{"product_id":"heidenhain-ls-403-c","title":"HEIDENHAIN LS 403 C Current-Output Linear Encoder | Technical Guide \u0026 Service","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy CNC axis moves but fails to reference?\u003c\/strong\u003e SpareFaber can check the LS 403 C scale alignment, seals, cable and the control's current-input path at your UAE site. A bench check can isolate the scanning head signal from a cable or downstream interpolation fault.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"HEIDENHAIN LS 403 C Current-Output Linear Encoder technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the complete HEIDENHAIN ID and ML, installed reader or converter model, machine and axis, alarm and where it occurs along the travel. Include photos of the end blocks, connector, label and any mounting spar. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse a compatible current-signal receiver or the manufacturer's specified test interface and loading. Compare the two scanning signals and reference track at the scale and control side. A qualified specialist can check if a dropout repeats at a physical position and whether the receiver decodes the C reference pattern. Exact Mitchell TI-5000JX and TI-3000JX support for this linear scale was not verified. \u003ca href=\"https:\/\/stanki-used.com.ua\/image\/PASSPORT\/CNC\/LS-403_LS-403C.pdf\"\u003eHEIDENHAIN electrical data and follow-up electronics (PDF copy)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eHEIDENHAIN LS 403 C Current-Output Linear Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eRecord the full \u003cstrong\u003eLS 403 C\u003c\/strong\u003e name, the ID and the measuring length (ML) printed on the label. ML is the usable measuring length, distinct from overall scale length. C specifies distance-coded reference marks. The following exact ID examples come from supplier catalogue records and the fitting and signal descriptions come from HEIDENHAIN's original manual.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"LS 403 C ID, travel and connector examples\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eLS 403 C ID, travel and connector examples\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eNameplate \/ ID\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeasuring length and reference\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eTermination\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLS 403 C · 233191-22\u003c\/th\u003e\n\u003ctd\u003eML 470 mm, distance-coded\u003c\/td\u003e\n\u003ctd\u003e02S09 male 9-pin factory connector, 3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLS 403 C · 233191-50\u003c\/th\u003e\n\u003ctd\u003eML 670 mm, distance-coded\u003c\/td\u003e\n\u003ctd\u003e34S09 male 9-pin flange socket on mounting block, 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLS 403 (without C)\u003c\/th\u003e\n\u003ctd\u003eFixed reference mark arrangement. Check the exact length and edition drawing.\u003c\/td\u003e\n\u003ctd\u003eOther terminations exist. Read the actual connector and ID.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/shop.allmendinger.eu\/en\/manufacturer\/heidenhain\/linar-measurement-systems?p=25\"\u003eSupplier record for 233191-22\u003c\/a\u003e · \u003ca href=\"https:\/\/shop.allmendinger.eu\/en\/manufacturer\/heidenhain\/linar-measurement-systems?p=12\"\u003eSupplier record for 233191-50\u003c\/a\u003e · \u003ca href=\"https:\/\/www.fbmsrl.com\/wp-content\/uploads\/2016\/09\/Istruzioni-di-montaggio-LS-403-LS-403C.pdf\"\u003eHEIDENHAIN reference-mark distinction (PDF copy)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThis is an installed-base legacy scale. The original HEIDENHAIN mounting manual and older machine manuals document it. Check current factory repair, successor and stock by exact ID. The modern LS 400 family's name alone is insufficient for replacement. \u003ca href=\"https:\/\/stanki-used.com.ua\/image\/PASSPORT\/CNC\/LS-403_LS-403C.pdf\"\u003eOriginal HEIDENHAIN mounting documentation (PDF copy)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.heidenhain.com\/products\/encoders\/signal-converters\/adaptation-to-interfaces\"\u003eHEIDENHAIN interface converters\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"LS 403 C values from the cited HEIDENHAIN manual\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eLS 403 C values from the cited HEIDENHAIN manual\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue \/ applicability\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd\u003eSealed optical incremental scale, 20 µm glass graduation period. Distance-coded reference marks for the C type.