{"product_id":"festo_187846","title":"Festo CPV14-M1H-2OLS-2GLS-1\/8 187846 Solenoid valve 2x2\/2-way, Open\/closed | Electrical","description":"\u003ch1 class=\"article-summary-headline--cBKWo\"\u003eSolenoid valve\u003cspan class=\"article-summary-order-code--wmt4p\"\u003eCPV14-M1H-2OLS-2GLS-1\/8\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cdiv class=\"article-summary-grid--FZJjK\"\u003e\n\u003cdiv class=\"article-summary-information--kyfm4\"\u003e\n\u003cp class=\"article-summary-code--AenZh\"\u003e187846\u003c\/p\u003e\n\u003cdiv class=\"article-summary-code-details--NOcRN\"\u003e\n\u003cdiv class=\"gtin-container--WDjuD\"\u003e\n\u003cp class=\"gtin--fyeGm\"\u003eGTIN:\u003cspan\u003e \u003c\/span\u003e40525681482\u003c\/p\u003e\n\u003cdiv class=\"article-summary-top-feature-row-container--jHMR0\"\u003e\n\u003cdiv class=\"article-summary-top-feature-name--bsWXW\" title=\"Valve function\"\u003eValve function = 2x2\/2-way, open\/closed, monostable\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-row-container--jHMR0\"\u003e\n\u003cdiv class=\"article-summary-top-feature-name--bsWXW\" title=\"Standard nominal flow rate (standardised to DIN 1343)\"\u003eStandard nominal flow rate (standardised to DIN 1343) = 800 l\/min\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-row-container--jHMR0\"\u003e\n\u003cdiv class=\"article-summary-top-feature-name--bsWXW\" title=\"Pneumatic connection, port 1\"\u003ePneumatic connection, port 1 = Common line\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-row-container--jHMR0\"\u003e\n\u003cdiv class=\"article-summary-top-feature-name--bsWXW\" title=\"Type of actuation\"\u003eType of actuation = Electrical\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-value--aDlhX\" title=\"Electrical\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"article-summary-top-feature-value--aDlhX\" title=\"Electrical\"\u003e\n\u003ch2 class=\"technical-data-header--_TG3G\"\u003eTechnical Data Solenoid valve CPV14-M1H-2OLS-2GLS-1\/8\u003c\/h2\u003e\n\u003cul class=\"technical-data-table--V_IjZ\"\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eValve function\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e2x2\/2-way, open\/closed, monostable\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eType of actuation\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eElectrical\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eValve size\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e14 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eStandard nominal flow rate (standardised to DIN 1343)\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e800 l\/min\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003epneumatic working port\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eG1\/8\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eOperating voltage\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e24 V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eOperating pressure\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e-0.09 MPa ... 1 MPa\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eOperating pressure\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e-0.9 bar ... 10 bar\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eDesign\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003ePiston gate valve\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eType of reset\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003ePneumatic spring\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eDegree of protection\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eIP65\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eNominal size\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e6 mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eExhaust-air function\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eCannot be throttled\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eSealing principle\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eSoft\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eMounting position\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eAny\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eManual override\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eDetenting Non-detenting\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eType of piloting\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003ePiloted\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePilot air supply\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eExternal Internal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eFlow direction\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eNon-reversible\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eSymbol\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e00991802\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003elap\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eOverlap\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePilot pressure\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0.3 MPa ... 0.8 MPa\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePilot pressure\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e3 bar ... 8 bar\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eb value\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0.37\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eC value\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e3.2 l\/sbar\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eSwitching time off\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e16 ms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eSwitching time on\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e13 ms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eDuty cycle\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e100% in conjunction with holding current reduction\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eElectrical power consumption\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e0.65 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eMax. positive test pulse with 0 signal\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e1400 µs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eMax. negative test pulse with 1 signal\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e400 µs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eOperating medium\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eCompressed air to ISO 8573-1:2010 [7:4:4]\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eNote on operating and pilot medium\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eLubricated operation possible (in which case lubricated operation will always be required)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eVibration resistance\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eShock resistance\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eShock test with severity level 2 to FN 942017-5 and EN 60068-2-27\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eCorrosion resistance class CRC\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e2 - Moderate corrosion stress\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eLABS (PWIS) conformity\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eVDMA24364-B1\/B2-L\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eStorage temperature\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e-20 °C ... 40 °C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eMedia temperature\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e-5 °C ... 50 °C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eAmbient temperature\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e-5 °C ... 50 °C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eProduct weight\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003e120 g\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eType of mounting\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eWith through-hole\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePilot air port 12\/14\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eCommon line\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePilot exhaust port 82\/84\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eCommon line\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePneumatic connection, port 1\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eCommon line\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePneumatic connection, port 11\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eCommon line\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePneumatic connection, port 2\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eG1\/8\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePneumatic connection 3\/5 combined\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eCommon line\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003ePneumatic connection, port 4\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eG1\/8\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eNote on materials\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eRoHS compliant\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"technical-data-table-row--wfQ8I\"\u003e\n\u003cspan class=\"technical-data-property--KQV42\"\u003eMaterial seals\u003c\/span\u003e\u003cspan class=\"technical-data-value--f8MJl\"\u003eHNBR NBR\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"FESTO","offers":[{"title":"Default Title","offer_id":48280654774437,"sku":"CPR791","price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/FestoCPV14-M1H-2OLS-2GLS-18187846Solenoidvalve_4.jpg?v=1789304471","url":"https:\/\/www.sparefaber.com\/products\/festo_187846","provider":"SpareFaber","version":"1.0","type":"link"}