{"product_id":"hengstler-ri58-o-0552676","title":"Hengstler RI58-O 0552676 Push-Pull Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for RI58-O installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Hengstler RI58-O 0552676 Push-Pull Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eWith the approved load and supply, a qualified bench test can compare A\/B phase, N, alarm and count through a known turn. Observe the same channels at the machine input to isolate a harness or receiver problem. Mitchell exact profile support is unverified.\u003c\/p\u003e\n\u003ch2\u003eHengstler RI58-O 0552676 Push-Pull Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eRI58-O\/ 1024EK.42KB-P0\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRI58-O\/ 1024EK.42KB-P0 \/ 0552676\u003c\/th\u003e\n\u003ctd\u003eK.42 codes a 10 mm solid shaft, M3 clamping flange and IP65 family configuration. B codes a radial PVC cable.\u003c\/td\u003e\n\u003ctd\u003e1,024 pulses\/rev, E supply 10–30 V DC, K push-pull. Verify the exact P0 configuration with Hengstler.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRI58-O\/ 1024EK.42KB \/ 0522462\u003c\/th\u003e\n\u003ctd\u003eSame published core flange, shaft and cable codes.\u003c\/td\u003e\n\u003ctd\u003eSame published core count and output codes. The ordering table lists this as a separate part.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRI58 family, I or R output options\u003c\/th\u003e\n\u003ctd\u003eCheck full type, mounting and connection codes.\u003c\/td\u003e\n\u003ctd\u003eI adds complementary push-pull outputs. R uses RS-422 with alarm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eHengstler lists item 0552676 as quote only in its exact product record. Request current orderability and production status for the complete P0 code.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for RI58-O\/ 1024EK.42KB-P0\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for RI58-O\/ 1024EK.42KB-P0\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e1,024 pulses per revolution, A\/B quadrature and N reference. Receiver edge counting can produce 4,096 counts\/rev.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower \/ output\u003c\/th\u003e\n\u003ctd\u003eE code 10–30 V DC. K code push-pull, A\/B\/N plus alarm. 200 kHz family maximum pulse frequency for push-pull.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit \/ lead\u003c\/th\u003e\n\u003ctd\u003eK.42 clamping M3 flange, 10 mm shaft. B radial PVC cable. Select the actual mounting drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eK.42 catalogue IP65 configuration. Check the data sheet's shaft-entry qualification and the P0 configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.farnell.com\/datasheets\/3770955.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eMeasure the 10 mm shaft and read the clamping-flange drawing before selecting a coupling. Check the mating pilot, shaft engagement, coupling alignment and cable bend clearance. Use the correct fasteners and torque for the actual bracket and coupling. Check thrust and radial loads against the family conditions.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eA and B change state in quadrature as the shaft rotates. Their lead or lag gives direction. N is the index reference and the alarm line is separate. The K output drives both high and low with a common reference. Check the receiver's input ratings and threshold for the installed supply.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the K column in the manufacturer's PVC cable A\/B table. It applies to the B radial PVC lead when the original harness matches the exact order code. Identify each conductor by its colour and confirm any OEM splices.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"RI58 K output with B cable\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eRI58 K output with B cable\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWire\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply \/ return\u003c\/th\u003e\n\u003ctd\u003eRed \/ black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA \/ B \/ N\u003c\/th\u003e\n\u003ctd\u003eWhite \/ green \/ yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlarm\u003c\/th\u003e\n\u003ctd\u003eYellow with black tracer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eScreen\u003c\/th\u003e\n\u003ctd\u003eConnected to encoder housing per datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eTerminate the screen per the machine EMC drawing and account for its intended housing bond during isolated short checks.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe B code has a factory radial lead. Hengstler's accessories list 3 280 114 as 10-core screened PVC cable by length. Confirm that the selected cable and termination match the existing machine harness and output speed. For a repair splice, verify conductor mapping and screen continuity after both ends are disconnected.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo counts in either direction\u003c\/th\u003e\n\u003ctd\u003eCheck loaded supply, input mode and whether the coupling actually turns the encoder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDirection changes randomly or count jumps\u003c\/th\u003e\n\u003ctd\u003eCompare A and B edges at both ends. Inspect cable routing and strain, input thresholds and coupling play.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCounts are fine but origin is lost\u003c\/th\u003e\n\u003ctd\u003eCheck N at the controller and the homing logic. Check the alarm output independently.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eHengstler lists CNC axes, packaging machines, drives and other machinery for the RI58 family. Confirm the exact machine's input voltage, pulse rate, count mode and mounting.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eAlign the coupling mechanically, establish count direction and verify index or machine home. Capture the existing PLC scaling and reference position before changing the encoder. Use the OEM commutation procedure if this encoder participates in a motor control system.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/3770955.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.hengstler.com\/products\/rotary-encoders\/incremental-encoders\/ri58\/ri58o1024ek42kbp0\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/3770955.pdf#page=3\"\u003eElectrical tables, PVC A\/B cable\u003c\/a\u003e. Use the K column.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/3770955.pdf#page=5\"\u003eClamping flange dimensions\u003c\/a\u003e. Use the radial B drawing.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/3770955.pdf#page=7\"\u003eHengstler ordering information\u003c\/a\u003e. Decodes E, K.42, K and B. Lists 0522462 as a separate match code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118431142053,"sku":"TCG66","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/HengstlerRI58-O0552676Push-PullEncoder.jpg?v=1794132481","url":"https:\/\/www.sparefaber.com\/products\/hengstler-ri58-o-0552676","provider":"SpareFaber","version":"1.0","type":"link"}