{"product_id":"baldor-rf0001-resolver","title":"ABB Baldor RF0001 One-Speed Brushless Resolver | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for RF0001 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"ABB Baldor RF0001 One-Speed Brushless Resolver technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eOn site, we trace the resolver excitation and returns through the motor cable. Bench evaluation can compare winding and signal behaviour with a known reference when the assembly data are available. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eAn approved resolver bench setup can measure the excitation and compare sine\/cosine amplitudes and phase as the shaft moves. A winding check uses the OEM resistance criteria with the resolver disconnected from its receiver. Keep the supply off until the excitation specification and pin map are verified.\u003c\/p\u003e\n\u003cp\u003eTI-5901 identifies the family-level lead. Verify the exact resolver module and test profile before a TI-5000JX check, and independently verify motor run support and fixtures for TI-3000JX.\u003c\/p\u003e\n\u003ch2\u003eABB Baldor RF0001 One-Speed Brushless Resolver technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eRF0001\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRF0001\u003c\/th\u003e\n\u003ctd\u003eOne-speed brushless resolver on BSM80C-4150AA. Baldor OEM part number.\u003c\/td\u003e\n\u003ctd\u003eAnalog excitation and two return windings. Supplier ordering code is open.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOE0323A02\u003c\/th\u003e\n\u003ctd\u003eDifferent feedback assembly on BSM80C-275RF.\u003c\/td\u003e\n\u003ctd\u003eABZ\/UVW encoder with a 16-pin feedback outlet and a different test path.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe OEM parts list identifies RF0001. Confirm the exact service part’s supply and supersession status with Baldor for the motor serial number.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for RF0001\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for RF0001\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolver type\u003c\/th\u003e\n\u003ctd\u003eBrushless, one speed, from Baldor's BSM80C-4150AA parts list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eListed resolver diameter\u003c\/th\u003e\n\u003ctd\u003e1.4165 in, approximately 36.0 mm. Verify fit and tolerances on the actual resolver drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor feedback connector\u003c\/th\u003e\n\u003ctd\u003eWD1455A01, M23 threaded, 12-pin on the documented motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor-side lead\u003c\/th\u003e\n\u003ctd\u003eLD2200A08 is listed with the resolver in the same bill of materials.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical data still needed\u003c\/th\u003e\n\u003ctd\u003eExact excitation amplitude and frequency, transformation ratio, winding resistance and connector pin assignments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/www.baldorvip.com\/Product\/InfoPacketExternal\/?id=BSM80C-4150AA\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe Baldor packet lists a C-shaped resolver clamp in the BSM80C assembly. The resolver diameter helps identify the unit. It does not determine the shaft register, rotor retention, clearance or clamp setting. Before removing anything, record the original rotor\/stator relationship, location and orientation.\u003c\/p\u003e\n\u003cp\u003eOn an isolated motor, look for witness marks, clamp movement or evidence of rubbing. Compare the housing and connector placement with the Baldor outline. Use the OEM service drawing to set the internal fit.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe receiver excites a reference winding with an AC carrier. The two return signals vary with shaft angle, and the receiver decodes their ratio and signs. One speed means one electrical position cycle per mechanical revolution. Open excitation can take out both returns, so check that path before attributing two missing outputs to the resolver.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eIdentify the excitation pair, sine return pair, cosine return pair and the shield termination from the exact motor wiring sheet. The published parts list establishes the 12-pin M23 connector identity. It does not assign the individual cavity numbers. Match the drawing view and harness at the motor and the drive before applying excitation.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Resolver wiring groups to trace\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eResolver wiring groups to trace\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eCircuit\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCheck\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExcitation\u003c\/th\u003e\n\u003ctd\u003eVerify the OEM carrier requirement and the receiver’s excitation path.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSIN \/ COS\u003c\/th\u003e\n\u003ctd\u003eCheck each differential winding pair with the documented polarity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShield and shell\u003c\/th\u003e\n\u003ctd\u003eVerify the specified bonds on the actual harness.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe BSM80C-4150AA bill of materials names LD2200A08 and the WD1455A01 feedback socket. Confirm the serviceability of the lead and actual pinout with Baldor using the motor spec. Mitchell lists TI-5901 for the BSM 12-pin M23 resolver family. Confirm the fitted motor wiring before connecting it.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoth returns missing\u003c\/th\u003e\n\u003ctd\u003eConfirm drive excitation arrives at the motor and the common connector path is intact. Verify the receiver setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOnly one return is absent or unstable\u003c\/th\u003e\n\u003ctd\u003eWith the harness isolated, check the corresponding pair, crimp and shorts. A specialist can compare the two modulated returns under approved excitation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRepeatable angle error after motor repair\u003c\/th\u003e\n\u003ctd\u003eCheck resolver retention, return polarity, direction and the drive’s commutation reference before condemning the windings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault follows temperature or movement\u003c\/th\u003e\n\u003ctd\u003eRecord conditions and check cable strain, connector retention and motor mechanical play.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eBaldor spec S2P166W071 for BSM80C-4150AA documents this resolver. The BSM name also appears on encoder-equipped builds, including \u003ca href=\"\/products\/baldor-oe0323a02-abz-uvw\"\u003eBSM80C-275RF with OE0323A02\u003c\/a\u003e. Match the motor's order code, connector and drive feedback selection.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eThe resolver is passive. Motor commutation depends on the installed mechanical relationship, winding polarity and receiver setup. Capture the original reference before moving the stator or rotor. The exact Baldor setting and verification method are needed before replacing or rotating the assembly.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.baldorvip.com\/Product\/InfoPacketExternal\/?id=BSM80C-4150AA\"\u003eMain technical PDF\u003c\/a\u003e. Parts list and outline for BSM80C-4150AA, spec S2P166W071.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.baldor.com\/catalog\/BSM80C-4150AA\"\u003eManufacturer reference\u003c\/a\u003e. Baldor motor catalogue reference for the documented RF0001 build.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\"\u003eMitchell manufacturer cable index\u003c\/a\u003e. Baldor BSM TI-5901 entry and connector family.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/sections\/26370850277403-TI-5000JX-Training-Manual\"\u003eMitchell training manual\u003c\/a\u003e. Resolver measurement background and test-platform documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51124687503525,"sku":"TCG114","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/baldor-rf0001-resolver-service-guide.jpg?v=1794209510","url":"https:\/\/www.sparefaber.com\/products\/baldor-rf0001-resolver","provider":"SpareFaber","version":"1.0","type":"link"}