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e5 V ±5% and 120 mA in the full mounting manual for its described lamp-based assembly. Verify the unit's edition and installed documentation before testing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003eSinusoidal current class 11 µApp. The cited full manual gives 7–16 µApp per incremental track at its specified 1 kΩ load, and 2–8 µA useful reference component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTravel speed\u003c\/th\u003e\n\u003ctd\u003eUp to 48 m\/min in the HEIDENHAIN manual, subject to the downstream electronics and actual installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP53 when fitted per instructions. The full manual specifies IP64 with the documented air purge.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement length and connection\u003c\/th\u003e\n\u003ctd\u003eRead ML and the termination from the label. The two ID examples differ in both.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/stanki-used.com.ua\/image\/PASSPORT\/CNC\/LS-403_LS-403C.pdf\"\u003eHEIDENHAIN electrical and mechanical data (PDF copy)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.fbmsrl.com\/wp-content\/uploads\/2016\/09\/Istruzioni-di-montaggio-LS-403-LS-403C.pdf\"\u003eHEIDENHAIN installation and reference data (PDF copy)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe sealed scale mounts to one machine member and the scanning head moves with the other. Align the mounting faces to the guideway and verify the head-to-scale relationship over the full travel. Use the mounting form and dimensions for the actual end blocks or spar. The original full manual recommends the spar for measuring lengths above 620 mm and for certain higher-vibration installations. Check the manual for its prescribed transport brace removal, seal orientation and clearances before moving the axis. \u003ca href=\"https:\/\/stanki-used.com.ua\/image\/PASSPORT\/CNC\/LS-403_LS-403C.pdf\"\u003eHEIDENHAIN mounting faces, spar and alignment (PDF copy)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.fbmsrl.com\/wp-content\/uploads\/2016\/09\/Istruzioni-di-montaggio-LS-403-LS-403C.pdf\"\u003eMounting sketches and measuring length (PDF copy)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe optical head generates two sinusoidal current signals and a separate reference signal. A compatible receiver converts the currents and interpolates position between 20 µm periods. A control using distance-coded marks can recover the machine reference after crossing the required sequence. A smooth movement reading with a reference alarm points toward the reference path or the control setting. Check the current-input receiver or EXE\/VRZ\/TNC path before substituting a scale or converter. \u003ca href=\"https:\/\/stanki-used.com.ua\/image\/PASSPORT\/CNC\/LS-403_LS-403C.pdf\"\u003eHEIDENHAIN measurement and follow-up electronics (PDF copy)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.heidenhain.com\/products\/encoders\/signal-converters\/adaptation-to-interfaces\"\u003eHEIDENHAIN 11 µApp interface conversion\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eFor the \u003cstrong\u003e9-contact HEIDENHAIN arrangement in the full mounting manual's electrical connection diagram\u003c\/strong\u003e, match the contact numbers on the fitted connector. Use the two contacts within each signal pair as shown in the drawing. Verify this against the machine-side connection, especially on an adapted scale.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"LS 403 \/ LS 403 C 9-contact function groups\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eLS 403 \/ LS 403 C 9-contact function groups\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eContacts\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHEIDENHAIN manual function\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3 \/ 4\u003c\/th\u003e\n\u003ctd\u003e5 V lamp supply \/ 0 V return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1 and 2\u003c\/th\u003e\n\u003ctd\u003eFirst incremental current pair (0° electrical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e5 and 6\u003c\/th\u003e\n\u003ctd\u003eSecond incremental current pair (90° electrical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e7 and 8\u003c\/th\u003e\n\u003ctd\u003eReference current pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e9 \/ connector shell\u003c\/th\u003e\n\u003ctd\u003eInner shield \/ outer shield to housing and mounting block, respectively, in the cited drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse the exact diagram for pair polarity and shield termination. A current output requires the specified receiving circuit. \u003ca href=\"https:\/\/stanki-used.com.ua\/image\/PASSPORT\/CNC\/LS-403_LS-403C.pdf\"\u003eHEIDENHAIN electrical connection and shield layout, printed p. 34 (PDF copy)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThis is a machine-axis scale with a head lead. The original HEIDENHAIN cable table lists \u003cstrong\u003e246662-xx\u003c\/strong\u003e