{"product_id":"mitsubishi-osa18-hf-sp","title":"Mitsubishi Electric OSA18 HF-SP Encoder  | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eHF-SP encoder alarm or a servo that trips after repair?\u003c\/strong\u003e SpareFaber can visit your UAE site to check the OSA18 application, MR-J3 diagnostics, motor connector and encoder cable. Ask about bench evaluation with the original motor and feedback assembly.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Mitsubishi Electric OSA18 HF-SP Encoder technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the full HF-SP model and serial, OSA18 marking and suffix, amplifier model, exact AL code and photos of the motor connector and cable markings. Note whether the fault occurs at power-up, at enable or while moving. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eMitchell documents \u003cstrong\u003eTI-5000JX\u003c\/strong\u003e testing for supported Mitsubishi serial encoders and describes why a replacement can report a different programmed ID from its base model. Verify the actual ID, Athena profile and lead for the OSA18 motor assembly before testing. The exact 191247 motor combination was not verified on the TI-3000JX. Where a run is supported, use the exact motor configuration and verify commutation on a secured, guarded fixture. \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26664477076123-Mitsubishi-Motors-and-Serial-Encoders\"\u003eMitchell Mitsubishi encoder test and ID notes\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26664785456539-Mitsubishi-Motors\"\u003eMitchell Mitsubishi motor run documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eMitsubishi Electric OSA18 HF-SP Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eRead the complete motor and encoder labels before ordering. Mitsubishi lists \u003cstrong\u003e191247\u003c\/strong\u003e for the spare named HF-SP52 up to 702(B) encoder OSA18. Match the actual motor code and serial to the service part, including any encoder suffix and brake or connector option.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"OSA18 identification and family boundaries\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eOSA18 identification and family boundaries\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eLabel \/ code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat the source verifies\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eUse it to\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e191247 · OSA18\u003c\/th\u003e\n\u003ctd\u003eMitsubishi European spare listing for HF-SP52 up to 702(B)\u003c\/td\u003e\n\u003ctd\u003eConfirm replacement by the actual motor and serial.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOSA17 \/ OSA14\u003c\/th\u003e\n\u003ctd\u003eRelated Mitsubishi serial examples in Mitchell’s guide. Some replacements are configured for a lower resolution.\u003c\/td\u003e\n\u003ctd\u003eConfirm the programmed ID and exact profile. The base name alone does not establish interchangeability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHF-SP52 \/ HF-SP52B\u003c\/th\u003e\n\u003ctd\u003eMotor order examples in the Mitsubishi J3 catalogue. B indicates the brake variant in the motor outlines.\u003c\/td\u003e\n\u003ctd\u003eSelect the exact cable and motor service drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/mitsubishi-electric-eshop.mee.com\/mee\/FA_IA\/en\/EUR\/Catalogue\/Servo\/Spare-Part\/HF-SP52-up-to-702(B)-ENCODER-OSA18\/p\/000000000000191247\"\u003eMitsubishi OSA18 service spare\u003c\/a\u003e · \u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/catalog\/servo\/l03017\/l03017g.pdf\"\u003eMitsubishi HF-SP motor catalogue (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26664477076123-Mitsubishi-Motors-and-Serial-Encoders\"\u003eMitchell model identification\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eMitsubishi’s European catalogue identifies OSA18 spare \u003cstrong\u003e191247\u003c\/strong\u003e. Mitsubishi labels the MR-J3 drive family discontinued. Production and availability of the exact OSA18 service assembly require confirmation by motor serial. Reviewed 7 November 2026. \u003ca href=\"https:\/\/mitsubishi-electric-eshop.mee.com\/mee\/FA_IA\/en\/EUR\/Catalogue\/Servo\/Spare-Part\/HF-SP52-up-to-702(B)-ENCODER-OSA18\/p\/000000000000191247\"\u003eMitsubishi spare part record\u003c\/a\u003e · \u003ca href=\"https:\/\/www.mitsubishielectric.com\/fa\/download\/search.page?kisyu=%2Fservo\u0026amp;mode=manual\"\u003eMitsubishi drive lifecycle and manuals\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"HF-SP \/ MR-J3 documented system data and exact-spare scope\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eHF-SP \/ MR-J3 documented system data and exact-spare scope\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue \/ source boundary\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback class\u003c\/th\u003e\n\u003ctd\u003eMitsubishi serial motor feedback for the approved HF-SP build.