{"product_id":"hengstler-ad36-biss-c","title":"Hengstler ACURO AD36 BiSS-C Encoder | Technical Guide \u0026 Service | Site Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eTracing a Hengstler AD36 BiSS-C feedback fault?\u003c\/strong\u003e SpareFaber can visit your UAE site to diagnose feedback dropouts, check the motor harness and drive setup, and verify installation and commutation alignment. Ask about bench evaluation if the motor or encoder has already been removed.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my AD36 variant\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a BiSS-C fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Hengstler AD36 BiSS-C technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or bench evaluation\u003c\/h2\u003e\n\u003cp\u003eFor a site visit, note whether the fault starts at power-up, during motion or only when nearby equipment switches. For bench evaluation, share the full encoder label, motor order code, drive model and firmware, exact fault and photos of both feedback connectors. If alignment is in question, keep the encoder on the motor so the as-found position can be recorded.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell lists \u003cstrong\u003eAD36-0019\u003c\/strong\u003e and \u003cstrong\u003eAD36-1219\u003c\/strong\u003e under BiSS test and alignment support for the TI-5000JX. With the matching BiSS setup, a technician can check whether absolute position and direction track shaft movement, isolate the motor harness with a verified test lead, and measure commutation alignment on the assembled motor. Confirm the Athena profile, firmware and motor connector before connecting. \u003ca href=\"https:\/\/www.mitchell-electronics.com\/product-catalog\/\"\u003eMitchell test and alignment support\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eMitchell also lists both profiles under \u003cstrong\u003eTI-3000JX Generic BiSS\u003c\/strong\u003e run-test support. A guarded run requires the matched feedback and power leads, amplifier setup, verified motor pole count and established commutation. Check the feedback first. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/14049548139675-WinTI5000JX-is-being-replaced-with-Athena-New-Features\"\u003eMitchell TI-3000JX run-test profiles\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eHengstler ACURO AD36 technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor and drive applications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment and memory\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eRead the whole AD36 label\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAD36\/1219AF.0CBEB\u003c\/strong\u003e, item \u003cstrong\u003e0541374\u003c\/strong\u003e, is the digital BiSS-C variant used as the reference here. \u003cstrong\u003e1219\u003c\/strong\u003e gives 12 turn bits and 19 angle bits, \u003cstrong\u003eA\u003c\/strong\u003e is the 5 V supply code, \u003cstrong\u003eF.0C\u003c\/strong\u003e is the 8 mm through-bore with F spring tether, \u003cstrong\u003eBE\u003c\/strong\u003e is digital BiSS-C and the final \u003cstrong\u003eB\u003c\/strong\u003e specifies the tangential 0.5 m lead. Match the shaft, supply, protocol and cable exit to the original label before ordering.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Searchable Hengstler AD36 match codes and item numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eVerified examples with different interfaces, shafts and leads\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eMatch code and item number\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eShaft and termination\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFeedback at 5 V nominal\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"https:\/\/www.hengstler.com\/products\/rotary-encoders\/absolute-encoders\/ad36\/ad361219af0cbeb\"\u003eAD36\/1219AF.0CBEB\u003cbr\u003e0541374\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003e8 mm through-bore, tangential 0.5 m lead\u003c\/td\u003e\n\u003ctd\u003eBiSS-C, 19-bit single-turn + 12-bit multiturn. Digital BE output.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"https:\/\/www.hengstler.com\/products\/rotary-encoders\/absolute-encoders\/ad36\/ad361219af0rbv0\"\u003eAD36\/1219AF.0RBV0\u003cbr\u003e0541339\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003e8 mm blind hub, 12-pole PCB connection\u003c\/td\u003e\n\u003ctd\u003eBiSS-C, 19 + 12 bits, plus 2,048 periods\/rev of 1 Vpp sine\/cosine (BV).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"https:\/\/www.hengstler.com\/products\/rotary-encoders\/absolute-encoders\/ad36\/ad360019af0cbv0\"\u003eAD36\/0019AF.0CBV0\u003cbr\u003e0545067\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003e8 mm through-bore, 12-pole PCB connection\u003c\/td\u003e\n\u003ctd\u003eBiSS-C, 19-bit single-turn, plus 2,048 periods\/rev of 1 Vpp sine\/cosine (BV).