{"product_id":"keb-dl4-sg-l8-cf-resolver-technical-guide","title":"KEB DL4 SG-L8 CF Resolver Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sparefaber-encoder-guide\"\u003e\n\u003cp\u003e\u003cstrong\u003eKEB DL4 SG-L8 CF · Resolver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE site visits and send-in evaluation for the KEB DL4 SG-L8 CF. Use this guide to identify the fitted feedback, prepare the right cable and drawing, and investigate faults before ordering parts or starting alignment.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e\u003c\/p\u003e\n\u003cnav aria-label=\"Guide sections\"\u003e\u003cp\u003e\u003ca href=\"#identify\"\u003eFind your part\u003c\/a\u003e · \u003ca href=\"#testing\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mechanical-fit\"\u003eMechanical fit\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#availability\"\u003eAvailability\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eDocuments\u003c\/a\u003e · \u003ca href=\"#faq\"\u003eFAQ\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the motor nameplate, complete part number and fitted feedback label. Forced ventilation. KEB catalogue SG-L8 CF reference has 580 N·m stall torque and three speed\/winding rows. Preserve fan and terminal box drawing.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eWhat to identify\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCatalogue reference\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame and length\u003c\/td\u003e\n\u003ctd\u003eSG \/ L8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling code\u003c\/td\u003e\n\u003ctd\u003eCF, independent forced ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical family\u003c\/td\u003e\n\u003ctd\u003eNominal 400 V DL4, eight motor poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback\u003c\/td\u003e\n\u003ctd\u003eStandard resolver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eInclude any special suffixes and clear photos of the mating connectors and the feedback mount.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"testing\"\u003e\u003ch2\u003eWhat specialist testing can establish\u003c\/h2\u003e\n\u003cp\u003eCompare resolver excitation and the two secondary signals using the fitted connection diagram. Check repeatability and polarity on an appropriate bench setup. Confirm the resolver type and signal levels from the fitted order before selecting a test profile.\u003c\/p\u003e\n\u003cp\u003eSpareFaber can assess a site visit or a send-in evaluation. Direct encoder checks and complete motor run tests require confirmed hardware and independent setup decisions.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"specifications\"\u003e\u003ch2\u003eReference specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCatalogue value\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eScope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated torque (N·m)\u003c\/td\u003e\n\u003ctd\u003e530 \/ 470 \/ 320 across the listed windings\u003c\/td\u003e\n\u003ctd\u003eKEB DL4 table for this stack and cooling code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStall torque reference (N·m)\u003c\/td\u003e\n\u003ctd\u003e580\u003c\/td\u003e\n\u003ctd\u003eKeep the actual speed\/winding row and cooling conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue motor mass (kg)\u003c\/td\u003e\n\u003ctd\u003e203\u003c\/td\u003e\n\u003ctd\u003eCheck lifting points and the fitted brake and terminal box weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eCF, forced air\u003c\/td\u003e\n\u003ctd\u003eConfirm fan supply and service access on the actual order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"mechanical-fit\"\u003e\u003ch2\u003eMechanical fit\u003c\/h2\u003e\n\u003cp\u003eUse the SG L8 CF drawing. Measure flange\/pilot and shaft fit, and allow access to the external blower and terminal box. Compare the brake package and connector arrangement with the actual nameplate.\u003c\/p\u003e\n\u003cp\u003eCheck the fitted part’s complete drawing before choosing a substitute. Compare shaft or bore, mounting dimensions, locating features and harness clearance.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eConfirm the excitation pair and sine and cosine secondary pairs from the KEB wiring drawing. Document signal polarity, screen routing and actual resolver cycles per revolution for this assembly.\u003c\/p\u003e\n\u003cp\u003eIdentify the connector face and drawing revision. Approved service personnel should isolate power, secure the load and verify the relevant wiring before any powered checks.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"cables\"\u003e\u003ch2\u003eInternal wiring and machine cables\u003c\/h2\u003e\n\u003cp\u003eConfirm the complete feedback cable part number at both ends. Document motor-side connector or terminal-box arrangement, receiver, shield termination and cable length. Check cooling, brake and thermal sensor conductors against their own diagrams.\u003c\/p\u003e\n\u003cp\u003eSend clear photos of both mating connectors and the cable label. Note where the harness flexes and whether a connector, cable or drive was recently replaced.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObserved symptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to check\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback fault with stable motor temperature\u003c\/td\u003e\n\u003ctd\u003eCheck the fitted feedback code, harness and connection diagram first.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature rises during sustained load\u003c\/td\u003e\n\u003ctd\u003eCheck installed CF blower rating, airflow and overload history before interpreting motor data.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition changes after encoder or resolver work\u003c\/td\u003e\n\u003ctd\u003eCompare saved reference, rotation and the exact sensor holder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\u003csection id=\"alignment\"\u003e\u003ch2\u003eAlignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord the original resolver orientation, signal polarity and repeated angle under the qualified bench setup. After service, validate the motor\/drive reference using the KEB commissioning method.\u003c\/p\u003e\n\u003cp\u003eCheck that the cyclic resolver position agrees across slow, controlled repeat observations. Verify original polarity and scaling.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"availability\"\u003e\u003ch2\u003eProduction and availability\u003c\/h2\u003e\n\u003cp\u003eRequest availability against the complete DL4 SG-L8 CF order, serial number and feedback label. SpareFaber offers installation, fault diagnosis and alignment assessment. Ask separately for part supply or replacement options.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eKEB COMBIVERT F6\/S6 as documented for the selected motor and drive rating. Supply both labels and the installed drive parameter set.\u003c\/p\u003e\n\u003cp\u003eSend the motor order, drive nameplate, feedback label and fault history to check the service scope and assembly revision.\u003c\/p\u003e\u003c\/section\u003e\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.kebamerica.com\/wp-content\/uploads\/2023\/09\/dl4_catalog.pdf\"\u003eKEB DL4 High Torque Series catalogue\u003c\/a\u003e. Standard feedback options, part number key and air \/ liquid cooled technical tables.\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.kebamerica.com\/wp-content\/uploads\/2023\/09\/dl4_manual.pdf\"\u003eKEB DL4 instructions for use\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection id=\"faq\"\u003e\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat should I send for an evaluation?\u003c\/summary\u003e\u003cp\u003eSend the complete DL4 SG-L8 CF order, feedback label, connectors at both ends, drive order and the original fault or alarm.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan I match the feedback from the motor frame?\u003c\/summary\u003e\u003cp\u003eUse the order information above, then compare the actual feedback label, signals, drawings and reference procedure.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eCan you check the motor at our site?\u003c\/summary\u003e\u003cp\u003eRequest a UAE site visit or bench evaluation. Share the location, equipment labels and what happened before the fault so the service team can confirm the appropriate scope.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\u003cdiv id=\"enquiry\"\u003e\n\u003ch2\u003eRequest service\u003c\/h2\u003e\n\u003cp\u003eSend the full motor and encoder IDs, drive model, connector pictures and fault history with your service enquiry. Include your location for an on-site visit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"KEB","offers":[{"title":"Default Title","offer_id":51311080472741,"sku":"TCG1995","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/keb-dl4-sg-l8-cf-resolver-technical-guide-cover.jpg?v=1795541245","url":"https:\/\/www.sparefaber.com\/products\/keb-dl4-sg-l8-cf-resolver-technical-guide","provider":"SpareFaber","version":"1.0","type":"link"}