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSystem resolution\u003c\/th\u003e\n\u003ctd\u003eMELSERVO-J3 catalogue gives 262,144 positions per revolution for the documented motor system. Confirm the actual programmed encoder and motor combination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrive-side encoder supply\u003c\/th\u003e\n\u003ctd\u003eP5 and LG on the documented MR-J3-A CN2. The application drawing identifies the encoder power and return.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor connection\u003c\/th\u003e\n\u003ctd\u003eMitsubishi HF-SP outline identifies CM10-R10P for the documented external encoder connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical and environmental limits\u003c\/th\u003e\n\u003ctd\u003eUse the exact HF-SP motor outline and service drawing. The spare listing does not publish encoder-only fit, torque, supply tolerance or operating limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/catalog\/servo\/l03017\/l03017g.pdf\"\u003eMitsubishi J3 motor specifications and dimensions (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/manual\/servo\/sh030038\/sh030038l.pdf\"\u003eMitsubishi MR-J3-A signals and wiring (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe encoder is located in the motor’s rear feedback assembly and follows shaft rotation. Preserve the original seating, mechanical index and harness routing. Inspect the motor cover, connector mounting, signs of impact and bearing play. The HF-SP catalogue provides the motor outline and external connector. Use the exact serial-specific service drawing for internal rotor retention, stator seating, fasteners and alignment. A public motor outline cannot establish internal adjustment dimensions. \u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/catalog\/servo\/l03017\/l03017g.pdf\"\u003eHF-SP outlines and connector drawings (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe amplifier exchanges Mitsubishi serial feedback on the documented differential interface. It uses encoder position and status to control the motor. The system’s absolute option also depends on its documented backup circuit and reference setup. Check communication, mechanical feedback and position retention as separate functions. A different replacement profile can respond electrically and still be unsuitable for the motor.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"MR-J3-A CN2 drive side, 3M connector layout in SH-030038\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eMR-J3-A CN2 drive side, 3M connector layout in SH-030038\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eCN2 pin(s)\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMarking and role\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1 \/ 2\u003c\/th\u003e\n\u003ctd\u003eP5 \/ LG, encoder supply and return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3 \/ 4\u003c\/th\u003e\n\u003ctd\u003eMR \/ MRR, paired serial signals shown in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e7 \/ 8\u003c\/th\u003e\n\u003ctd\u003eMD \/ MDR, additional pair in the documented CN2 map. Connect only as the exact cable drawing specifies.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e9\u003c\/th\u003e\n\u003ctd\u003eBAT on the documented absolute wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse the manual view for the exact connector version. Mitsubishi also publishes the HF-SP motor connector outline. The CN2 numbers do not specify the motor connector or the OSA18 PCB. Keep other pins open or routed only as the applicable wiring diagram requires. \u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/manual\/servo\/sh030038\/sh030038l.pdf\"\u003eMR-J3-A CN2 drawings (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/dl.mitsubishielectric.co.jp\/dl\/fa\/document\/catalog\/servo\/l03127\/l03127enge.pdf\"\u003eJ3 and J4 connector differences (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/catalog\/servo\/l03017\/l03017g.pdf\"\u003eHF-SP motor connector outline (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Mitsubishi HF-SP compatible external cable and connector examples\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eMitsubishi HF-SP compatible external cable and connector examples\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePart number\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat it connects\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMR-J3ENSCBL5M-L\u003c\/th\u003e\n\u003ctd\u003e5 m standard bending life option for the documented HF-SP direct encoder connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMR-J3ENSCBL5M-H\u003c\/th\u003e\n\u003ctd\u003e5 m long bending life option. Confirm actual motor and amplifier.