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"https:\/\/www.hengstler.com\/products\/rotary-encoders\/absolute-encoders\/ad36\/ad360019af0csc0\"\u003eAD36\/0019AF.0CSC0\u003cbr\u003e0541270\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003e8 mm through-bore, 12-pole PCB connection\u003c\/td\u003e\n\u003ctd\u003eSSI Gray, 19-bit single-turn, with 1 Vpp sine\/cosine (SC).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe family also includes BiSS-B (\u003cstrong\u003eBI\u003c\/strong\u003e\/\u003cstrong\u003eBC\u003c\/strong\u003e) and 7–30 V (\u003cstrong\u003eE\u003c\/strong\u003e) versions. A similar label or connector can hide a different interface or supply requirement. \u003ca href=\"https:\/\/dynapar.perfioncloud.com\/PerfionAPIService\/Perfion\/File.aspx?id=5c0120c6-4e09-427c-85c3-c999c3fefe9b#page=6\"\u003eHengstler order key (PDF, p. 6)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eHengstler’s catalogue lists \u003cstrong\u003e0541374\u003c\/strong\u003e as available to buy, checked 7 November 2026. Confirm availability and lifecycle for a motor-maker-specific suffix with the motor OEM. \u003ca href=\"https:\/\/www.hengstler.com\/products\/rotary-encoders\/absolute-encoders\/ad36\/ad361219af0cbeb\"\u003eHengstler 0541374 catalogue record\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications for AD36\/1219AF.0CBEB\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"AD36 item 0541374 specifications\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eHengstler item 0541374, F.0C mounting and BE interface\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue for this variant\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring method\u003c\/th\u003e\n\u003ctd\u003eOptical absolute angle, with a mechanical gear train for the multiturn position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition resolution\u003c\/th\u003e\n\u003ctd\u003e19 bits (524,288 positions\/rev) and 12 turn bits (4,096 distinguishable turns)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±35 arcseconds typical. This is separate from the resolution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEncoder supply and load\u003c\/th\u003e\n\u003ctd\u003e5 V DC, −5%\/+10% (4.75–5.50 V at the encoder). 150 mA typical without load. Verify polarity before applying power.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical interface\u003c\/th\u003e\n\u003ctd\u003eBiSS-C binary. Differential RS-422 clock and data. BE lead carries digital feedback.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvelope and fit\u003c\/th\u003e\n\u003ctd\u003eØ37.5 mm housing, Ø8 mm through-bore, F spring tether, IP40 housing and shaft entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMating shaft motion\u003c\/th\u003e\n\u003ctd\u003e±0.5 mm axial endplay and ±0.05 mm radial runout, hollow or hub designs per Hengstler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEncoder speed\u003c\/th\u003e\n\u003ctd\u003e10,000 rpm continuous, 12,000 rpm short term. Check the motor’s own speed limit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e−40 to +120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dynapar.perfioncloud.com\/PerfionAPIService\/Perfion\/File.aspx?id=5c0120c6-4e09-427c-85c3-c999c3fefe9b\"\u003eHengstler AD36 data sheet (PDF, pp. 1–2)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eHow the AD36 fits the motor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eF.0C through-bore\u003c\/strong\u003e fits over the motor’s encoder shaft. Hengstler’s assembly example uses a retaining washer and nut on the exposed shaft. The F spring plate attaches to the motor end face and keeps the housing from turning while allowing the designed flex. Check for a loose shaft retainer, loose tether screws, a bent spring plate or a cable pulling on the housing. Use the motor drawing for the actual retainer and tightening values.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eF.0R blind hub\u003c\/strong\u003e uses a different attachment. Hengstler’s installation drawing B shows a central M4 screw and 2 N·m for that illustrated screw. The through-bore assembly has its own hardware. Compare the motor’s shaft projection, pilot and tether location against the corresponding drawing before fitting. \u003ca href=\"https:\/\/dynapar.perfioncloud.com\/PerfionAPIService\/Perfion\/File.aspx?id=ef98885c-3ecd-4a5e-8233-b9be2f4d07c2#page=1\"\u003eInstallation 2 541 033, assembly A\/B (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/dynapar.perfioncloud.com\/PerfionAPIService\/Perfion\/File.aspx?id=5c0120c6-4e09-427c-85c3-c999c3fefe9b#page=3\"\u003eAD36 hub and through-bore drawings (PDF, pp. 3–4)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eHow BiSS-C exchanges position with the drive\u003c\/h2\u003e\n\u003cdiv style=\"background: #eaf5f4; border-left: 4px solid #237e75; border-radius: 0.35rem; padding: 0.75rem 1rem;\"\u003e\n\u003cp\u003e\u003cstrong\u003eClock goes from drive to encoder. Data comes back from encoder to drive.