder-Identification\"\u003eMitchell Yaskawa serial identification\u003c\/a\u003e. Motor feedback letter and UTSIH-B13 model.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/13505685409307-Yaskawa-Serial-Encoder-Testing\"\u003eMitchell Yaskawa serial bench testing\u003c\/a\u003e. Serial count and position checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.yaskawa.com\/downloads\/search-index\/details?docnum=UWR00282\u0026amp;showType=details\"\u003eYaskawa JZSP-CMP00 drawing record\u003c\/a\u003e. Motor-side encoder cable drawing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51124703985829,"sku":"TCG125","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/yaskawa-utsih-b13-service-guide.jpg?v=1794210419","url":"https:\/\/www.sparefaber.com\/de\/products\/yaskawa-utsih-b13","provider":"SpareFaber","version":"1.0","type":"link"}