{"product_id":"bosch-rexroth-msk040c-nn-m1-feedback-technical-guide","title":"Bosch Rexroth MSK040C \/ NN \/ M1 Multiturn classic HIPERFACE | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eBosch Rexroth MSK040C \/ NN \/ M1 — Multiturn classic HIPERFACE. Use this guide to identify the fitted feedback, separate connection faults from sensor faults and prepare a supported evaluation. SpareFaber can assess an appropriate UAE site visit, installation\/alignment work or send-in bench evaluation after reviewing the actual labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentify the fitted part\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eSend an enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003carticle class=\"feedback-guide\"\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted part\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"id-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide scope\u003c\/th\u003e\n\u003ctd\u003eBosch Rexroth MSK040C \/ NN \/ M1 — motor feedback application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback identity\u003c\/th\u003e\n\u003ctd\u003eMSK option M1; fitted encoder full label required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMain model \/ application identifier\u003c\/th\u003e\n\u003ctd\u003eMSK040C \/ NN \/ M1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor order scope\u003c\/th\u003e\n\u003ctd\u003eFrame\/cooling\/feedback configuration, not a complete inspected motor order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eMultiturn classic HIPERFACE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting connection\u003c\/th\u003e\n\u003ctd\u003eTI-5093 + TI-5104 only at the matched MSK motor feedback connector; direct HIPERFACE uses its separate map.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eSpecialist testing: connection before conclusion\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-5000JX bench scope\u003c\/th\u003e\n\u003ctd\u003eConditional TI-5000JX scope. MSK040C frame: multiturn HIPERFACE; check retained turns, motor memory and brake-length clearance. Preserve incoming motor memory and stored commutation offset; verify S01 versus K01\/K02 and drive-firmware restrictions before replacement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarting lead \/ fixture\u003c\/th\u003e\n\u003ctd\u003eTI-5093 + TI-5104 only at the matched MSK motor feedback connector; direct HIPERFACE uses its separate map.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfile \/ module\u003c\/th\u003e\n\u003ctd\u003ePreserve incoming motor memory and stored commutation offset; verify S01 versus K01\/K02 and drive-firmware restrictions before replacement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTI-3000JX motor-run scope\u003c\/th\u003e\n\u003ctd\u003eConditional documented MSK motor-run scope. Confirm winding, poles, motor-specific memory offset, power\/brake connector, cooling and amplifier limits; frame size does not establish run capability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe documented test reference is Rexroth Motors — MSK supported family + HIPERFACE\/EnDat; OEM printed pp.97, 113, 131; option M1. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eThe linked manufacturer record documents this configuration. Current production, stock and an approved successor for the complete fitted order still require manufacturer confirmation. A historical manual or downloadable CAD drawing does not prove present availability. Match voltage, mounting, shaft, brake, feedback, connector and motor-data requirements before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications and interface\u003c\/h2\u003e\n\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback technology\u003c\/th\u003e\n\u003ctd\u003eMultiturn classic HIPERFACE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor frame \/ length\u003c\/th\u003e\n\u003ctd\u003eMSK040C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling option\u003c\/th\u003e\n\u003ctd\u003eNN: natural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEncoder option\u003c\/th\u003e\n\u003ctd\u003eM1 — Multiturn classic HIPERFACE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition scope\u003c\/th\u003e\n\u003ctd\u003eMultiturn; evaluate retained revolutions separately from within-turn position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutline drawing\u003c\/th\u003e\n\u003ctd\u003eOEM project planning manual printed p.97; type code p.113; encoder connection p.131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eComplete order required\u003c\/th\u003e\n\u003ctd\u003eWinding, connection orientation, shaft, brake and design suffix are not specified by this guide title.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eService values\u003c\/th\u003e\n\u003ctd\u003eEncoder coupling dimensions, exact pin map and tightening torque require the fitted assembly drawing. No value is inferred from a related motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eClassic HIPERFACE combines serial data with analogue sine\/cosine position tracks. Evaluate both; this scope does not extend to HIPERFACE DSL. A within-turn reading does not verify the multiturn mechanism or stored motor identity.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mounting\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming shaft datum, pilot, bolt pattern, rear clearance, cable exit and retaining arrangement before removal. Use the exact drawing for tolerances and fastening. Do not infer encoder coupling dimensions or tightening torque from the motor flange size. Inspect looseness, bearing play, debris and moisture before disturbing the feedback attachment. The MSK040C outline on printed page 97 controls installation space. Read the length column for this frame and actual feedback\/brake option. The U connector arrangement in the relevant type key allows a 240-degree orientation range; check the fitted order and cable clearance before adjustment.\u003c\/p\u003e\n\u003cp\u003eMSK040C with NN cooling and M1 feedback is a frame\/cooling\/encoder configuration, not a complete motor order. MSK040C frame: multiturn HIPERFACE; check retained turns, motor memory and brake-length clearance. C-length drawing; 4 Nm brake option and 240-degree connector arrangement.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eKeep motor power, protective earth, feedback, temperature sensing and any holding brake as separate circuits. Establish contact numbering, keying, gender and whether the drawing shows the mating face or wire side. Do not infer a pin map from a connector shell. TI-5093 + TI-5104 only at the matched MSK motor feedback connector; direct HIPERFACE uses its separate map. Classic HIPERFACE serial and sine\/cosine paths must both be checked with the matched fixture. Do not transfer a direct-encoder supply assumption to the motor-bulkhead connection.\u003c\/p\u003e\n\u003cp\u003eStarting connection for this guide: TI-5093 + TI-5104 only at the matched MSK motor feedback connector; direct HIPERFACE uses its separate map.. