{"product_id":"amci-r11x-j10-7-brushless-resolver","title":"AMCI R11X-J10\/7 Size 11 Brushless Resolver | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for R11X-J10\/7 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"AMCI R11X-J10\/7 Size 11 Brushless Resolver technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell's Generic Resolvers chapter documents the TI-5000JX J12 path and angle, vector level and phase observations. Confirm that the tester can supply the AMCI rating at the required load and that the adapter follows the exact lead drawing. Verify any TI-3000JX run separately using the actual motor, fixture, drive limits and tester profile. A resolver-only signal check can isolate the feedback from the machine loom.\u003c\/p\u003e\n\u003ch2\u003eAMCI R11X-J10\/7 Size 11 Brushless Resolver technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eR11X-J10\/7\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eR11X-J10\/7\u003c\/th\u003e\n\u003ctd\u003eSize 11 housed resolver. Match the J10 shaft and servo mounting drawing.\u003c\/td\u003e\n\u003ctd\u003eOne electrical cycle per turn, 7.0 V AC at 5 kHz, 0.95 transformation ratio.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eR11X-J12\/7\u003c\/th\u003e\n\u003ctd\u003eJ12 is a different shaft build. Check coupling bore and installed stack.\u003c\/td\u003e\n\u003ctd\u003eAMCI lists 1×, 5 kHz and a 0.95 ratio for this variant.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e11BRCX-300-J\/7\u003c\/th\u003e\n\u003ctd\u003eHarowe part listed by AMCI against R11X-J10\/7. Compare pilot, shaft and retention.\u003c\/td\u003e\n\u003ctd\u003eCheck the Harowe lead drawing and the receiver. AMCI lists this as a compatible part.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eR11X-2J10\/20\u003c\/th\u003e\n\u003ctd\u003eRelated size 11 J10 resolver. Verify the full label and drawing.\u003c\/td\u003e\n\u003ctd\u003eTwo electrical cycles per shaft revolution. Requires a receiver configured for that resolver speed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eAMCI's product record identifies R11X-J10\/7 and the Harowe cross-reference. Current production and lead time for the exact order code are unconfirmed.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for R11X-J10\/7\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for R11X-J10\/7\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExcitation\u003c\/th\u003e\n\u003ctd\u003e7.0 V AC at 5,000 Hz in the AMCI R11X-J10\/7 engineering table. Use the documented source and measurement convention.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransformation ratio\u003c\/th\u003e\n\u003ctd\u003e0.95 for this order code, specified as the output-to-excitation ratio at the defined peak-coupling position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolver speed\u003c\/th\u003e\n\u003ctd\u003e1×. The sine\/cosine vector makes one electrical cycle per shaft turn.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePackage\u003c\/th\u003e\n\u003ctd\u003eSize 11 servo mount. Use the model drawing for pilot, shaft and protrusion dimensions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003eA resolver-to-digital input rated for this excitation, ratio, phase and winding arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.amci.com\/files\/3414\/4831\/4742\/1731-1732-1733-1734-1741-1742-1743-1744-plc5-resolver-interface-plc-pac-module-user-manual.pdf#page=7\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eLocate the resolver by its servo pilot and use the specified clamps or OEM retention. Check shaft diameter and insertion depth against the coupling drawing. Align the drive and resolver shafts with the supported coupling so the resolver bearings carry no assembly preload. A coupling that slips can shift angle while all three windings still measure normally.\u003c\/p\u003e\n\u003cp\u003eCheck witness marks, looseness and evidence of rubbing after isolation. Obtain the resolver and machine drawings before adjusting shaft engagement or clamp torque.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eA resolver is a rotary transformer. The receiver drives R1\/R2 with an AC carrier. The shaft angle changes the signed carrier amplitudes in the sine and cosine windings. The receiver demodulates the two channels and combines their signed values to determine the angle within the turn. The two output pairs are analogue winding signals. Measure them with the documented excitation reference and input loading.\u003c\/p\u003e\n\u003cp\u003eA DC meter can find an open isolated harness. The demodulated vector and angle under a controlled turn are more informative about winding balance, direction and dropouts.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eAMCI's resolver module manual figure on PDF page 7 shows the standard six-lead R\/S winding identification. The table is for the AMCI leads in that figure. Check the supplied lead drawing before applying colours to a Harowe or OEM-built harness.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"AMCI six-lead resolver convention\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eAMCI six-lead resolver convention\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eWinding\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eLead pair\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExcitation\u003c\/th\u003e\n\u003ctd\u003eR1 red\/white, R2 black\/white\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSine\u003c\/th\u003e\n\u003ctd\u003eS1 red, S3 black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCosine\u003c\/th\u003e\n\u003ctd\u003eS2 yellow, S4 blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse the receiver's termination and screen drawing for the far end. Keep the three pairs separate and check the phase designations at each end.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe standard resolver has flying winding leads. The machine loom ends at the actual resolver interface or drive connector. Order it by the machine drawing and record both ends, cable run and screen bond. Verify each paired conductor before repinning. AMCI module connector diagrams apply to their named module, not to a generic motor bulkhead.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExcitation absent\u003c\/th\u003e\n\u003ctd\u003eCheck the receiver settings and source first. Compare its carrier at the documented breakout and the resolver end in the approved setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOne channel low or missing\u003c\/th\u003e\n\u003ctd\u003eTrace that isolated pair, then check the signed waveform and compare both channels at equivalent shaft positions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAngle is reversed or wraps twice\u003c\/th\u003e\n\u003ctd\u003eCheck winding polarity, receiver direction and resolver speed. Confirm the full code and inspect the coupling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAngle jumps after load changes\u003c\/th\u003e\n\u003ctd\u003eInspect coupling slippage or play and repeat a slow controlled turn with the receiver logging angle and amplitude.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThis guide covers the standalone housed AMCI resolver and its documented Harowe cross-reference. A motor with this type of feedback may need separate instructions for excitation, poles and commutation reference. Compare the nameplate, resolver tag and feedback receiver before treating it as an OEM motor replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord the original shaft datum and sign before disturbing the coupling. Set reference according to the controller or motor procedure. For commutated motors, validate the motor's electrical reference with the OEM method and the installed resolver speed. The resolver windings contain no digital motor-memory record to copy.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.amci.com\/files\/3414\/4831\/4742\/1731-1732-1733-1734-1741-1742-1743-1744-plc5-resolver-interface-plc-pac-module-user-manual.pdf#page=7\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.amci.com\/plc-automation-products\/r11-size-11-brushless-resolver-sensors\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.amci.com\/plc-automation-products\/r11-size-11-brushless-resolver-sensors\"\u003eAMCI R11 electrical and cross-reference tables\u003c\/a\u003e. Use the exact J10\/7 row and the family mechanical drawing.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26578514023963-Generic-Resolvers\"\u003eMitchell generic resolver testing\u003c\/a\u003e. See setup, phase, vector level and resolver speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51119404515493,"sku":"TCG97","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/amci-r11x-j10-7-brushless-resolver-service-guide.jpg?v=1794147974","url":"https:\/\/www.sparefaber.com\/products\/amci-r11x-j10-7-brushless-resolver","provider":"SpareFaber","version":"1.0","type":"link"}