{"product_id":"georgii-kobold-ksy-5616-30-d-rg-feedback-service-guide","title":"Georgii Kobold KSY 5616.30 D \/ RG HIPERFACE ST Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eGeorgii Kobold KSY 5616.30 D \/ RG\u003c\/strong\u003e — HIPERFACE ST. This guide helps identify the fitted feedback, distinguish a cable or setup fault and prepare a scoped repair, installation or alignment assessment. SpareFaber accepts UAE site-service and send-in evaluation enquiries after reviewing the motor\/feedback labels and fault history.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#identify\"\u003eIdentification\u003c\/a\u003e · \u003ca href=\"#testing\"\u003eTesting scope\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDrawings and manuals\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eService enquiry\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eIdentify the fitted configuration\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eItem\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer \/ application\u003c\/td\u003e\n\u003ctd\u003eGeorgii Kobold KSY 5616.30 D \/ RG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback\u003c\/td\u003e\n\u003ctd\u003eHIPERFACE ST — SRS 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentifier scope\u003c\/td\u003e\n\u003ctd\u003eBase motor + feedback selection; remaining nameplate suffixes are not specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor mounting\u003c\/td\u003e\n\u003ctd\u003eØ165 PCD \/ Ø130 pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraked representative\u003c\/td\u003e\n\u003ctd\u003eKSY 5616.30 D \/ MD \/ RG \/ 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHolding brake\u003c\/td\u003e\n\u003ctd\u003eMD; 36 Nm; 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpareFaber service reference\u003c\/td\u003e\n\u003ctd\u003eTCG1403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe service reference is not an OEM part number. Verify the complete fitted labels and connector revision before selecting a replacement or test connection.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"testing\"\u003e\u003ch2\u003eSpecialist feedback testing\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX:\u003c\/strong\u003e identified SRS50 \/ SRM50 classic HIPERFACE feedback. Evaluate serial position and analogue signals; retain incoming alignment\/memory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting connection:\u003c\/strong\u003e TI-5069 direct-to-encoder, 8-pin Berg; motor feedback connector is separate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModule \/ software:\u003c\/strong\u003e TI-5104 required. Match actual SRS\/SRM and software selection; minimum firmware not specified in cited article.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor-run scope:\u003c\/strong\u003e TI-3000JX not established for each complete order. Family power-lead references do not prove connector fit or a released run profile.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eSignals and specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented value \/ limit\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM feedback code\u003c\/td\u003e\n\u003ctd\u003eRG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented fitted encoder\u003c\/td\u003e\n\u003ctd\u003eSRS 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eHIPERFACE ST; serial position plus analogue sine\/cosine channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial position per revolution\u003c\/td\u003e\n\u003ctd\u003e15 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue signal periods per revolution\u003c\/td\u003e\n\u003ctd\u003e1024; this is not a drive-scaled position count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiturn range\u003c\/td\u003e\n\u003ctd\u003eSingle-turn; no multiturn counter is claimed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback supply in KSY-D pin table\u003c\/td\u003e\n\u003ctd\u003e+8 V at pin 2; GND pin 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor voltage example\u003c\/td\u003e\n\u003ctd\u003e400 V rated motor build; separate from feedback and brake supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake\u003c\/td\u003e\n\u003ctd\u003eMD; 36 Nm; 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoder + brake dimension k\u003c\/td\u003e\n\u003ctd\u003emaximum 382 mm; use the exact drawing and any special suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eSignal periods, serial position bits, turn range and drive-scaled counts describe different quantities. Use the exact encoder option and controller configuration when comparing readings.