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal loom and machine cables\u003c\/h2\u003e\n\u003cp\u003eRecord the internal encoder-to-motor loom separately from the external machine cable and test fixture. The internal loom part number is not established by the motor model alone. Obtain the assembly drawing and both connector faces. Match cable length, shielding, temperature rating and fixed or flexing duty to the installation; a Mitchell test lead is not an OEM replacement cable.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIsolation and measurement conditions\u003c\/summary\u003e\u003cp\u003eSecure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity\/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"table-scroll\"\u003e\u003ctable class=\"fault-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIdentify before testing\u003c\/th\u003e\n\u003ctd\u003eMSK040C with NN cooling and M1 feedback is a frame\/cooling\/encoder configuration, not a complete motor order. MSK040C frame: multiturn HIPERFACE; check retained turns, motor memory and brake-length clearance. C-length drawing; 4 Nm brake option and 240-degree connector arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent fault with cable movement\u003c\/th\u003e\n\u003ctd\u003eAfter isolation and disconnection at both ends, inspect flex points, pin engagement, contamination and previous repairs. Compare continuity and unintended shorts with the exact diagram, allowing for intentional shield bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo serial data or unstable position\u003c\/th\u003e\n\u003ctd\u003eConfirm the profile, low-voltage supply at the correct boundary and mating-face pin assignment. Compare the test fixture with the actual motor connector; a plausible connector fit does not prove electrical compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback reads but the drive rejects it\u003c\/th\u003e\n\u003ctd\u003eRecord the original alarm and check exact motor identity, stored data requirements, direction, mechanical attachment and the supported signal paths. A reset is not proof of a compatible replacement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReplacement dimensions look close\u003c\/th\u003e\n\u003ctd\u003eCompare the exact model, shaft, pilot, brake, seal, cooling and connector options above with the linked drawing before ordering or removing the original assembly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, reference and memory\u003c\/h2\u003e\n\u003cp\u003ePreserve the original mechanical reference, motor phase convention, direction and readable drive data before disassembly. Use the fitted motor and encoder service procedure for replacement. Communication alone does not prove correct alignment or machine origin. MSK stores motor-specific information and an electronic commutation offset. Preserve the incoming data before supported memory or alignment work; do not write a generic angle. For a SICK S01-to-K01\/K02 replacement, Mitchell identifies a controller-firmware boundary: MPx-V20 or later requires S01. Earlier firmware does not remove the need to match the motor data, mechanical assembly and complete encoder identity.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eMSK040C, natural convection, Multiturn classic HIPERFACE. MSK040C with NN cooling and M1 feedback is a frame\/cooling\/encoder configuration, not a complete motor order. MSK040C frame: multiturn HIPERFACE; check retained turns, motor memory and brake-length clearance. C-length drawing; 4 Nm brake option and 240-degree connector arrangement.\u003c\/p\u003e\n\u003cp\u003eA matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26687041142427-Rexroth-Motors\" target=\"_blank\" rel=\"noopener\"\u003eRexroth Motors\u003c\/a\u003e — MSK supported family + HIPERFACE\/EnDat; OEM printed pp.97, 113, 131; option M1\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4404782999707-Rexroth-MSK-support\" target=\"_blank\" rel=\"noopener\"\u003eRexroth MSK support\u003c\/a\u003e — Named motor family and feedback option; row locator identifies scope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26692268303899-Rexroth-Motors\" target=\"_blank\" rel=\"noopener\"\u003eRexroth Motors\u003c\/a\u003e — Named motor family and feedback option; row locator identifies scope\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.magnaproducts.com\/wp-content\/uploads\/2019\/09\/Indramat-MSK-Project-Planning-Manual_compressed.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBosch Rexroth R911296289, IndraDyn S MSK Project Planning Manual, Edition 06\u003c\/a\u003e — Chapters 5–7: frame drawings, type codes and feedback options; 2006 revision, not a current availability statement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eObtain the complete fitted motor and encoder labels, exact service ID, internal loom, connector mating-face drawing and approved setup. Match the linked OEM document revision; unverified supply, pins, retention fasteners and alignment values remain open.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"questions\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should accompany a MSK040C \/ NN \/ M1 enquiry?\u003c\/summary\u003e\u003cp\u003eSend clear photographs of the motor and feedback labels, every suffix\/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan the listed Mitchell lead be used as a replacement machine cable?\u003c\/summary\u003e\u003cp\u003eThe lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes a successful feedback bench test prove that the motor can be run? \u003c\/summary\u003e\u003cp\u003eConditional documented MSK motor-run scope. Confirm winding, poles, motor-specific memory offset, power\/brake connector, cooling and amplifier limits; frame size does not establish run capability. A complete run assessment also checks motor power, brake, protection and mechanical conditions.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhen does a site visit or send-in evaluation make sense?\u003c\/summary\u003e\u003cp\u003eA site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003csection id=\"service\"\u003e\u003ch2\u003eRequest a scoped service evaluation\u003c\/h2\u003e\n\u003cp\u003eUse the existing \u003ca href=\"#encoder-enquiry\"\u003eencoder enquiry form\u003c\/a\u003e with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation\/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"related\"\u003e\u003ch2\u003eRelated technical guides\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/sparefaber.com\/products\/rexroth-indradyn-s-msk-m1-multiturn-hiperface-feedback\" target=\"_blank\" rel=\"noopener\"\u003eTCG345 — Bosch Rexroth IndraDyn S MSK M1 Multiturn HIPERFACE Feedback\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51153431265445,"sku":"TCG728","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/bosch-rexroth-msk040c-nn-m1-service-guide.jpg?v=1794379276","url":"https:\/\/www.sparefaber.com\/products\/bosch-rexroth-msk040c-nn-m1-feedback-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}