{"product_id":"bosch-rexroth-msk100b-nn-endat-2-1-st-mt-technical-guide","title":"Bosch Rexroth MSK100B \/ NN Heidenhain EnDat 2.1 Singleturn \/ Multiturn Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eBosch Rexroth MSK100B \/ NN\u003c\/strong\u003e with Heidenhain EnDat 2.1 is covered in this technical guide. Use it to identify the fitted assembly, compare the documented feedback branches, preserve incoming alignment and readable data, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentification\u003c\/a\u003e · \u003ca href=\"#testing\"\u003eTesting\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mechanical-fit\"\u003eMechanical fit\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDocuments\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eService enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted motor and feedback\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eIdentification item\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eScoped information\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer \/ grouped base\u003c\/td\u003e\n\u003ctd\u003eBosch Rexroth MSK100B \/ NN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eTCG1765; SpareFaber service-guide reference, not an OEM part number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame \/ family\u003c\/td\u003e\n\u003ctd\u003eMSK100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue M0 \/ stall reference\u003c\/td\u003e\n\u003ctd\u003e28 Nm; match the selected catalogue row, conditions and complete fitted order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling \/ assembly\u003c\/td\u003e\n\u003ctd\u003eNN natural convection; separate fan-cooled and higher-temperature-rise ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor-data source\u003c\/td\u003e\n\u003ctd\u003eMSK100 B p.82; M0_60 28 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical source\u003c\/td\u003e\n\u003ctd\u003eExact MSK100 dimensional sheet and full order; MSK100 type-code chapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoverage boundary\u003c\/td\u003e\n\u003ctd\u003edocumented single-turn and multi-turn options; base identifier omits complete speed\/winding\/shaft\/brake\/factory suffixes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003ePhotograph the complete motor plate, serial, encoder label, feedback connector face and drive nameplate before disturbing the assembly. Record the actual brake, shaft, mounting, cooling, thermal sensor and speed\/winding fields. S2\/M2 is the documented branch grouping used here; it is not a full factory order or an authorization to exchange devices.\u003c\/p\u003e\n\u003cp\u003eKeep optical\/capacitive device branches and their complete order restrictions explicit; no generic donor encoder or memory image is assigned.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"testing\"\u003e\u003ch2\u003eSpecialist feedback testing\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDevice-level test scope:\u003c\/strong\u003e Identify the fitted Heidenhain encoder and its actual protocol before choosing the installed serial selection. Compare serial position\/status and documented exposed analogue channels independently. TI-5101 applies to exposed 1 Vpp channels; it does not replace EnDat serial communication or establish a universal motor-bulkhead lead or memory layout.\u003c\/p\u003e\n\u003cp\u003eRecord the tester hardware, lead\/module, software version, selected feedback type and actual fitted label with the report. First record the incoming fitted-device configuration and relevant position\/signal observations. Preserve supported readable identity and data before any write. A changing count or angle alone does not prove correct mechanical installation, signal quality, commutation sequence or drive configuration.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eTest record\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat the observation establishes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabel and setup match\u003c\/td\u003e\n\u003ctd\u003eThe selected device, electrical interface and supply\/excitation match the identified branch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlow manual movement\u003c\/td\u003e\n\u003ctd\u003eDirection, continuity, cyclic behaviour and the applicable index\/turn transition can be compared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus \/ alarm readback\u003c\/td\u003e\n\u003ctd\u003eDevice-reported status can be separated from cable\/controller symptoms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue levels where present\u003c\/td\u003e\n\u003ctd\u003eCompare exposed A\/B quality independently of serial position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBefore\/after report\u003c\/td\u003e\n\u003ctd\u003eIncoming configuration and each approved service change remain traceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eMotor-run scope:\u003c\/strong\u003e TI-5000JX feedback evaluation and TI-3000JX motor-run approval are separate decisions. Establish full motor parameters, pole count, phase convention, fixture\/load, brake handling and speed\/current limits before a run. A supported feedback protocol does not approve a run profile for this complete motor. No universal minimum firmware or exact motor-bulkhead adapter is asserted here.