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMR-J3SCNS \/ MR-J3SCNSA\u003c\/th\u003e\n\u003ctd\u003eStraight \/ angled connector set options listed for supported HF-SP configurations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCM10-SP10S-M (D6)\u003c\/th\u003e\n\u003ctd\u003eDDK straight motor-side mating connector component in the MR-J3SCNS kit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eRead the cable suffix, including any vibration option. Match both ends, shield and absolute-position wiring. The in-motor OSA18 lead and PCB map require the exact service drawing or a confirmed replacement assembly. \u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/catalog\/servo\/l03017\/l03017g.pdf\"\u003eMitsubishi MELSERVO-J3 cable and connector ordering (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSecure the load and preserve the incoming position.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized. Include any absolute backup circuit in the safe test plan.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect.\u003c\/strong\u003e Check the CN2 latch and motor connector for bent or backed-out pins, oil, dirt, crushed wires, poor strain relief and a disturbed rear cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the isolated harness.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Compare the exact cable drawing before interpreting any omitted or bridged conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck power and alarm state.\u003c\/strong\u003e With an approved breakout fitted while off, a qualified technician can verify the P5\/LG voltage at the documented CN2. Use the drive manual and approved diagnostics to check communication and battery status. Read the exact alarm and detail code, including AL.16 or AL.20 where applicable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparate the possibilities.\u003c\/strong\u003e If the fault changes with cable movement, inspect contacts and flex points first. If a known-good matched cable and supply leave the same fault, check the installed encoder ID and the motor. If communication is healthy and torque trips began after replacement, check the approved alignment and motor setup.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eMitsubishi lists spare 191247 for the named HF-SP range and documents the HF-SP52(B) motor outline in its J3 catalogue. Use the specific amplifier compatibility table, complete model code and connector drawing. When migrating to J4, review Mitsubishi’s CN2 and cable differences. \u003ca href=\"https:\/\/mitsubishi-electric-eshop.mee.com\/mee\/FA_IA\/en\/EUR\/Catalogue\/Servo\/Spare-Part\/HF-SP52-up-to-702(B)-ENCODER-OSA18\/p\/000000000000191247\"\u003eMitsubishi spare applicability\u003c\/a\u003e · \u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/catalog\/servo\/l03017\/l03017g.pdf\"\u003eMitsubishi HF-SP application data (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/dl.mitsubishielectric.co.jp\/dl\/fa\/document\/catalog\/servo\/l03127\/l03127enge.pdf\"\u003eMitsubishi MR-J3 to MR-J4 transition (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord original drive settings and absolute machine position before removing the encoder. The motor’s commutation alignment and the machine’s absolute datum are separate. If the repair procedure calls for restoring data, verify the exact motor and compatible replacement, restore only the authorized values, then read back and verify direction, commutation and reference. Obtain the motor-specific service procedure for the internal offset. The OSA18 family label supplies no universal angle.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/mitsubishi-electric-eshop.mee.com\/mee\/FA_IA\/en\/EUR\/Catalogue\/Servo\/Spare-Part\/HF-SP52-up-to-702(B)-ENCODER-OSA18\/p\/000000000000191247\"\u003eMitsubishi Electric OSA18 191247 catalogue record\u003c\/a\u003e. Exact service spare and named motor range.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/catalog\/servo\/l03017\/l03017g.pdf\"\u003eMitsubishi MELSERVO-J3 catalogue (PDF)\u003c\/a\u003e. HF-SP outline, encoder connector and cable ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/manual\/servo\/sh030038\/sh030038l.pdf\"\u003eMitsubishi MR-J3-A instruction manual SH-030038 (PDF)\u003c\/a\u003e. CN2, alarms and absolute position setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/dl.mitsubishielectric.co.jp\/dl\/fa\/document\/catalog\/servo\/l03127\/l03127enge.pdf\"\u003eMitsubishi J3-to-J4 transition handbook (PDF)\u003c\/a\u003e. CN2 wiring and cable compatibility by drive series.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26664477076123-Mitsubishi-Motors-and-Serial-Encoders\"\u003eMitchell Mitsubishi serial encoder test reference\u003c\/a\u003e. Verify actual programmed ID and supported profile.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51117231407269,"sku":"TXG08","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/MitsubishiElectricOSA18HF-SPEncoder.jpg?v=1794145362","url":"https:\/\/www.sparefaber.com\/products\/mitsubishi-osa18-hf-sp","provider":"SpareFaber","version":"1.0","type":"link"}