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive initiates each reading on CLOCK+\/−. The encoder returns a timed digital reply on DATA+\/−. A compatible drive can read absolute position while the shaft is stationary.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eFor \u003cstrong\u003e0541374\u003c\/strong\u003e, the reply carries 31 position bits (12 turn + 19 angle), encoder warning and error information, and a 6-bit cyclic redundancy check (CRC). The CRC checks whether the received bits are consistent. A clean frame can still describe a shaft fitted at the wrong mechanical zero. The mechanical turn counter gives this variant absolute multiturn position without a backup battery. The machine reference and motor commutation offset are separate settings.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/biss-interface.com\/wp-content\/uploads\/2024\/07\/BiSS_C_protocol_D2en.pdf#page=5\"\u003eBiSS-C protocol, point-to-point link (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.renesas.com\/en\/document\/apn\/rzt2l-group-biss-c-sample-program#page=19\"\u003eRenesas BiSS-C example with AD36\/1219AF.0CBEB (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified encoder-side pinout\u003c\/h2\u003e\n\u003cp\u003eUse the \u003cstrong\u003eencoder receptacle mating face\u003c\/strong\u003e in Hengstler’s drawing, with row \u003cstrong\u003eb\u003c\/strong\u003e above row \u003cstrong\u003ea\u003c\/strong\u003e and contacts 1–6 from left to right as drawn. The plug’s mating face mirrors this view. Older Hengstler wire colours differ. Verify the actual pin numbers and lead before making a connection.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"AD36 12-pole PCB connector pinout\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eAD36 six-wire BE lead and corresponding signal names at AKD X10\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eAD36 pin\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHengstler current colours\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eAKD X10, digital BiSS-C\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e+5 V supply\u003c\/th\u003e\n\u003ctd\u003e1b\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e0 V return\u003c\/th\u003e\n\u003ctd\u003e4b\u003c\/td\u003e\n\u003ctd\u003eBrown\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClock +\u003c\/th\u003e\n\u003ctd\u003e2b\u003c\/td\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClock −\u003c\/th\u003e\n\u003ctd\u003e5a\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eData +\u003c\/th\u003e\n\u003ctd\u003e6b\u003c\/td\u003e\n\u003ctd\u003ePink\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eData −\u003c\/th\u003e\n\u003ctd\u003e1a\u003c\/td\u003e\n\u003ctd\u003eGrey\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThis table cross-references the six signals. For a complete harness, verify the motor bulkhead drawing, the shield bond and the drive’s approved sense wiring. AKD X10 has separate sense pins \u003cstrong\u003e4\u003c\/strong\u003e and \u003cstrong\u003e5\u003c\/strong\u003e. The six-wire BE lead has no dedicated sense conductors. For a BV or SC lead, use the full 12-pole Hengstler diagram for the additional analog and sense wires.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dynapar.perfioncloud.com\/PerfionAPIService\/Perfion\/File.aspx?id=ef98885c-3ecd-4a5e-8233-b9be2f4d07c2#page=2\"\u003eHengstler receptacle view and old\/new colours (PDF, §7)\u003c\/a\u003e · \u003ca href=\"https:\/\/webhelp.kollmorgen.com\/kas2.11\/Content\/AKD-BPTM%20Install\/e\/AKD_single_09_14_01_Feedback%20connector.htm\"\u003eKollmorgen AKD X10 pin assignment\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eInternal motor leads and cable part numbers\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Hengstler internal leads and mounting accessories\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eHengstler leads with encoder plug and open conductors\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eApplication\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eOrder number\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eLength or purpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSix-wire lead for BE digital BiSS-C\u003c\/th\u003e\n\u003ctd\u003eE1 541 152\u003c\/td\u003e\n\u003ctd\u003e0.5 m, for cable clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLonger six-wire BE leads\u003c\/th\u003e\n\u003ctd\u003eE1 541 186 \/ E1 541 138\u003c\/td\u003e\n\u003ctd\u003e1.5 m \/ 3.0 m, for cable clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e12-wire lead for BV BiSS-C plus 1 Vpp\u003c\/th\u003e\n\u003ctd\u003eE1 541 048 \/ E1 541 117\u003c\/td\u003e\n\u003ctd\u003eBoth 0.5 m. First for clip, second for screen clamp plus clip.