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eMotor data and singleturn\/multiturn comparison\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eS2 ST\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eM2 MT\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eOptical EnDat 2.1\u003c\/td\u003e\n\u003ctd\u003eOptical EnDat 2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue signal periods\u003c\/td\u003e\n\u003ctd\u003e2,048 per revolution\u003c\/td\u003e\n\u003ctd\u003e2,048 per revolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute turns\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e4,096\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign suffix\u003c\/td\u003e\n\u003ctd\u003eMatch permitted full-order variant\u003c\/td\u003e\n\u003ctd\u003eMatch permitted full-order variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply reference\u003c\/td\u003e\n\u003ctd\u003eOEM 3.6–14 V table; verify actual label\u003c\/td\u003e\n\u003ctd\u003eDo not treat analogue periods as serial position resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe catalogue torque reference for this grouped base is 28 Nm. It is used for identification and priority, not as momentary peak torque or a guaranteed rating for every speed\/winding\/cooling condition. The 28 Nm value is NN M0_60. The higher 100 K-rise or fan-cooled ratings are separate conditions.\u003c\/p\u003e\n\u003cp\u003eDocumented ST and MT options share this interface guide. Keep fitted device identity, resolution, turn range, holder and connector subcases distinct.\u003c\/p\u003e\n\u003cp\u003eKeep optical\/capacitive device branches and their complete order restrictions explicit; no generic donor encoder or memory image is assigned.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mechanical-fit\"\u003e\u003ch2\u003eMechanical fit, cooling and removal reference\u003c\/h2\u003e\n\u003cp\u003eCompare the exact MSK100B \/ NN drawing and full winding, shaft, mounting, brake, cooling and feedback-holder order. Identify fitted connector orientation and cable clearance before removal. Preserve NN natural-cooling and the exact allowed design suffix.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFit item\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRecord and compare\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlange \/ pilot \/ mounting holes\u003c\/td\u003e\n\u003ctd\u003eUse the exact drawing and mounting version, including connector clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft \/ key \/ coupler\u003c\/td\u003e\n\u003ctd\u003eRecord actual dimensions, insertion depth and machine reference before removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoder mounting\u003c\/td\u003e\n\u003ctd\u003eIdentify holder, coupling, fasteners and mechanical reference from the fitted device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake and fan\u003c\/td\u003e\n\u003ctd\u003eIdentify options and added envelope; verify their separate electrical circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeals \/ coolant \/ enclosure\u003c\/td\u003e\n\u003ctd\u003eMatch the actual cooling arrangement and ingress-protection build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eMark the incoming relationship between motor housing, feedback body, shaft and machine reference. Support the assembly without loading the encoder shaft or bearing through an improvised puller. Use the documented removal and assembly method for the fitted device; no unreviewed taper, fastening torque, air gap or insertion force is supplied by this grouped guide.\u003c\/p\u003e\n\u003cp\u003eMechanical drawings to compare: Exact MSK100 dimensional sheet and full order; MSK100 type-code chapter. Connector orientation and holder variants can change practical clearance even where the nominal frame is the same. A similar-looking donor motor does not establish identical shaft, brake or encoder fit.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eTrace the fitted connector using its stated contact-side view. Keep supply\/excitation, signal pairs, protective earth, brake, thermal and motor circuits identified separately.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eCircuit \/ branch\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eIdentification boundary\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnDat\u003c\/td\u003e\n\u003ctd\u003eFitted clock\/data pairs and supply\/return\/sense\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue\u003c\/td\u003e\n\u003ctd\u003eDocumented 2,048-period paths, separate from serial resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eConfirm the full RNNN\/other permitted variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eRead connector drawings in their stated contact-side view and verify numbering, keyway, male\/female contacts and shell position. Check continuity with both ends isolated before applying feedback power. Photograph and label any repaired or custom loom so the test report identifies the actual route used.\u003c\/p\u003e\n\u003cp\u003eKeep motor phase conductors, brake supply, fan supply, protective earth, thermal circuits, encoder supply\/return and signal pairs distinct. Do not infer a pinout from wire colour, a shared connector shell, another manufacturer's motor or an electrically different feedback option. If a diagram caption and an order table disagree, resolve the actual fitted branch before energizing it.