{"product_id":"allen-bradley-842e-mip1ba","title":"Allen-Bradley 842E-MIP1BA EtherNet\/IP Encoder  | Technical Guide| Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eLink lights on, but the controller has no usable position?\u003c\/strong\u003e SpareFaber can visit your UAE site to check the 842E power, coupling, Ethernet link and controller setup. Ask about a bench test or replacement review for your exact series.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Allen-Bradley 842E-MIP1BA EtherNet\/IP Encoder technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the complete catalogue number and series, controller and project revision, module fault and LED states. Record the current position reference and scaling. Include photos of the coupling and the three rear ports. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA compatible EtherNet\/IP engineering station can check identity, network link, cyclic I\/O, scaling and preset on an isolated setup. A qualified technician can compare supply at the load and read the Net, Mod, Link and Encoder LEDs against the manual. Exact Mitchell TI-5000JX or TI-3000JX support was not verified for this standalone EtherNet\/IP encoder. \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/842e-um001_-en-p.pdf\"\u003eRockwell 842E setup, diagnostics and network manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eAllen-Bradley 842E-MIP1BA EtherNet\/IP Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCopy the entire catalogue code and the device series. In \u003cstrong\u003e842E-MIP1BA\u003c\/strong\u003e, M identifies multiturn, IP identifies EtherNet\/IP, 1 is the 9.52 mm solid shaft code and B specifies the M12 connector. The order suffix and the separate hardware-series marking matter when choosing a firmware and EDS.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Rockwell 842E order-code examples\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eRockwell 842E order-code examples\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eCatalogue code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeasurement\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical difference\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e842E-MIP1BA\u003c\/th\u003e\n\u003ctd\u003eEtherNet\/IP multiturn, up to 30-bit total position\u003c\/td\u003e\n\u003ctd\u003e9.52 mm (3\/8 in) solid shaft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e842E-SIP1BA\u003c\/th\u003e\n\u003ctd\u003eEtherNet\/IP singleturn, up to 18-bit singleturn\u003c\/td\u003e\n\u003ctd\u003e9.52 mm (3\/8 in) solid shaft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e842E-MIP2BA\u003c\/th\u003e\n\u003ctd\u003eEtherNet\/IP multiturn\u003c\/td\u003e\n\u003ctd\u003e9.52 mm solid shaft with a flat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e842E-MIP8BA\u003c\/th\u003e\n\u003ctd\u003eEtherNet\/IP multiturn\u003c\/td\u003e\n\u003ctd\u003eØ10 mm hollow shaft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/in\/842e-in001_-en-p.pdf\"\u003eRockwell 842E catalogue codes (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.rockwellautomation.com\/en-us\/products\/details.842e-mip1ba.html\"\u003eExact 842E-MIP1BA record\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eRockwell marks \u003cstrong\u003e842E-MIP1BA discontinued on 15 December 2023\u003c\/strong\u003e and identifies a functional replacement category. Its migration note covers the 843E family. Confirm the required shaft, topology, firmware and controller configuration before selecting a replacement. Reviewed 7 November 2026. \u003ca href=\"https:\/\/www.rockwellautomation.com\/en-us\/products\/details.842e-mip1ba.html\"\u003eRockwell exact lifecycle record\u003c\/a\u003e · \u003ca href=\"https:\/\/support.rockwellautomation.com\/app\/answers\/answer_view\/a_id\/1137703\/~\/842e-lifecycle-status-announcement-%26-migration-to-the-843e-\"\u003eRockwell 842E-to-843E migration note\u003c\/a\u003e · \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/843-um001_-en-p.pdf\"\u003e843E\/843ES user manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"842E-MIP1BA and scoped 842E-MIP user manual\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003e842E-MIP1BA and scoped 842E-MIP user manual\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd\u003eOptical absolute multiturn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003eUp to 18 bits singleturn (262,144 steps), 12 bits multiturn (4096 revolutions), 30 bits total. Scaling depends on controller settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e10–30 V DC per the exact product record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNetwork\u003c\/th\u003e\n\u003ctd\u003eEtherNet\/IP with IEEE 1588 per exact record. Two M12 network ports and a separate power port.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMount\u003c\/th\u003e\n\u003ctd\u003eSolid 9.52 mm shaft, encoder with its own bearings. Use the solid-shaft outline and flexible coupling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse the exact catalogue supply rating. Some general 842E wiring publications show a different upper limit. Confirm the label and relevant publication before energizing the device. \u003ca href=\"https:\/\/www.rockwellautomation.com\/en-us\/products\/details.842e-mip1ba.html\"\u003eExact Rockwell electrical data\u003c\/a\u003e · \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/842e-um001_-en-p.pdf\"\u003e842E operating principle (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eSecure the encoder flange to its bracket and use a suitable flexible coupling between the machine and the 3\/8 in solid encoder shaft. Align radial, axial and angular position according to the coupling manufacturer. Rockwell warns that a rigid coupling can damage the bearings. Check for slipping hubs, loose mounting screws and excessive preload before adjusting network parameters. \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/in\/842e-in001_-en-p.pdf\"\u003eSolid-shaft and coupling drawings (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe encoder reads its optical position and sends a numeric value through EtherNet\/IP. The controller’s I\/O connection and encoder profile determine which data it receives. A link LED verifies the physical Ethernet connection, while the controller’s module status verifies cyclic I\/O. Compare the raw position with the scaled machine value and preset before replacing the encoder.