{"product_id":"bosch-rexroth-mkd071b-061-k","title":"Bosch Rexroth Indramat MKD071B-061 K Servo Feedback  | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eFeedback alarm on an Indramat MKD071B-061?\u003c\/strong\u003e SpareFaber can visit your UAE site to check the drive alarm, X3 feedback cable and motor identification. For send-in diagnosis, we can evaluate the resolver and digital board separately and record the alignment before disturbing the original assembly.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Bosch Rexroth Indramat MKD071B-061 K Servo Feedback technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the full motor type code and material number, drive type and firmware, exact alarm, when it first appeared and photos of the connection box. Include the original motor and feedback board for alignment work. Arrange packing and intake before shipping. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell documents two distinct TI-5000JX setups for the MKD\/MKE board assembly. The TI-5924 resolver lead is for signal and existing alignment checks. The TI-5040 revision C with TI-5104 adapter is the memory setup, with the resolver disconnected from the PCB while the assembly is safely off. Mitchell also documents a separate TI-3000JX generic resolver run test using the TI-5924 and the confirmed motor and excitation settings. That run test exercises the resolver and motor. Verify board communication on the intended Rexroth system as well. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/5247936417051-Indramat-Rexroth-MKD-MKE-Resolver-and-Digital-Board-Test-Procedures\"\u003eMitchell MKD\/MKE bench test and alignment procedure\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eBosch Rexroth Indramat MKD071B-061 K Servo Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eRead the motor plate, including the three characters after the winding code and the final two characters. In \u003cstrong\u003eMKD071B-061-KP0-KN\u003c\/strong\u003e, 071 is the size, B the length and 061 the winding. The first K selects multiturn feedback. P identifies the keyed driven shaft, 0 omits the holding brake and the last KN identifies the standard junction-box build. The two occurrences of K describe different things.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"MKD071B-061 examples decoded using Rexroth figure 8-5\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eMKD071B-061 examples decoded using Rexroth figure 8-5\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFull motor code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFeedback option\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical and connection differences\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMKD071B-061-KP0-KN\u003c\/th\u003e\n\u003ctd\u003eK resolver with integrated multiturn absolute feedback\u003c\/td\u003e\n\u003ctd\u003eKeyed driven shaft, no holding brake, standard connection box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMKD071B-061-KP1-KN\u003c\/th\u003e\n\u003ctd\u003eK resolver with integrated multiturn absolute feedback\u003c\/td\u003e\n\u003ctd\u003eKeyed driven shaft, 5 Nm holding-brake option, standard connection box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMKD071B-061-GG0-KN\u003c\/th\u003e\n\u003ctd\u003eG resolver feedback, separate from the K multiturn option\u003c\/td\u003e\n\u003ctd\u003ePlain driven shaft, no holding brake, standard connection box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.magnaproducts.com\/wp-content\/uploads\/2019\/09\/Indramat-MKD-Project-Planning-Manual_compressed.pdf#page=63\"\u003eRexroth MKD071 ordering code (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/5247936417051-Indramat-Rexroth-MKD-MKE-Resolver-and-Digital-Board-Test-Procedures\"\u003eMitchell G\/K board comparison\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe Rexroth project-planning manual is a legacy installed-base reference. Exact production, repair exchange and replacement status for a given material number require a current Rexroth lookup. Record the number from the nameplate. \u003ca href=\"https:\/\/www.boschrexroth.com\/ics\/spc\/?Language=EN\"\u003eRexroth spare-parts lookup\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"MKD071B-061 and feedback option K\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eMKD071B-061 and feedback option K\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eItem\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor poles\u003c\/th\u003e\n\u003ctd\u003e4 pole pairs (8 poles) for winding 061. This is a motor value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCharacteristic \/ maximum motor speed\u003c\/th\u003e\n\u003ctd\u003e4500 rpm characteristic, 6000 rpm maximum in Rexroth figure 8-3. Use the motor and drive limits for the actual installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback architecture\u003c\/th\u003e\n\u003ctd\u003eK is resolver feedback with an integrated multiturn absolute encoder. Mitchell describes a battery, a magnet wheel and pickups on the K board.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003eThe standard KN build in this guide has the 10-position motor-side X3 connection box. Its feedback cable is distinct from X1 motor power.