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"cables\"\u003e\u003ch2\u003eTest leads, internal loom and machine cable\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eConnection layer\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat must be established\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect encoder plug\u003c\/td\u003e\n\u003ctd\u003eExact device connector and compatible bench lead; not automatically a motor-bulkhead connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor internal loom\u003c\/td\u003e\n\u003ctd\u003eContinuity, shielding, strain relief and any changes made during earlier repairs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor feedback \/ hybrid bulkhead\u003c\/td\u003e\n\u003ctd\u003eCorrect socket, contact view, branch and separate power\/brake\/thermal circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine cable\u003c\/td\u003e\n\u003ctd\u003eBoth endpoint pinouts, length\/routing, drag-chain damage and shield termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive \/ tester end\u003c\/td\u003e\n\u003ctd\u003eCorrect installed selection, supply module and interface-specific lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eA device that reads correctly with a direct plug but fails through the motor can point to the internal loom or bulkhead route. A device that works at the motor but fails through the machine harness requires an endpoint-by-endpoint cable check. Document which layer was bypassed; do not report a complete motor or machine harness as proven from a direct encoder test.\u003c\/p\u003e\n\u003cp\u003eThe analogue and serial paths may fail independently. Preserve differential pair integrity and verify supply at the actual device where the documented sense arrangement permits. Do not bridge sense wires or reassign unused contacts without the fitted device's drawing.\u003c\/p\u003e\n\u003cp\u003eNo complete machine-cable part number or universal lead is assigned to every configuration in this guide. Select or document the cable only after the complete motor\/encoder labels and both connector endpoints are known.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003eDiagnostic symptoms and useful comparisons\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eReported symptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eEvidence to collect before changing parts\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo position \/ no communication\u003c\/td\u003e\n\u003ctd\u003eSupply\/return, selected protocol, device identity and isolated cable continuity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition changes but drive faults remain\u003c\/td\u003e\n\u003ctd\u003eStatus codes, configuration, motor-data interpretation and phase\/alignment relationship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent or noisy behaviour\u003c\/td\u003e\n\u003ctd\u003eConnector contact, strain\/routing, shield integrity and signal quality through each cable layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncorrect direction or scaling\u003c\/td\u003e\n\u003ctd\u003eRecorded device direction, selected protocol\/word format and drive scaling; do not rewrite offsets to hide it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiturn value unexpected\u003c\/td\u003e\n\u003ctd\u003eFitted MT identity, documented turn range and incoming count across a controlled turn boundary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault appeared after removal\u003c\/td\u003e\n\u003ctd\u003eOriginal reference marks, mechanical holder\/shaft relationship, supported offsets and before\/after reports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eCompare one identified path at a time: direct encoder, internal loom, motor bulkhead, then machine cable\/drive. Retain the original symptom, fault codes and setup with each result. An isolated cable fault, an unsupported test selection and a damaged encoder can present a similar initial symptom.\u003c\/p\u003e\n\u003cp\u003eWhere the fitted branch exposes analogue A\/B, inspect those outputs separately from serial position\/status. A successful serial read is not a complete analogue-quality check.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, offsets and memory preservation\u003c\/h2\u003e\n\u003cp\u003eCapture incoming mechanical reference, supported electrical\/commutation angle, offsets, position\/status, identity and readable memory before removal or writes. Save a report that identifies the full motor, encoder, fixture, lead and selected software configuration. Preserve valid incoming data as the reference for any approved repair.\u003c\/p\u003e\n\u003cp\u003eAfter mechanical work, check the fitted encoder's mounting and signal quality before interpreting an angle. A wrong cable\/selection or an unstable mechanical fit can make an otherwise valid offset appear incorrect. Do not copy an angle, memory image or motor profile from another motor merely because its frame or protocol matches.\u003c\/p\u003e\n\u003cp\u003eOnly use memory or electronic-alignment functions that are explicitly supported for the identified encoder and motor application. A generic device-level capability does not prove that every manufacturer's memory layout is understood.\u003c\/p\u003e\n\u003cp\u003eIf the original relationship or data is unavailable, define a motor-specific recovery method from documented motor\/feedback information and the installed test system. This guide does not prescribe a universal lock-up angle, firmware threshold, phase convention or replacement memory file. Record the before\/after evidence and the exact change performed.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eService scope, replacement and availability\u003c\/h2\u003e\n\u003cp\u003eThis is a technical-guide\/service listing for Bosch Rexroth MSK100B \/ NN, not a claim that a complete motor, encoder, brake, fan or cable is held in stock. Parts and service scope follow review of the full fitted labels, connector photos, fault report and required operating conditions.