{"product_id":"mitsubishi-csw26k-j5-encoder","title":"Mitsubishi Electric CSW26K J5 26-Bit Serial Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for CSW26K feedback diagnosis and installation checks, and send-in evaluation where the fitted device and test setup are confirmed.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Mitsubishi Electric CSW26K J5 26-Bit Serial Encoder technical guide\"\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Mitchell documents J5 testing and distinguishes removable CSW from built-in CBW.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Mitchell lists J5 run support. Confirm the fitted HK motor and firmware.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eMitsubishi Electric CSW26K J5 26-Bit Serial Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eIdentification and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCSW26K\u003c\/th\u003e\n\u003ctd\u003eRemovable 26-bit feedback identified by Mitchell. Match the encoder ID and motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCBW26K\u003c\/th\u003e\n\u003ctd\u003eBuilt-in type identified separately in the same article.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCSW26K INC\u003c\/th\u003e\n\u003ctd\u003eMitchell selection for the distinct incremental-use ID associated with HK-MT.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm current orderability and any successor for the exact ID with the manufacturer or motor OEM. The dated documentation identifies the configuration.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data for CSW26K\" tabindex=\"0\"\u003e\u003ctable\u003e\n\u003ccaption\u003eReference data for CSW26K\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition resolution\u003c\/th\u003e\n\u003ctd\u003e26 bits, or 67,108,864 counts per revolution in the documented J5 motor system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRetention\u003c\/th\u003e\n\u003ctd\u003eBatteryless absolute-position architecture in the applicable J5 configurations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal connection\u003c\/th\u003e\n\u003ctd\u003e10-pin DDK or hybrid connector, depending on HK motor build.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eIdentify the HK motor order and whether the encoder is removable or integrated. Use the service drawing for rotor attachment and cable clearance. Confirm the replacement procedure before disturbing the feedback assembly.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe J5 amplifier reads the feedback ID as well as position. Mitchell reports that the INC build has a different ID and the drive disregards its multiturn count. A bench reading alone cannot establish that the drive will use the same absolute mode.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eIdentify the motor-side connector before choosing the MR-J5 wiring figure. Mitchell illustrates a 10-pin DDK connection for listed HK-ST\/HK-RT builds and a hybrid connector for the specified HK-KT\/HK-MT\/HK-RT builds.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eTI-5732 applies to the documented DDK connection and TI-5772 to the documented hybrid. Confirm the OEM machine cable, motor order and amplifier separately. Identify any internal loom by the fitted assembly.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore inspection.\u003c\/strong\u003e Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition is readable but the drive reports the wrong feedback mode\u003c\/th\u003e\n\u003ctd\u003eCompare the exact ABS or INC ID and the drive’s configured mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThe expected test cable does not mate\u003c\/th\u003e\n\u003ctd\u003eCheck DDK versus hybrid and confirm the exact HK motor option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAxis reference changed after service\u003c\/th\u003e\n\u003ctd\u003eVerify the reference and commissioning steps in the applicable MR-J5 and machine manuals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eMELSERVO J5 motor options. Exact HK order open. Check the exact ID, drive and connector before applying an installation or test procedure.\u003c\/p\u003e\n\u003cp\u003eSeparate ABS and INC encoder IDs and match the fitted connector before selecting a bench profile.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord the motor and drive configuration, full encoder ID and original machine reference. Restore the reference using the approved machine procedure after installation. Treat feedback identity, angle verification and absolute position use as separate checks.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/22504530020251-Mitsubishi-Melservo-J5-Series\"\u003eMitsubishi J5 guide\u003c\/a\u003e. Overview and Rotary Motor Models. CSW26K, CBW26K and HK-MT INC.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/manual\/servo\/sh030314eng\/sh030314engm.pdf\"\u003eMitsubishi Electric MR-J5 rotary servo motor manual\u003c\/a\u003e. Motor selection, connection drawings, and the 26-bit feedback specification by series.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51127096737957,"sku":"TCG176","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/mitsubishi-csw26k-j5-encoder-service-guide.jpg?v=1794236254","url":"https:\/\/www.sparefaber.com\/products\/mitsubishi-csw26k-j5-encoder","provider":"SpareFaber","version":"1.0","type":"link"}