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrake option\u003c\/th\u003e\n\u003ctd\u003eKP0 has no brake. KP1 selects the 5 Nm holding brake. Mechanically secure the load before either version is disturbed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExcitation and board supply\u003c\/th\u003e\n\u003ctd\u003eConfirm with the drive, board revision and documented service setup. Mitchell's test adapter is specific to its memory procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.magnaproducts.com\/wp-content\/uploads\/2019\/09\/Indramat-MKD-Project-Planning-Manual_compressed.pdf#page=61\"\u003eRexroth 061 motor data (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/5247936417051-Indramat-Rexroth-MKD-MKE-Resolver-and-Digital-Board-Test-Procedures\"\u003eMitchell board and magnet-wheel notes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe resolver is inside the motor at the feedback end. Record the original connector position, orientation of the resolver parts, magnet wheel and board, and their mounting references before loosening anything. Inspect for a loose stator, shifted rotor or wheel, contamination, and a trapped lead when the unit is safely apart. The driven-shaft dimensions in Rexroth chapter 8 help identify the motor. Internal rotor\/stator clearance, fastener torque and reassembly instructions must come from the exact service drawing or procedure. \u003ca href=\"https:\/\/www.magnaproducts.com\/wp-content\/uploads\/2019\/09\/Indramat-MKD-Project-Planning-Manual_compressed.pdf#page=63\"\u003eRexroth motor dimensions and type code (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/5247936417051-Indramat-Rexroth-MKD-MKE-Resolver-and-Digital-Board-Test-Procedures\"\u003eMKD feedback assembly reference\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe resolver produces angle-dependent signals from an excitation. The K assembly also tracks multiple revolutions and carries motor identification and alignment data in its feedback electronics. The Rexroth drive reads the feedback through the assigned motor connection. A resolver that produces smooth angle data can still be paired with a failed, incorrect or misprogrammed board. A drive readout with the wrong turn number or a loss of position after power-off also warrants checking the K battery and pickup system under the documented procedure. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26659902744603-Indramat-Digital-Motors-Serial-Encoders-and-Resolvers\"\u003eMitchell digital Indramat interface and memory\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/5247936417051-Indramat-Rexroth-MKD-MKE-Resolver-and-Digital-Board-Test-Procedures\"\u003eMKD K hardware and checks\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse this reference only for the \u003cstrong\u003estandard connector-box X3 in Rexroth figure 12-2\u003c\/strong\u003e. Follow the manufacturer's contact numbers and drawing view. The two brown conductors have different functions. The internal six-pin green resolver plug and the circular connector on other MKD sizes require separate drawings.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Rexroth MKD connector-box X3 motor terminals\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eRexroth MKD connector-box X3 motor terminals\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eX3 position\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDiagram signal\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRexroth cable colour\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1\u003c\/th\u003e\n\u003ctd\u003e0 V\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2\u003c\/th\u003e\n\u003ctd\u003eFS\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3\u003c\/th\u003e\n\u003ctd\u003eS1\u003c\/td\u003e\n\u003ctd\u003eBrown (0.25 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4\u003c\/th\u003e\n\u003ctd\u003eSCL\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e5\u003c\/th\u003e\n\u003ctd\u003eS3\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e6\u003c\/th\u003e\n\u003ctd\u003eSDI\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e7\u003c\/th\u003e\n\u003ctd\u003eS2\u003c\/td\u003e\n\u003ctd\u003eGray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8\u003c\/th\u003e\n\u003ctd\u003eSDO\u003c\/td\u003e\n\u003ctd\u003eViolet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e9\u003c\/th\u003e\n\u003ctd\u003eS4\u003c\/td\u003e\n\u003ctd\u003ePink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e10\u003c\/th\u003e\n\u003ctd\u003eR1\u003c\/td\u003e\n\u003ctd\u003eBrown (0.5 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse the drive-side schematic and Rexroth shield termination before making a cable. Match the internal plug to the board drawing and photograph its orientation before removal. A fitted connector alone does not establish correct orientation. \u003ca href=\"https:\/\/www.magnaproducts.com\/wp-content\/uploads\/2019\/09\/Indramat-MKD-Project-Planning-Manual_compressed.pdf#page=108\"\u003eRexroth figure 12-2 connector box (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/5247936417051-Indramat-Rexroth-MKD-MKE-Resolver-and-Digital-Board-Test-Procedures\"\u003eMitchell internal plug note\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eFor the motor-to-drive connection box arrangement, Rexroth figure 17-13 shows \u003cstrong\u003eIKS4103\u003c\/strong\u003e for the indicated direct path to HDD\/HDS\/DKC**.3 drives, using INK0448 cable. It separately draws intermediate paths. Order only after matching the exact drive, ends, length and topology. The inside-motor green resolver-to-board loom has no verified order code in the public documents used here. Match its housing, contacts and wiring to the original. TI-5924 and TI-5040 are specialist test leads. \u003ca href=\"https:\/\/www.magnaproducts.com\/wp-content\/uploads\/2019\/09\/Indramat-MKD-Project-Planning-Manual_compressed.pdf#page=167\"\u003eRexroth encoder cable selection and figure 17-13 (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/5247936417051-Indramat-Rexroth-MKD-MKE-Resolver-and-Digital-Board-Test-Procedures\"\u003eMitchell test cable references\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore opening the connection box or turning the shaft.