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"mechanical-fit\"\u003e\u003ch2\u003eMechanical fit and retention\u003c\/h2\u003e\n\u003cp\u003eThe KSY 5616.30 D is in the KSY 56.. group. The catalogue identifies Ø165 PCD \/ Ø130 pilot and an encoder-plus-brake dimension k of maximum 382 mm. These measurements describe the motor mounting and housing, not the encoder shaft or bore. Compare the actual motor drawing and machine coupling before assessing interchangeability.\u003c\/p\u003e\n\u003cp\u003eRead the encoder label and the motor’s complete special-build suffix before removing the rear assembly. The catalogue supports this family\/option combination; it does not identify every internal coupling, retention screw torque or machine harness. Photograph the mounting and incoming mechanical reference. Do not infer an encoder air gap or tightening torque from a similar KSY motor.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector boundaries\u003c\/h2\u003e\n\u003cp\u003eThe 12-contact motor feedback connector is shown in the KSY-D catalogue on PDF page 9. The table below follows that OEM signal assignment. Use the drawing to confirm connector view, pin orientation and keying; it is not a tester or drive-end wiring table.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eMotor feedback contact\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eOEM signal\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 \/ 6\u003c\/td\u003e\n\u003ctd\u003eDATA− \/ DATA+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eVCC (+8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 \/ 8\u003c\/td\u003e\n\u003ctd\u003eSIN \/ REFSIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 \/ 9\u003c\/td\u003e\n\u003ctd\u003eCOS \/ REFCOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eGND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3, 10, 11, 12\u003c\/td\u003e\n\u003ctd\u003eNot connected in this OEM table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003ePower, brake and thermal contacts are on a different connector. KSY 76.. uses different power-contact markings and contact sizes from KSY 16..–66... Match the correct column of the OEM diagram; never treat similarly shaped connectors as interchangeable.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"cables\"\u003e\u003ch2\u003eInternal, machine and test cables\u003c\/h2\u003e\n\u003cp\u003eTI-5069 direct-to-encoder, 8-pin Berg; motor feedback connector is separate.\u003c\/p\u003e\n\u003cp\u003eThe direct-to-encoder lead connects inside the feedback assembly. It is not the machine cable and is not a mating lead for the motor’s external feedback connector. Confirm the internal connector before connection. No verified OEM internal loom or complete machine cable number is established for this exact special build; record both-end connector photos, labels and length to identify it.\u003c\/p\u003e\n\u003cp\u003eKobold’s Mitchell family entry lists power leads TI-3048 and TI-3029. Select neither solely from this page: the exact motor power connector and tester limits must match.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003ePractical fault checks\u003c\/h2\u003e\n\u003cp\u003eFollow the site isolation procedure before physical checks: secure the driven load, lock out relevant energy sources, observe the drive discharge time and have a qualified technician verify isolation. Disconnect both cable ends before continuity or short testing and account for intentional shield bonds. Powered measurements, rotation, brake release and alignment require the applicable specialist procedure.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObserved symptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eUseful next check\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo serial position\u003c\/td\u003e\n\u003ctd\u003eConfirm the actual feedback code, the documented supply\/sense arrangement and connector contact condition. Isolate the external cable from the encoder before blaming the feedback.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial position reads, analogue quality is poor\u003c\/td\u003e\n\u003ctd\u003eCheck the correct analogue channel pairs and selected period count; investigate cable damage, contamination and connector seating using the approved signal test.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWrong direction or positioning after replacement\u003c\/td\u003e\n\u003ctd\u003eCompare full encoder option, drive scale, direction and motor alignment; do not solve a configuration mismatch by copying an offset from another motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault follows cable movement\u003c\/td\u003e\n\u003ctd\u003eWith power isolated, inspect cable strain, pin retention, contamination and both-end continuity. Verify shield handling against the exact machine drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment, offsets and memory\u003c\/h2\u003e\n\u003cp\u003eRecord the motor’s full label, feedback label, incoming position, phase convention, direction and any stored offset or memory before disturbing the encoder. A successful position read does not prove correct motor commutation alignment. No numerical alignment angle or transferable memory image is established here for the complete motor order.