\u003c\/p\u003e\n\u003cp\u003eRockwell distinguishes Series A from Series B firmware capability. Check the actual nameplate series, EDS and project hardware entry before downloading or migrating a configuration. \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/842e-um001_-en-p.pdf\"\u003eRockwell encoder overview and EDS setup (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"842E separate M12 power and Ethernet ports\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003e842E separate M12 power and Ethernet ports\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePort\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePin assignment\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eConnection check\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower M12\u003c\/th\u003e\n\u003ctd\u003e1 supply positive, 3 DC return. 2 and 4 unused.\u003c\/td\u003e\n\u003ctd\u003eIdentify the power port and correct cordset before applying voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLink 1 \/ Link 2, D-coded Ethernet\u003c\/th\u003e\n\u003ctd\u003e1 TX+, 3 TX−. 2 RX+, 4 RX−.\u003c\/td\u003e\n\u003ctd\u003eUse shielded industrial Ethernet cable and the documented connector face.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse Link 1 for the documented star configuration and follow the manual for linear or ring networks. The connectors serve different circuits despite both being M12. \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/pp\/842e-pp001_-en-p.pdf\"\u003eRockwell port layout and pinout (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/842e-um001_-en-p.pdf\"\u003eRockwell wiring and topology (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Rockwell external mating leads\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eRockwell external mating leads\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePart number\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRole\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e889D-F4AC-2\u003c\/th\u003e\n\u003ctd\u003e4-pin DC Micro QD power cordset, 2 m in the installation instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e889D-F4ACDM-2\u003c\/th\u003e\n\u003ctd\u003e4-pin DC Micro QD power patchcord, 2 m in the installation instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1585D-M4TBJM-2\u003c\/th\u003e\n\u003ctd\u003eM12 D-coded male\/male industrial Ethernet patchcord listed in 842E-IN001. Confirm the required length and endpoints.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThis encoder mounts externally, so the service cable is the machine or network lead. Use the approved lead for the port and preserve the intended shield and bend radius. \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/in\/842e-in001_-en-p.pdf\"\u003eRockwell Suggested Mating Cables (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolate the machine before disconnecting the encoder or altering the coupling.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect.\u003c\/strong\u003e Check port labels, bent pins, liquid or debris, plug retention, cable support, loose flange and coupling slip. Record LED state before isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck disconnected leads.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Use a cable tester rated for the Ethernet link when pair quality is suspect.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck power and link separately.\u003c\/strong\u003e A qualified technician can fit an approved breakout while off and measure DC across power pins 1 and 3 under load. Check Link and Mod LEDs, IP settings and duplicate addresses. Keep uncommissioned equipment off the live network until its address is verified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the position path.\u003c\/strong\u003e Link with no I\/O suggests address, EDS, module or controller configuration. Good I\/O with wrong travel suggests shaft slip, scaling, preset or direction. Intermittency with movement calls for checking the connector and cable.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eRockwell documents configuring 842E in RSLogix 5000 with an EDS and encoder module settings. Match the controller and hardware series to the applicable chapter. The 842E-CM integrated-motion model uses a separate manual and order code. The standard 842E-MIP guide applies to the named product. \u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/842e-um001_-en-p.pdf\"\u003eRockwell controller integration (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.rockwellautomation.com\/en-us\/products\/hardware\/allen-bradley\/motion-control\/encoders\/absolute\/842e-843e-ethernet-ip.html\"\u003e842E, 842E-CM and 843E documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord the machine datum, direction, step scaling, total range and preset before replacement. Restore only the configuration authorized for the same axis. Verify a known position, direction and position across a turn boundary before enabling motion. If migrating to 843E, compare mechanical fit and I\/O mapping and recommission the position reference. A separate motor commutation offset follows the motor maker’s procedure.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/in\/842e-in001_-en-p.pdf\"\u003eRockwell 842E-IN001 installation instructions (PDF)\u003c\/a\u003e. Model codes, mounting, couplings and suggested mating cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/842e-um001_-en-p.pdf\"\u003eRockwell 842E-UM001 user manual (PDF)\u003c\/a\u003e. Power, network, hardware series, EDS, diagnostics and preset.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/pp\/842e-pp001_-en-p.pdf\"\u003eRockwell 842E-PP001 product profile (PDF)\u003c\/a\u003e. Separate Ethernet and power connector assignments.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/um\/843-um001_-en-p.pdf\"\u003eRockwell 843-UM001 migration target manual (PDF)\u003c\/a\u003e. Check the relevant 843E configuration when selecting a replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading (Est. 2003]","offers":[{"title":"Default Title","offer_id":51117085753509,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/Allen-Bradley842E-MIP1BAEtherNetIPEncoderTechnicalGuideServiceVisitforInstallation_Repair_Alignment.jpg?v=1794123374","url":"https:\/\/www.sparefaber.com\/products\/allen-bradley-842e-mip1ba","provider":"SpareFaber","version":"1.0","type":"link"}