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized. Treat the K board backup battery as a separate energy source and preserve turn data before disturbing it.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecord before resetting.\u003c\/strong\u003e From the existing display, capture the drive fault, motor identification, position and whether the alarm is present at boot, after motion or after power loss. Compare the motor plate and controller record.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect externally.\u003c\/strong\u003e Check X3 mating, glands, contamination, pulled contacts, shield clamp and cable routing. Check the driven coupling and load condition under isolation. A slipping coupling or jam can produce a following error with healthy feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the detached cable.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Use the Rexroth diagram to distinguish the two brown conductors and the required shield bonds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck supply and signals by the documented drive procedure.\u003c\/strong\u003e A qualified technician can use an approved breakout installed with power off. Compare the correct circuit to the drive manual under the specified conditions. Use separate bench setups to compare resolver response and board identification, stored alignment and turn data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterpret the split.\u003c\/strong\u003e Good resolver response with bad board reads points to the board path, memory or its power. Good bench data with an installed alarm shifts attention to X3 cable, supply, controller compatibility or a drive-side feedback input. Good feedback with a mechanical following error calls for checking the load, brake and coupling.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThis guide applies to the standard Bosch Rexroth Indramat MKD071B-061 K-option servo and its documented connection box. Confirm the drive, firmware and drive-side feedback wiring before ordering. MDD, MHD, MKE, other MKD sizes and other connector schemes have separate service records. \u003ca href=\"https:\/\/www.magnaproducts.com\/wp-content\/uploads\/2019\/09\/Indramat-MKD-Project-Planning-Manual_compressed.pdf#page=107\"\u003eRexroth connection system (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26659902744603-Indramat-Digital-Motors-Serial-Encoders-and-Resolvers\"\u003eMitchell Indramat family identification\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eThe motor needs its own measured or stored commutation relationship. Marking the original position helps preserve a mechanical reference. Before disassembly, a qualified specialist should record the original verified offset, direction, lockup reference, pole count and motor identity. On replacement, use the matching motor and board procedure to restore approved data only after checking actual resolver alignment. A write requires a compatible revision, verified source data and an independent commissioning check. If the original data are corrupt or missing, have the offset established for this motor and drive. Keep the machine datum and multiturn reference records separate. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/5247936417051-Indramat-Rexroth-MKD-MKE-Resolver-and-Digital-Board-Test-Procedures\"\u003eMitchell read-before-teardown and alignment checks\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26659902744603-Indramat-Digital-Motors-Serial-Encoders-and-Resolvers\"\u003eIndramat commutation and derived data\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.magnaproducts.com\/wp-content\/uploads\/2019\/09\/Indramat-MKD-Project-Planning-Manual_compressed.pdf\"\u003eBosch Rexroth MKD project-planning manual R911272495 (PDF)\u003c\/a\u003e. Manufacturer manual copy. Use chapter 8 for MKD071, chapter 12 for X3 and chapter 17 for encoder cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/5247936417051-Indramat-Rexroth-MKD-MKE-Resolver-and-Digital-Board-Test-Procedures\"\u003eMitchell MKD\/MKE resolver and digital board procedure\u003c\/a\u003e. Explains independent resolver and board testing and the K turn-counter hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26659902744603-Indramat-Digital-Motors-Serial-Encoders-and-Resolvers\"\u003eMitchell Indramat digital feedback training\u003c\/a\u003e. Family identification and motor-specific alignment background.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.boschrexroth.com\/ics\/spc\/?Language=EN\"\u003eBosch Rexroth spare-parts reference\u003c\/a\u003e. Search by the material number for current service or replacement options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118226636965,"sku":"TXG07","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/BoschRexrothIndramatMKD071B-061KServoFeedback.jpg?v=1794145388","url":"https:\/\/www.sparefaber.com\/products\/bosch-rexroth-mkd071b-061-k","provider":"SpareFaber","version":"1.0","type":"link"}