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCable exit and shield hardware\u003c\/th\u003e\n\u003ctd\u003eE2 541 039 \/ E2 541 034 \/ 1 541 066\u003c\/td\u003e\n\u003ctd\u003eAxial clip \/ tangential clip \/ screen clamp, respectively\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe listed leads end in open conductors. For a motor bulkhead such as M23, verify the OEM connector insert, pinout, shield termination and strain relief separately. Preserve the OEM shield path. Hengstler’s cable clip is a cable exit, so anchor the lead separately near the encoder. \u003ca href=\"https:\/\/dynapar.perfioncloud.com\/PerfionAPIService\/Perfion\/File.aspx?id=5c0120c6-4e09-427c-85c3-c999c3fefe9b#page=7\"\u003eHengstler cable and accessory order numbers (PDF, p. 7)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eFor Beckhoff AL2000, AM3000 or AM3500 installations with the documented 17-pole motor connection and BiSS plus sine\/cosine feedback, Beckhoff lists the external \u003cstrong\u003eZK4510-0000-xxxx\u003c\/strong\u003e cable for fixed installation and \u003cstrong\u003eZK4510-0020-xxxx\u003c\/strong\u003e for high-flex service. The drive end is a 15-pole D-sub. Match the complete motor code to the drawing. \u003ca href=\"https:\/\/infosys.beckhoff.com\/content\/1033\/ax5000_usermanual\/13129609739.html?id=6922417215662791556\"\u003eBeckhoff cable drawings and connector views\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks on the machine\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eStart isolated.\u003c\/strong\u003e Record drive faults and configuration. Lock out all supplies, secure the axis and load, and verify DC bus discharge according to the drive manual. With the harness disconnected from both the drive and encoder, inspect for backed-out pins, dirt, fluid, corrosion and a damaged latch. Meter each conductor end to end, then check for unintended shorts between conductors and to the shell or shield. Gently flex the isolated cable at its strain reliefs. Compare shield continuity with the wiring drawing and keep an insulation tester off the electronics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCheck voltage under load.\u003c\/strong\u003e A qualified technician can fit an approved breakout while isolated and then use the drive’s approved feedback diagnostic state with motion prevented. Set the meter to DC volts, leads in V and COM. For the 5 V A variant, use red at \u003cstrong\u003e1b\u003c\/strong\u003e and black at \u003cstrong\u003e4b\u003c\/strong\u003e. Expect \u003cstrong\u003e4.75–5.50 V\u003c\/strong\u003e at the encoder. Compare the drive and encoder readings if the voltage drops. This check establishes supply health. Use a BiSS-C master or approved differential probing for the serial signals.\u003c\/p\u003e\n\u003ch3\u003eFollow the clock, then the reply\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"BiSS-C fault isolation by observed symptom\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eWhat the observation tells you and where to look next\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation with the axis secured\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eNext check\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo clock at the encoder\u003c\/th\u003e\n\u003ctd\u003eCheck the drive’s feedback mode and port. Clock present at the drive but absent at the encoder points to the outgoing pair or a connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClock and supply reach the encoder, but no reply returns\u003c\/th\u003e\n\u003ctd\u003eCheck clock polarity, the return pair and contact seating. Compare at both ends with a verified harness or bench master before condemning the encoder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReply arrives, but the drive reports communication errors\u003c\/th\u003e\n\u003ctd\u003eCompare configured bit count with the label. Then check supply under load, cable routing, pair integrity and shield termination. AKD F405 is a BiSS watchdog fault.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCRC passes, but a warning or error bit is set\u003c\/th\u003e\n\u003ctd\u003eThe drive received the frame. Read the encoder’s status with the matched diagnostic tool and check the conditions in the encoder manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValid position, but the motor starts roughly after feedback work\u003c\/th\u003e\n\u003ctd\u003eCheck shaft retention, feedback direction, motor phase order and commutation offset before another run. If motor position is correct and the machine still slips, inspect the mechanical load path.