{"product_id":"festo-emmt-as-80-m-hs-rsb-endat-singleturn-feedback","title":"Festo EMMT-AS-80-M-HS-RSB Hybrid EnDat Singleturn Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eRead RSB and order number 5255439 on the motor. Festo identifies this exact configuration as ECI 1118 singleturn EnDat 2.2. The hybrid bulkhead and the direct encoder plug require different drawings.\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE on-site fault diagnosis, installation and alignment checks for the documented feedback. Send the fitted labels and alarm details to arrange a visit or a send-in evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Festo EMMT-AS-80-M-HS-RSB Hybrid EnDat Singleturn Feedback technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Read the singleturn EnDat feedback at the encoder. Confirm the fitted device ID and retention of motor data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Verify a safe direct-feedback setup and motor data. Hybrid bulkhead run fixture remains open.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e TI-5668 for the documented direct-encoder connection.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eFesto EMMT-AS-80-M-HS-RSB Hybrid EnDat Singleturn Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEMMT-AS-80-M-HS-RSB · 5255439\u003c\/th\u003e\n\u003ctd\u003eFesto exact order, size 80 medium length, high-speed RSB configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eECI 1118\u003c\/th\u003e\n\u003ctd\u003eFesto lists this fitted rotor-position sensor for 5255439. Read its exact HEIDENHAIN ID for internal replacement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRMB configurations\u003c\/th\u003e\n\u003ctd\u003eOther EMMT-AS orders use multiturn feedback. Read the complete motor order before transferring data or choosing the cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRotor position\u003c\/th\u003e\n\u003ctd\u003e18-bit singleturn, one absolute revolution, EnDat 2.2 on Festo 5255439.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHybrid connection\u003c\/th\u003e\n\u003ctd\u003eM23x1, 15 contacts, motor-out code 80P. Festo lists digital motor-temperature transfer over EnDat 2.2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor frame\u003c\/th\u003e\n\u003ctd\u003eSize 80, five pole pairs on the exact Festo order. Verify mechanical dimensions and flange in the catalogue.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest connection\u003c\/th\u003e\n\u003ctd\u003eMitchell specifies TI-5668 for direct encoder access on the EMMT-AS family.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe encoder provides serial absolute angle and the applicable status over EnDat. Festo also uses the digital path for motor temperature. A defect in the shared hybrid harness can affect several signals without a mechanical encoder failure.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the size-80 M-frame catalogue outline and installed ECI 1118 drawing. Record the rear assembly locating features, sensor seating and any gap reference before disturbing the inductive encoder.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eUse the 80P hybrid connection drawing from Festo for the motor and drive. Use a separate, matching direct-encoder pin map for TI-5668. Confirm the contact view and keep power, feedback and any brake circuits distinct.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eOrder the hybrid motor cable against 5255439 and the connected drive. Identify the internal harness by the fitted ECI connector. The TI-5668 fixture is a direct diagnostic connection.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eUse only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHybrid system faults but direct encoder reads\u003c\/th\u003e\n\u003ctd\u003eInspect the shared cable, bulkhead, drive and cable routing with the 80P drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial reading or temperature data drops out\u003c\/th\u003e\n\u003ctd\u003eVerify the exact EnDat path, connection and configured drive interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault begins after encoder replacement\u003c\/th\u003e\n\u003ctd\u003eReview the sensor installation, original memory and the motor-specific alignment record.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003ePreserve the original Festo memory and measured reference where supported. Verify the complete Festo commissioning procedure and the fitted EnDat service settings before fitting or programming a replacement.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eFesto EMMT-AS size 80, RSB\u003c\/p\u003e\n\u003cp\u003eUse RSB and frame size to choose the right singleturn drawing and plan access behind the hybrid connector.\u003c\/p\u003e\n\u003ch3\u003eRelated SpareFaber guides\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/festo-emmt-as-100-s-hs-rmb-eqi1331-feedback\"\u003eFesto EMMT-AS-100-S-HS-RMB EQI 1331 EnDat 2.2 Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/festo-emms-as-70-m-ls-rs-550118-endat-feedback\"\u003eFesto EMMS-AS-70-M-LS-RS 550118 EnDat22 Motor Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/heidenhain-eci-1118\"\u003eHEIDENHAIN ECI 1118 EnDat Encoder\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/23778408694939-FESTO-EMME-AS-EMMS-AS-and-EMMT-AS-Series\"\u003eFESTO EMME-AS, EMMS-AS and EMMT-AS Series\u003c\/a\u003e. EMMT-AS, size 60–80 encoder options, hybrid connector and TI-5668\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.festo.com\/media\/catalog\/203024_documentation.pdf\"\u003eFesto EMMT-AS motor catalogue\u003c\/a\u003e. Frame outline and ordering options for the exact RSB branch.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/ftp.festo.com\/public\/PNEUMATIC\/SOFTWARE_SERVICE\/DataSheet\/EN_GB\/5255439.pdf\"\u003eFesto 5255439 exact motor data sheet\u003c\/a\u003e. Fitted ECI 1118, 18-bit singleturn EnDat 2.2, hybrid interface and electrical\/mechanical scope.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51131198210213,"sku":"TCG268","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/festo-emmt-as-80-m-hs-rsb-endat-singleturn-feedback-service-guide.jpg?v=1794277506","url":"https:\/\/www.sparefaber.com\/products\/festo-emmt-as-80-m-hs-rsb-endat-singleturn-feedback","provider":"SpareFaber","version":"1.0","type":"link"}