\u003c\/p\u003e\n\u003cp\u003eA replacement decision must compare interface, absolute\/analogue behaviour, supply, mounting, shaft\/holder, connector route, thermal\/brake options, supported motor data and drive compatibility. A motor-base match alone does not establish a drop-in replacement. Catalogue inclusion does not prove current production, exact-order availability, turnaround or certification.\u003c\/p\u003e\n\u003cp\u003eProvide clear label and connector photographs plus the reported symptom and any previous repair changes for a scoped UAE site visit or send-in evaluation. The service quotation can then identify the assessment, repair, alignment or installation work and any parts that require confirmation.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eApplications and practical service enquiries\u003c\/h2\u003e\n\u003cp\u003eThe selected MSK100 frame\/family and 28 Nm catalogue reference place this guide in the identified motor range; they do not rate a new machine duty. Typical enquiries concern feedback faults, connector\/loom repair, motor replacement identification, reinstallation after mechanical work and preservation of existing alignment\/data.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompare the exact motor and feedback branch during a repair intake.\u003c\/li\u003e\n\u003cli\u003eDocument a cable-versus-encoder investigation before replacing an otherwise serviceable assembly.\u003c\/li\u003e\n\u003cli\u003ePrepare an installation or reinstallation visit with complete labels, drive details and machine reference.\u003c\/li\u003e\n\u003cli\u003eAssess an identified replacement against the actual shaft, cooling, brake, connector and data requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRelated interface guides for the same base: \u003ca href=\"\/products\/bosch-rexroth-msk100b-nn-classic-hiperface-st-mt-technical-guide\"\u003eClassic HIPERFACE — TCG1756\u003c\/a\u003e. Each retains its own electrical scope.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest installation, repair or alignment assessment\u003c\/a\u003e and include reference \u003cstrong\u003eTCG1765\u003c\/strong\u003e.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, manuals and evidence\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cmafh.com\/images\/Master%20PDFs\/BRC\/Motors\/MSK\/Rexroth%20MSK%20Project%20Planning%20Manual%20R911296289_10.pdf\"\u003eBosch Rexroth MSK project-planning manual R911296289, PR10\u003c\/a\u003e. MSK100 B p.82; M0_60 28 Nm. Mechanical reference: Exact MSK100 dimensional sheet and full order; MSK100 type-code chapter.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26653326767387-Heidenhain-Serial-Encoders\"\u003eMitchell Heidenhain serial interface reference\u003c\/a\u003e. Use fitted-device support and the actual compatible lead.\u003c\/li\u003e\n\u003cli\u003eRead the selected motor table and matching full type-code\/dimensional chapter. MSK101D\/FN EnDat already has a separate existing guide and is not duplicated in this batch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese references support the scoped family and documented options. The complete fitted order and actual device revision determine the final wiring, envelope, software selection and service method. Keep the source edition\/page, nameplate photos and measured setup with the report so a later technician can reproduce the identification.\u003c\/p\u003e\n\u003cp\u003eThe cover is a branded service illustration with concise headings. It is not an OEM dimensional drawing or proof of the exact motor\/encoder installed in a machine.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"faq\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs this a complete factory motor order?\u003c\/h3\u003e\n\u003cp\u003eNo. Bosch Rexroth MSK100B \/ NN is a guide grouping. Match all winding\/speed, shaft, mounting, cooling, brake, feedback and custom-order fields on the actual plates.\u003c\/p\u003e\n\u003ch3\u003eWhy are singleturn and multiturn on one page?\u003c\/h3\u003e\n\u003cp\u003eThey share the scoped interface. Device labels, resolution, revolution range, mechanical variants and supported setup remain distinguished in the comparison table.\u003c\/p\u003e\n\u003ch3\u003eCan I use another motor's cable or test selection?\u003c\/h3\u003e\n\u003cp\u003eOnly after the actual device, supply, complete endpoint wiring and installed support are established. A shared shell, frame or protocol name is not enough.\u003c\/p\u003e\n\u003ch3\u003eDoes feedback testing prove a motor-run setup?\u003c\/h3\u003e\n\u003cp\u003eNo. Exact motor parameters, fixture\/load, brake and phase\/alignment conventions require their own motor-specific run-test approval.\u003c\/p\u003e\n\u003ch3\u003eCan the original alignment and data be preserved?\u003c\/h3\u003e\n\u003cp\u003eCapture available incoming identity, mechanical reference, supported angles\/offsets and readable data before removal or writes. Recovery after missing data requires a defined motor-specific method.\u003c\/p\u003e\n\u003ch3\u003eHow do I request service?\u003c\/h3\u003e\n\u003cp\u003eSend full motor and encoder labels, connector photographs, drive details, fault symptoms and previous repair changes with TCG1765. Installation, repair, alignment and site\/send-in scope follow identification.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eSend a service enquiry for TCG1765\u003c\/a\u003e.\u003c\/p\u003e\u003c\/section\u003e","brand":"Bosch Rexroth","offers":[{"title":"Default Title","offer_id":51298385985701,"sku":"TCG1765","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/bosch-rexroth-msk100b-nn-endat-2-1-st-mt-technical-guide-cover.jpg?v=1795462020","url":"https:\/\/www.sparefaber.com\/products\/bosch-rexroth-msk100b-nn-endat-2-1-st-mt-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}