{"product_id":"heidenhain-eci-1119-1164809-05","title":"HEIDENHAIN ECI 1119 1164809-05 EnDat Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for ECI 1119 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"HEIDENHAIN ECI 1119 1164809-05 EnDat Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse a manufacturer-supported EnDat\/ATS setup for identity, diagnostics and mounting quality. The exact 1164809-05 Mitchell fixture, firmware and TI-5000JX profile need confirmation. A TI-3000JX motor run requires a separate exact motor and setup check.\u003c\/p\u003e\n\u003ch2\u003eHEIDENHAIN ECI 1119 1164809-05 EnDat Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003e1164809-05\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1164809-05\u003c\/th\u003e\n\u003ctd\u003e82A Ø6 mm blind hollow shaft, axial clamping.\u003c\/td\u003e\n\u003ctd\u003eECI 1119 single-turn EnDat22.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1164809-55\u003c\/th\u003e\n\u003ctd\u003e82A shaft. Check ID footnote and ordering revision.\u003c\/td\u003e\n\u003ctd\u003eECI 1119 single-turn alternative ID. Confirm safety applicability and configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1164811-05 \/ 1164811-55\u003c\/th\u003e\n\u003ctd\u003e82A variants of the EQI 1131 model.\u003c\/td\u003e\n\u003ctd\u003eMultiturn position. Check motor and drive suitability independently.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for 1164809-05\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for 1164809-05\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition per turn\u003c\/th\u003e\n\u003ctd\u003e524,288 positions (19 bits) for this single-turn ECI 1119.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eEnDat 2.2 with EnDat22 ordering designation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply at encoder\u003c\/th\u003e\n\u003ctd\u003e3.6 to 14 V DC per product information 1359122.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit\u003c\/th\u003e\n\u003ctd\u003e82A blind Ø6 mm bore, axial clamping. Nominal 2 mm mounting clearance for the ATS mounting check.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003e15-pin PCB including a separate external temperature sensor path.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.EN\/hlr-system\/1359122_00_B_02_ECI_1119_EQI_1131FS_70G_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the 82A mating drawing to check the motor journal, locating face and axial clamp. The measured clearance is a mounting check and belongs to the illustrated stack-up. Measure where the drawing shows it and confirm with the ATS mounting function when the approved setup is available.\u003c\/p\u003e\n\u003cp\u003eInspect the locating surfaces and fastening points on the isolated assembly. A small axial shift or tilt changes the scanning gap. Use the OEM instructions for clamping and the permitted assembly tolerances, especially in a safety-related installation.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe drive clocks each EnDat transaction and reads absolute position and diagnostic data from the encoder. ECI 1119 reports position within one turn. The EQI version adds turn information. A drive can read the ID yet still report position quality or fit errors, so inspect the diagnostics alongside the mechanical mounting check.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the HEIDENHAIN connector illustration to orient the plug. Read the complement markings from that illustration and table. An M12 bulkhead has different numbering.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"15-pin PCB groups from document 1359122\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003e15-pin PCB groups from document 1359122\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eContact or group\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e13 \/ 11\u003c\/th\u003e\n\u003ctd\u003eUP \/ 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e14 \/ 12\u003c\/th\u003e\n\u003ctd\u003eSense UP \/ sense 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e7 and 8\u003c\/th\u003e\n\u003ctd\u003eDATA pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e9 and 10\u003c\/th\u003e\n\u003ctd\u003eCLOCK pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e5 \/ 6\u003c\/th\u003e\n\u003ctd\u003eExternal sensor T+ \/ T−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe official product information shows both the encoder-side PCB and the eight-pin M12 flange connection. Use those as distinct drawing views. Look up the exact assembly in the HEIDENHAIN cable catalogue or the motor OEM parts list using the actual connector, lead length and sensor option. The motor-specific loom number remains open.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo EnDat reply\u003c\/th\u003e\n\u003ctd\u003eCheck the supply under load and clock\/data continuity in the isolated harness. Check connector viewing side and drive feedback setting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent quality error over the same part of a turn\u003c\/th\u003e\n\u003ctd\u003eInspect the mating journal and locating face. Compare clearance and ATS mounting values.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition wraps at a turn after a replacement\u003c\/th\u003e\n\u003ctd\u003eConfirm the single-turn ECI versus multiturn EQI requirement and machine referencing method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThis is motor-integrated feedback. Pair the exact ECI label with the motor order and drive EnDat22 input. A related ECI or EQI in a motor with a similar housing can have a different shaft, coupling or position format.\u003c\/p\u003e\n\u003cp\u003eCheck the separate preceding-generation model by its ID. \u003ca href=\"\/products\/heidenhain-eci-1118\"\u003eECI 1118 technical guide\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSet and verify the mechanical fit first. Follow the motor OEM to record and restore any approved commutation or machine-reference data. Use HEIDENHAIN diagnostic functions for mounting quality and the drive commissioning procedure for the installed axis. Safety-related feedback replacement requires the machine’s approved validation.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.EN\/hlr-system\/1359122_00_B_02_ECI_1119_EQI_1131FS_70G_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e. HEIDENHAIN 1359122-00-B-02. Technical table, 82A mounting drawing and PCB\/M12 pin layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/fileadmin\/pdf\/en\/01_Products\/Prospekte\/PR_Cables_and_Connectors_ID1206103_en.pdf\"\u003eHEIDENHAIN cables and connectors\u003c\/a\u003e. Use the exact encoder and motor outlet to choose a mating loom.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51125752594597,"sku":"TCG128","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/heidenhain-eci-1119-1164809-05-service-guide.jpg?v=1794215474","url":"https:\/\/www.sparefaber.com\/products\/heidenhain-eci-1119-1164809-05","provider":"SpareFaber","version":"1.0","type":"link"}