{"product_id":"heidenhain-lc-415-689676-17","title":"HEIDENHAIN LC 415 EnDat Linear Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for LC 415 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"HEIDENHAIN LC 415 EnDat Linear Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eRead the CNC encoder diagnostics first. A bench evaluation needs an EnDat22 reader with the documented 14-pin cable and a suitable fixture for relative travel. Verify reported position, communication errors and consistency across travel. Confirm exact Mitchell profile and cable support before using the \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/sections\/26370850277403-TI-5000JX-Training-Manual\"\u003eMitchell equipment\u003c\/a\u003e on this scale.\u003c\/p\u003e\n\u003ch2\u003eHEIDENHAIN LC 415 EnDat Linear Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003e689676-17\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e689676-17\u003c\/th\u003e\n\u003ctd\u003e920 mm measuring length, 1,058 mm overall by the catalogue formula. 12A end block and mounting spar.\u003c\/td\u003e\n\u003ctd\u003eEnDat22, male 14-pin flange socket, 3.6–14 V DC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e689676-18\u003c\/th\u003e\n\u003ctd\u003e870 mm measuring length, 1,008 mm overall. Same end-block family.\u003c\/td\u003e\n\u003ctd\u003eSame interface designation. Shorter usable measuring length.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e689676-02\u003c\/th\u003e\n\u003ctd\u003e120 mm measuring length, 258 mm overall. Same end-block family.\u003c\/td\u003e\n\u003ctd\u003eSame interface designation. Verify actual machine stroke before sourcing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for 689676-17\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for 689676-17\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring length \/ housing length\u003c\/th\u003e\n\u003ctd\u003e920 mm \/ 920 + 138 = 1,058 mm. Allow separate clearance for the connector and cable bend.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy grade \/ measuring step\u003c\/th\u003e\n\u003ctd\u003e±5 µm \/ 10 nm. Resolution describes the reported step and accuracy describes the stated position error.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGrating \/ speed\u003c\/th\u003e\n\u003ctd\u003e20 µm \/ up to 3 m\/s for this ID.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003e3.6–14 V DC at the scale, male 14-pin flange socket. EnDat 2.2 absolute binary position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.DE\/hlr-system\/1185025-01-b-01.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eStart with drawing 1185025-01 for the LC 4x5\/4x6 mounting family, then select the 12A arrangement in the assembly instructions. Fix the spar and scale to the specified stationary surface and the scanning unit to the translating member. Compare the machine's full travel with the usable measuring length and the permissible position of the scanning unit at both ends.\u003c\/p\u003e\n\u003cp\u003eCheck mounting straightness, clearance for the cable and the condition of the sealing lips on an isolated axis. Use the assembly instruction to set scanning unit position and tightening. Keep the transport or setup fixture until the instructions call for removing it.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe CNC requests an absolute position over EnDat 2.2 using a synchronous clock and bidirectional data. The device reports position along its glass scale. This EnDat22 build omits incremental analog channels. A data fault and an implausible position are different observations and lead to different checks.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThe exact-ID record confirms a male 14-pin flange socket and 3.6–14 V DC. Obtain the HEIDENHAIN connection drawing for the actual scale-to-control cable and verify the mating face and numbered contacts at each end. The mating-dimensions PDF is a mechanical drawing. Connector contact numbering and supply\/sense connections require the corresponding electrical drawing.\u003c\/p\u003e\n\u003cp\u003eFor a loaded voltage check, the qualified technician uses the approved breakout and the documented supply and return at the encoder. Record the voltage during the alarm if the machine's safe diagnostic mode permits it.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThis is an external CNC axis scale. Match the 14-pin encoder socket, control connector, cable length, motion rating and shielding. The OEM machine cable or HEIDENHAIN cable order code is needed before specifying a replacement. A mechanically fitting plug can carry a different electrical assignment.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo EnDat device detected\u003c\/th\u003e\n\u003ctd\u003eCheck the CNC's configured interface, the exact cable, supply at the scale and documented data and clock paths.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault repeats at one axis location\u003c\/th\u003e\n\u003ctd\u003eUnder safe access inspect scale mounting, contamination at the seals and cable flex at that position. Separate a fixed-position optical fault from a cable carrier bend.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition changes smoothly but is offset\u003c\/th\u003e\n\u003ctd\u003eCheck axis preset, direction and the machine datum using a certified reference before adjusting compensation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse on a CNC or other linear axis with a compatible EnDat receiver. Verify axis input type, interpolation or scaling configuration and controller diagnostic support in the machine manual.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eAlign the scale and scanning unit mechanically, then restore the machine datum and any verified axis compensation. LC 415 reports linear position. Motor commutation belongs to the motor's own feedback system. Save the control's axis settings before replacement and validate reference and limits under the OEM commissioning procedure.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/product.heidenhain.de\/JPBC\/image\/HWP.DE\/hlr-system\/1185025-01-b-01.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/sealed-linear-encoders\/689676-17\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/sealed-linear-encoders\/689676-18\"\u003eAlternate length 689676-18\u003c\/a\u003e. Exact manufacturer record.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/sealed-linear-encoders\/689676-02\"\u003eAlternate length 689676-02\u003c\/a\u003e. Exact manufacturer record.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/product-details\/sealed-linear-encoders\/689676-17#\"\u003eMounting instructions via Downloads \/ CAD \/ Mounting\u003c\/a\u003e. Select LC 415 \/ 485 \/ 495, end block 12A, document 1469030. The checked direct link redirected to a maintenance notice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118416822437,"sku":"TCG58","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/HEIDENHAINLC415EnDatLinearEncoder.jpg?v=1794142730","url":"https:\/\/www.sparefaber.com\/products\/heidenhain-lc-415-689676-17","provider":"SpareFaber","version":"1.0","type":"link"}