\u003c\/p\u003e\n\u003cp\u003eIf the encoder is replaced or the mechanical reference is lost, obtain the motor-specific alignment method and confirm hardware\/data compatibility before an offset or memory write. Preserve the original data and compare the completed motor assembly with the approved run procedure.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and replacement status\u003c\/h2\u003e\n\u003cp\u003eThe linked KSY-D catalogue documents this historical configuration. It does not establish current stock, continued manufacture of every suffix or a drop-in successor. Confirm supply status and revision against the full fitted labels before a replacement recommendation.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor applications and related guides\u003c\/h2\u003e\n\u003cp\u003eRG identifies SRS50 single-turn; RH identifies SRM50 multiturn. Both are classic HIPERFACE with 1024 analogue periods per revolution. They are different from RS\/RQ SKS36\/SKM36 options and from HIPERFACE DSL.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.sparefaber.com\/products\/georgii-kobold-ksy-d-rg-rh-hiperface-feedback-technical-guide\" target=\"_blank\" rel=\"noopener\"\u003eGeorgii Kobold KSY-D RG \/ RH HIPERFACE Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.sparefaber.com\/products\/georgii-kobold-ksy-d-ecn-1313-re-re2-endat-feedback\" target=\"_blank\" rel=\"noopener\"\u003eGeorgii Kobold KSY-D HEIDENHAIN ECN 1313 EnDat Feedback\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.sparefaber.com\/products\/georgii-kobold-ksy-d-rd-rd-2-endat-feedback-technical-guide\" target=\"_blank\" rel=\"noopener\"\u003eGeorgii Kobold KSY-D RD \/ RD-2 EnDat EnDat optical multiturn\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings and primary documents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.georgiikobold.de\/fileadmin\/medien\/Motoren_PDF\/ksyd_221132_090316_01.pdf\" target=\"_blank\" rel=\"noopener\"\u003eGeorgii Kobold KSY-D catalogue\u003c\/a\u003e — PDF pp. 5–9, 20–25.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/41443030327195-Georgii-Kobold-Motors\" target=\"_blank\" rel=\"noopener\"\u003eMitchell: Georgii Kobold Motors\u003c\/a\u003e — KSY-D row; KSY-D Encoder Systems attachment; KSY-D Connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/bobcat.mitchell-electronics.com\/parts\/271\" target=\"_blank\" rel=\"noopener\"\u003eMitchell TI-5069\u003c\/a\u003e — Part summary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication evidence:\u003c\/strong\u003e K1 pp.5–9,20–21; encoder + brake k max 382 mm. K2: KSY-D row; Encoder Systems attachment, RG row and KSY 56.. fit row.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"faq\"\u003e\u003ch2\u003eFAQ and service enquiry\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eIs RG interchangeable with another KSY feedback option?\u003c\/summary\u003e\u003cp\u003eRG identifies SRS50 single-turn; RH identifies SRM50 multiturn. Both are classic HIPERFACE with 1024 analogue periods per revolution. They are different from RS\/RQ SKS36\/SKM36 options and from HIPERFACE DSL. Verify mounting, wiring, drive support and alignment for the actual motor before substitution.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eDoes the brake create a different feedback guide?\u003c\/summary\u003e\u003cp\u003eNo. The braked representative identifies a useful documented build; brake\/no-brake and winding-only differences are not separate coverage. Brake wiring and release requirements still matter during service.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat should I send with a service enquiry?\u003c\/summary\u003e\u003cp\u003eProvide the complete motor and feedback labels, drive model, connector photos, alarm text, fault timing and previous repair\/replacement history. Include cable labels and any OEM installation drawing. This lets SpareFaber distinguish a site investigation from a send-in feedback or motor assessment.\u003c\/p\u003e\u003c\/details\u003e\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or send-in evaluation\u003c\/a\u003e. Scope, parts and turnaround are confirmed after the fitted configuration and fault are reviewed.\u003c\/p\u003e\u003c\/section\u003e","brand":"Georgii Kobold","offers":[{"title":"Default Title","offer_id":51274025205925,"sku":"TCG1403","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/georgii-kobold-ksy-5616-30-d-rg-feedback-service-guide.png?v=1795333161","url":"https:\/\/www.sparefaber.com\/products\/georgii-kobold-ksy-5616-30-d-rg-feedback-service-guide","provider":"SpareFaber","version":"1.0","type":"link"}