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.kollmorgen.com\/en-us\/developer-network\/akd-fault-messages\"\u003eKollmorgen AKD fault list\u003c\/a\u003e · \u003ca href=\"https:\/\/dynapar.perfioncloud.com\/PerfionAPIService\/Perfion\/File.aspx?id=dc4ff59a-0864-45cc-b505-44d99d7c7b6d\"\u003eHengstler ACURO BiSS-C technical manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eKollmorgen documents the \u003cstrong\u003eAD36-1219\u003c\/strong\u003e digital profile on the original AKD. In its setup note, the values are \u003cstrong\u003eFB1.SELECT = 34\u003c\/strong\u003e, \u003cstrong\u003eFB1.BISSBITS = 31\u003c\/strong\u003e and \u003cstrong\u003eFB1.ENCRES = 1048576\u003c\/strong\u003e. The \u003cstrong\u003eAD36-0019\u003c\/strong\u003e profile uses 19 bits and an ENCRES value of 4294967295 in the same note. Use these as comparison values for that drive and supported profile with the axis disabled. Check the drive revision and preserve the existing parameter set before changes. \u003ca href=\"https:\/\/www.kollmorgen.com\/en-us\/developer-network\/biss-c\"\u003eKollmorgen AKD BiSS-C settings\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eOn a Kollmorgen \u003cstrong\u003eAKM2, AKM3 or AKM4\u003c\/strong\u003e, older cable documentation lists AD36 with \u003cstrong\u003eAA\u003c\/strong\u003e (single-turn) or \u003cstrong\u003eAB\u003c\/strong\u003e (multiturn) as \u003cstrong\u003eBiSS-B\u003c\/strong\u003e. Read the actual encoder suffix before using this BiSS-C wiring or profile. For a Beckhoff AX5000, Beckhoff distinguishes pure digital BiSS-C on the AX572x card at X41\/X42 from BiSS-C plus analog sine\/cosine at X11\/X21. Confirm the drive, card, firmware and motor option together. \u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/KM2G-Cable-SelectionGuide-RevA.pdf\"\u003eKollmorgen motor feedback options (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/infosys.beckhoff.com\/content\/1033\/ax5000_function_doku_hw2\/4138951435.html\"\u003eBeckhoff AX5000 encoder interface\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eCommutation alignment and motor memory\u003c\/h2\u003e\n\u003cp\u003eRecord as-found commutation and export the original drive settings before disturbing a readable assembly. The correct offset depends on the motor, phase order, feedback direction and installed position. On AKD applications using a configured drive offset, \u003cstrong\u003eMOTOR.PHASE\u003c\/strong\u003e sets the offset in electrical degrees. Use the exact motor’s approved commissioning method to verify it after fitting. Any phase-finding test that can move the shaft belongs on a secured setup under a qualified technician’s control.\u003c\/p\u003e\n\u003cp\u003eHengstler identifies OEM memory in BiSS-C banks 4–7 and reserves banks 0–3 for configuration and manufacturer data. If the motor OEM requires a memory transfer, read and save the original with the documented profile, restore only approved OEM data to a verified matching part and read it back. Verify alignment and machine reference separately. A fixed bench lockup angle and an OEM memory map for the specific motor installation must come from that motor’s documentation. \u003ca href=\"https:\/\/dynapar.perfioncloud.com\/PerfionAPIService\/Perfion\/File.aspx?id=ef98885c-3ecd-4a5e-8233-b9be2f4d07c2#page=2\"\u003eHengstler BiSS-C bank map (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/webhelp.kollmorgen.com\/AKD\/English\/Content\/CommandParamRefGuide\/MOTOR\/MOTOR.PHASE.htm\"\u003eAKD MOTOR.PHASE reference\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, manuals and training notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/dynapar.perfioncloud.com\/PerfionAPIService\/Perfion\/File.aspx?id=5c0120c6-4e09-427c-85c3-c999c3fefe9b\"\u003eHengstler AD36 data sheet, 081123 EN (PDF)\u003c\/a\u003e. Specs and pins on pp. 1–2, shaft drawings on pp. 3–5, order key and cables on pp. 6–7.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/dynapar.perfioncloud.com\/PerfionAPIService\/Perfion\/File.aspx?id=ef98885c-3ecd-4a5e-8233-b9be2f4d07c2\"\u003eHengstler AD36 installation instructions 2 541 033 (PDF)\u003c\/a\u003e. Assembly drawings and connector orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/dynapar.perfioncloud.com\/PerfionAPIService\/Perfion\/File.aspx?id=dc4ff59a-0864-45cc-b505-44d99d7c7b6d\"\u003eHengstler ACURO BiSS-C technical manual 2 547 133 (PDF)\u003c\/a\u003e. Status and register details.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.kollmorgen.com\/sites\/default\/files\/public_downloads\/AKD_Installation_en_Rev-AB.pdf#page=130\"\u003eKollmorgen AKD installation manual Rev. AB, §9.12.8.2 (PDF)\u003c\/a\u003e. X10 digital BiSS-C wiring example.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/35204185834779-BiSS-Serial-Protocol\"\u003eMitchell BiSS serial protocol\u003c\/a\u003e. Mode B, Mode C and options with analog sine\/cosine.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eAsk SpareFaber about on-site diagnosis, alignment or bench testing\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"SpareFaber","offers":[{"title":"Default Title","offer_id":51116382093477,"sku":"GTY2","price":128.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/HengstlerACUROAD36BiSS-CEncoderTechnicalGuide_ServiceServiceVisitforInstallation_Repair_Alignment.jpg?v=1794070532","url":"https:\/\/www.sparefaber.com\/products\/hengstler-ad36-biss-c","provider":"SpareFaber","version":"1.0","type":"link"}