standard and \u003cstrong\u003e235807-xx\u003c\/strong\u003e armoured extensions for the regular\/armoured connector-ended scale lead, and \u003cstrong\u003e246660-xx\u003c\/strong\u003e or \u003cstrong\u003e235804-xx\u003c\/strong\u003e for the flange-socket arrangement. Confirm the length suffix and connector before ordering. The manual gives total cable limits of 30 m standard or 20 m armoured for the specified setup. Check the installed electronics for any tighter limit. \u003ca href=\"https:\/\/stanki-used.com.ua\/image\/PASSPORT\/CNC\/LS-403_LS-403C.pdf\"\u003eHEIDENHAIN extension cable table and limits, printed p. 35 (PDF copy)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolate and secure the axis, including gravity or counterbalance energy, before touching the scale.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecord.\u003c\/strong\u003e Note the position and direction when the reading drops out or the reference search fails. Photograph the seal condition, mounting end blocks, cable loop and any converter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect.\u003c\/strong\u003e Check the head fasteners, mounting and parallelism, deformed lips, evidence of coolant ingress, crushed cable and connector seating. Follow the HEIDENHAIN method for protective measures and cleaning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the detached extension.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Preserve individual signal pairs and the inner and outer shield layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompare supply and readout.\u003c\/strong\u003e A qualified technician can check the specified lamp supply at the approved breakout while the machine is in the authorized test state. A healthy supply alone leaves the head signals untested. Check current-signal quality and reference with a compatible tester, then compare at the control. A dropout at the same travel point suggests scale geometry or contamination. A signal lost only at the receiver points toward cabling or input.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eHEIDENHAIN documents the original scale for compatible VRZ displays, TNC controls and EXE interpolating electronics. The Kunzmann machine manual illustrates a historical TNC application. Verify the installed interface, reference mode and axis travel before replacing an original. \u003ca href=\"https:\/\/stanki-used.com.ua\/image\/PASSPORT\/CNC\/LS-403_LS-403C.pdf\"\u003eHEIDENHAIN downstream electronics (PDF copy)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.kunzmann-fraesmaschinen.de\/wp-content\/uploads\/simple-file-list\/UF4-UF5_WUF5_WF5_1984_1992\/Anleitung_WF5_TNC155.pdf\"\u003eKunzmann WF5 \/ TNC 155 machine documentation (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eFor a linear axis, alignment means parallel fit across travel and a verified machine reference. Record the original orientation, head position, measuring length and CNC reference mode before removal. After fitting and checking clearance through the approved travel, follow the machine's C-scale referencing procedure and verify a known displacement. This linear scale has no servo commutation offset of its own. \u003ca href=\"https:\/\/www.fbmsrl.com\/wp-content\/uploads\/2016\/09\/Istruzioni-di-montaggio-LS-403-LS-403C.pdf\"\u003eHEIDENHAIN measuring length and reference drawings (PDF copy)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/stanki-used.com.ua\/image\/PASSPORT\/CNC\/LS-403_LS-403C.pdf\"\u003eHEIDENHAIN LS 403 \/ LS 403 C full mounting instructions (PDF copy)\u003c\/a\u003e. Manufacturer manual with mounting, technical data, contact diagram and cable families.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.fbmsrl.com\/wp-content\/uploads\/2016\/09\/Istruzioni-di-montaggio-LS-403-LS-403C.pdf\"\u003eHEIDENHAIN mounting instruction 226 557 03 (PDF copy)\u003c\/a\u003e. Illustrated mechanical installation and C reference marks.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.kunzmann-fraesmaschinen.de\/wp-content\/uploads\/simple-file-list\/UF4-UF5_WUF5_WF5_1984_1992\/Anleitung_WF5_TNC155.pdf\"\u003eKunzmann WF5 TNC 155 machine instructions (PDF)\u003c\/a\u003e. Check the installed OEM axis configuration and wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.heidenhain.com\/products\/encoders\/signal-converters\/adaptation-to-interfaces\"\u003eHEIDENHAIN converter overview\u003c\/a\u003e. Match the current-input class and the receiver before retrofitting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e","brand":"SpareFaber","offers":[{"title":"Default Title","offer_id":51118245871781,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/HEIDENHAINLS403C.jpg?v=1794126011","url":"https:\/\/www.sparefaber.com\/products\/heidenhain-ls-403-c","provider":"SpareFaber","version":"1.0","type":"link"}