{"product_id":"omron_tln5my1","title":"Omron TL-N5MY1 AC 2-wire, proximity sensor, 5mm Sensing, NO","description":"\u003cp\u003eRectangular Standard Proximity Sensor\u003c\/p\u003e\n\u003cp\u003eModel ; TL-N5MY1 2M *1\u003cbr\u003eAppearance:  25X25MM\u003cbr\u003esensing distance: 5mm\u003cbr\u003eOutput Configuration: AC 2Wire \u003cbr\u003e Operation mode ( NO) | Unshielded\u003c\/p\u003e\n\u003cp\u003eEasy installation, high-speed pulse generator, high-speed rotation control, and more.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003especifications; \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eModel : \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eTL-N5MY[] \u003c\/span\u003e\u003cspan\u003e TL-N5MY1 \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSensing distance \u003c\/strong\u003e : \u003cspan\u003e \u003c\/span\u003e5 mm ±10%\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSet distance :\u003c\/strong\u003e \u003cspan\u003e \u003c\/span\u003e0 to 4 mm\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eDifferential travel\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003e15% max. of sensing distance\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eDetectable object\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eFerrous metal (The sensing distance decreases with non-ferrous metal. Refer to\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : Engineering Data on Data Sheet.) \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003eStandard sensing object\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eIron, 30 × 30 × 1 mm\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eResponse frequency *1\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eE\/F Models: 500 Hz\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : Y Models: 10 Hz \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/Output_Circuit_for_model_TL-N5MY1_Operation_Mode-_NO_240x240.png?v=1788674011\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003ePower supply voltage *2\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eE\/F Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e(operating voltage range)\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eY Models: 100 to 220 VAC (90 to 250 VAC), 50\/60 Hz\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eCurrent consumption\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eE\/F Models: 8 mA max. at 12 VDC, 15 mA max. at 24 VDC\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eLeakage current\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eY Models: Refer to Engineering Data on Catalog.\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eControl\u003cspan\u003e \u003c\/span\u003eLoad current\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eE\/F Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eoutput\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eY Models: 10 to 100 mA\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/Timing_Chart_for_model_TL-N5MY1_Operation_Mode_NO.png?v=1788674032\" alt=\"\" width=\"205\" height=\"110\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eResidual voltage : E Models: 2 V max. (load current: 200 mA) \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : F Models: 1 V max. (load current: 200 mA) \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : Y Models: Refer to Engineering Data on Catalog. \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003eIndicators\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eE\/F Models: Detection indicator (red)\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : Y Models \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : D1 Type: Operation indicator (red), Setting indicator (green) \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : D2 Type: Operation indicator (red) \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003eOperation mode (with\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eE1\/F1\/Y1 Models: NO\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003esensing object approaching)\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eE2\/Y2 Models: NC\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : Refer to the timing charts under I\/O Circuit Diagrams onCatalog for details. \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003eProtection circuits\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eE Models: Reverse polarity protection, Surge suppressor\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : Y Models: Surge suppressor \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003eAmbient temperature range\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eOperating\/Storage: -25 to 70°C (with no icing or condensation)\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eAmbient humidity range\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eOperating\/Storage: 35% to 95% (with no condensation)\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eTemperature influence\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003e±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eVoltage influence\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eE\/F Models:\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : ±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : Y Models: \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : ±1% max. of sensing distance at rated voltage in rated voltage ±10% range \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003eInsulation resistance\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003e50 MΩ min. (at 500 VDC) between current-carrying parts and case\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eDielectric strength \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eE\/F Models: 1,000 VAC, 50\/60 Hz for 1 min between current-carrying parts and case\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : Y Models: 2,000 VAC, 50\/60 Hz for 1 min between current-carrying parts and case \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003eVibration resistance\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eDestruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e : directions \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/Mounting_dimensions_for_model_TL-N5MY1_Operation_Mode_NO.png?v=1788675209\" alt=\"\" width=\"493\" height=\"301\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eShock resistance \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eDestruction: 500 m\/s2 10 times each in X, Y, and Z directions\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eDegree of protection\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eIEC 60529 IP67, in-house standards: oil-resistant\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eConnection method :\u003c\/span\u003e \u003cspan\u003e \u003c\/span\u003ePre-wired Models (Standard cable length: 2 m)\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eWeight (packed state\u003c\/span\u003e)\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eApprox. 190 g\u003cspan\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eMaterials Case \u0026amp; Sensing surface\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e : \u003cspan\u003e \u003c\/span\u003eHeat-resistant ABS\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"OMRON","offers":[{"title":"Default Title","offer_id":48226174763173,"sku":"sen45","price":395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/Omron_TL-N5MY1_Proximity_Switch_4.jpg?v=1788629944","url":"https:\/\/www.sparefaber.com\/products\/omron_tln5my1","provider":"SpareFaber","version":"1.0","type":"link"}