{"product_id":"mitsubishi-osa105s2a-servo-feedback","title":"Mitsubishi Electric OSA105S2A Servo Feedback Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for OSA105S2A installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Mitsubishi Electric OSA105S2A Servo Feedback Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell documents an OSA105-family bench readout. Confirm the S2A label, protocol and connector, compatible profile and exact test harness before using TI-5000JX. The TI-3000JX motor-run selection requires separate verification.\u003c\/p\u003e\n\u003ch2\u003eMitsubishi Electric OSA105S2A Servo Feedback Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eOSA105S2A\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOSA105S2A\u003c\/th\u003e\n\u003ctd\u003eFull marking reported by suppliers. Confirm the actual label, shaft and installed motor drawing.\u003c\/td\u003e\n\u003ctd\u003eMitsubishi documents OSA105-family high-speed serial. Exact S2A signal and connector scope pending.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOSA105\u003c\/th\u003e\n\u003ctd\u003eMitsubishi OEM family designation in MDS-C1-N documentation.\u003c\/td\u003e\n\u003ctd\u003eHigh-speed serial motor-end encoder in the compatibility table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOSA105-ET\u003c\/th\u003e\n\u003ctd\u003eSeparate entry in Mitsubishi's machine-end section.\u003c\/td\u003e\n\u003ctd\u003eConfirm installation role and supported drive, even where the family name is similar.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for OSA105S2A\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for OSA105S2A\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOEM family interface\u003c\/th\u003e\n\u003ctd\u003eHigh-speed serial at the motor end for OSA105 in Mitsubishi IB(NA)1501296. The table is at family scope.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReadout convention\u003c\/th\u003e\n\u003ctd\u003eMitchell distinguishes the OSA105 family’s serial count representation from how the drive or literature describes resolution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection and limits\u003c\/th\u003e\n\u003ctd\u003eS2A-specific supply, connector view and pin assignment need the OEM motor or encoder drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrive identification\u003c\/th\u003e\n\u003ctd\u003eRecord the exact MDS unit and supported feedback option before selecting the setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/www.mitsubishielectric.com\/dl\/fa\/document\/manual\/cnc\/ib1501296\/ib1501296engc.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003ePair the original motor tag with the full encoder marking. Check the mounting pilot, shaft or coupling, axial retention and lead routing on the OEM assembly. Retain the reference and observe the installed position before moving the rotor. Use the exact manual for torque and fit limits.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe documented OSA105 family sends position as a high-speed serial word. A drive can scale the data for its position display, so compare the actual receiver settings and the OEM definition of counts per turn. One supplier description calls the S2A incremental. Resolve the exact assembly from the motor drawing and use the Mitsubishi family table to guide that check.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eMitsubishi serial fixtures exist with different data-pair and connector arrangements. Identify the complete motor and drive before mapping supply, return, serial connections and shield. Use the exact connector drawing rather than extrapolating pin numbers from OSA104, OSA18 or the OSA105-ET machine-end version.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe Mitchell cable index has several Mitsubishi serial leads differentiated by connector. Obtain the matching OEM feedback cable number from the motor and MDS unit. The product guide needs the S2A connector and wiring drawing before a Mitchell test lead or internal harness can be assigned.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMDS reports feedback loss immediately\u003c\/th\u003e\n\u003ctd\u003eRecord the drive alarm and exact model, verify the selected motor-end encoder type, then inspect and test the isolated harness.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver count appears different from the catalogue\u003c\/th\u003e\n\u003ctd\u003eCompare the interface word, drive scaling and displayed units for the exact encoder family.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault started after substitution\u003c\/th\u003e\n\u003ctd\u003eCheck the original suffix, motor-end versus machine-end role, installed lead and reference parameters.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eThe MDS-C1-N compatibility table separates OSA105 motor-end from OSA105-ET machine-end roles. Establish the actual S2A motor and drive before applying the family table.\u003c\/p\u003e\n\u003cp\u003eFor a different Mitsubishi serial family, use the exact part and motor documentation. \u003ca href=\"\/products\/mitsubishi-osa18-hf-sp\"\u003eOSA18 technical guide\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSave the original drive settings and available encoder identity and reference data under the OEM procedure before replacement. Verify mounting, motor commutation and machine datum separately. A supported readout of the serial word is one check in commissioning.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitsubishielectric.com\/dl\/fa\/document\/manual\/cnc\/ib1501296\/ib1501296engc.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Mitsubishi IB(NA)1501296. Section 1.1.4 gives OSA105-family drive compatibility. S2A-specific limits and mounting require the original assembly document.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26664477076123-Mitsubishi-Motors-and-Serial-Encoders\"\u003eMitchell Mitsubishi serial encoder guide\u003c\/a\u003e. OSA105-family position readout and related serial types.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4404782857755-Mitsubishi-Serial-Connections-4-wire-or-2-wire-data\"\u003eMitchell serial connection note\u003c\/a\u003e. Application differences between two- and four-wire arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.viyork-tech.com\/mitsubishi-encoder-osa105s2a-product\/\"\u003eSupplier S2A identification lead\u003c\/a\u003e. Evidence of the observed suffix. Verify with the motor OEM before applying electrical or fit specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51125753708709,"sku":"TCG134","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/mitsubishi-osa105s2a-servo-feedback-service-guide.jpg?v=1794215502","url":"https:\/\/www.sparefaber.com\/products\/mitsubishi-osa105s2a-servo-feedback","provider":"SpareFaber","version":"1.0","type":"link"}