{"product_id":"baumuller-ds2-100lo54w-resolver-a-technical-guide","title":"Baumüller DS2-100LO54W Resolver A Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sparefaber-encoder-guide\"\u003e\n\u003cp\u003e\u003cstrong\u003eBaumüller DS2-100LO54W · Resolver A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE site visits and send-in evaluation for the Baumüller DS2-100LO54W. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e\u003c\/p\u003e\n\u003cnav aria-label=\"Guide sections\"\u003e\u003cp\u003e\u003ca href=\"#identify\"\u003eFind your part\u003c\/a\u003e · \u003ca href=\"#testing\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mechanical-fit\"\u003eMechanical fit\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#availability\"\u003eAvailability\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDocuments\u003c\/a\u003e · \u003ca href=\"#faq\"\u003eFAQ\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the motor nameplate, complete part number and fitted feedback label. Liquid-cooled DS2-100 LO stack. M0 from OEM continuous rating table. Use resolver A and the actual DS2-100 holder and drawing.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eWhat to identify\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCatalogue reference\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor base\u003c\/td\u003e\n\u003ctd\u003eDS2-100LO54W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eLiquid cooled, IP54 catalogue design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback code\u003c\/td\u003e\n\u003ctd\u003eA, standard resolver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eInclude any special suffixes and clear photos of the mating connectors and the feedback mount.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"testing\"\u003e\u003ch2\u003eWhat specialist testing can establish\u003c\/h2\u003e\n\u003cp\u003eVerify the standard A resolver identity from the DS2 order. Use a suitable verified resolver fixture and compare cyclic reference and secondaries with the actual waveform and supported excitation.\u003c\/p\u003e\n\u003cp\u003eSpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eReference specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCatalogue value\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eScope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStall torque reference\u003c\/td\u003e\n\u003ctd\u003e130 N·m\u003c\/td\u003e\n\u003ctd\u003eM0 for the LO stack. Retain actual winding, cooler and drive conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolver A\u003c\/td\u003e\n\u003ctd\u003eOne pole pair, catalogue excitation 5 kHz \/ 7 V RMS\u003c\/td\u003e\n\u003ctd\u003eReference condition from OEM. Confirm actual fitted order and intended test hardware.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal type\u003c\/td\u003e\n\u003ctd\u003eExcited resolver with sine and cosine secondary output\u003c\/td\u003e\n\u003ctd\u003eIdentify winding pairs and polarity with the correct diagram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mechanical-fit\"\u003e\u003ch2\u003eMechanical fit\u003c\/h2\u003e\n\u003cp\u003eUse the liquid-cooled DS2-100 LO stack drawing. Compare DS2\/DS2+ winding speed, mount, shaft, brake length, terminal box and fitted feedback adapter. Keep the coolant connection accessible.\u003c\/p\u003e\n\u003cp\u003eCheck the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eTrace excitation, sine and cosine secondary pairs from the standard resolver A diagram and motor bulkhead drawing. Check direction and screen against the exact order.\u003c\/p\u003e\n\u003cp\u003eIdentify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"cables\"\u003e\u003ch2\u003eInternal wiring and machine cables\u003c\/h2\u003e\n\u003cp\u003eUse the selected DS2-100 drawing to identify terminal box and feedback route on the actual motor. Verify cable construction and receiver, including the cooler, thermal and possible brake circuits.\u003c\/p\u003e\n\u003cp\u003eSend clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObserved symptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to check\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent feedback on a hot motor\u003c\/td\u003e\n\u003ctd\u003eCorrelate cooler and winding\/temperature records with encoder supply or resolver signals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanically similar donor assembly\u003c\/td\u003e\n\u003ctd\u003eCompare exact LO stack, revision and feedback holder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eServo trips after assembly\u003c\/td\u003e\n\u003ctd\u003eVerify original reference, sensor signal and motor data for the fitted order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord original sensor orientation, fitted code and drive identification. Compare the reference before and after service with the documented drive process and preserve the machine origin.\u003c\/p\u003e\n\u003cp\u003eCheck that the cyclic resolver position agrees across slow, controlled repeat observations. Verify original polarity and scaling.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and availability\u003c\/h2\u003e\n\u003cp\u003eRequest availability against the complete DS2-100LO54W order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eBaumüller drive application with the exact DS2\/DS2+ order, actual cooling configuration and feedback option.\u003c\/p\u003e\n\u003cp\u003eSend the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings and manuals\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.baumueller.com\/media\/downloads\/BMN_DS2-100-200_en_24.pdf\"\u003eBaumüller DS2-100–200 technical documentation\u003c\/a\u003e. DS2-100\/DS2+100 liquid-cooled data and DS2-100 outline, 3.2 encoder data for resolver A and ECN 1313 \/ EQN 1325.\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e\u003csection id=\"faq\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should I send for an evaluation?\u003c\/summary\u003e\u003cp\u003eSend the complete DS2-100LO54W order, feedback label, connectors at both ends, drive order and the original fault or alarm.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan I match the feedback from the motor frame?\u003c\/summary\u003e\u003cp\u003eUse the order information above, then compare the actual feedback label, signals, drawings and reference procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan you check the motor at our site?\u003c\/summary\u003e\u003cp\u003eRequest a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003cdiv id=\"enquiry\"\u003e\n\u003ch2\u003eRequest service\u003c\/h2\u003e\n\u003cp\u003eSend the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Baumüller","offers":[{"title":"Default Title","offer_id":51311076180133,"sku":"TCG1983","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/baumuller-ds2-100lo54w-resolver-a-technical-guide-cover.jpg?v=1795541040","url":"https:\/\/www.sparefaber.com\/products\/baumuller-ds2-100lo54w-resolver-a-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}