{"product_id":"pepperl-fuchs-dvm58n-011agr0by-1213","title":"Pepperl+Fuchs DVM58N DeviceNet Multiturn Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for DVM58N installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Pepperl+Fuchs DVM58N DeviceNet Multiturn Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA DeviceNet scanner or approved interface can verify node startup and the count in a controlled fixture. Check the exact model configuration and network health before attributing a communication fault to the encoder. Mitchell support is unverified for this exact part.\u003c\/p\u003e\n\u003ch2\u003ePepperl+Fuchs DVM58N DeviceNet Multiturn Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eDVM58N-011AGR0BY-1213\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDVM58N-011AGR0BY-1213\u003c\/th\u003e\n\u003ctd\u003e10 mm × 20 mm solid shaft and clamp flange. Removable radial terminal cover.\u003c\/td\u003e\n\u003ctd\u003eDeviceNet with binary output, 12-bit turns and 13-bit angle. Y marks customized parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDVM58N-011AGR0BN-1213\u003c\/th\u003e\n\u003ctd\u003eRelated Ø10 × 20 mm clamping-flange DeviceNet build.\u003c\/td\u003e\n\u003ctd\u003eThe family ordering table calls N the unexpanded option. The BY version specifies customized settings. Compare the delivered parameters.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for DVM58N-011AGR0BY-1213\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for DVM58N-011AGR0BY-1213\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShaft and flange\u003c\/th\u003e\n\u003ctd\u003eØ10 × 20 mm solid shaft, clamping flange. Drawing 308150, page 1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition capacity\u003c\/th\u003e\n\u003ctd\u003e13 bits per turn and 12 bits for turn count, 25 bits total. Scaling may alter the engineering units.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e10–30 V DC. No-load maximum 230 mA at 10 V or 100 mA at 24 V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBus and enclosure\u003c\/th\u003e\n\u003ctd\u003eDeviceNet up to 500 kbit\/s, galvanically isolated interface. IP65 with correctly assembled cover.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePublished mechanical limits\u003c\/th\u003e\n\u003ctd\u003eMaximum 12,000 rpm. Shaft load limits 40 N axial and 110 N radial. Check combined load and application life separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/308150_eng.pdf?v=20220421160432\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the shaft, locating spigot and clamping flange dimensions on page 1. Couple to the machine with a correctly sized coupling. Verify alignment and avoid transferring machine thrust through the encoder. Preserve the original terminal cover settings and gasket condition before separating the cover.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe optical absolute sensing system tracks angle and turns. A DeviceNet host requests or maps the position using the device's profile. Polled operation and position scaling are described in the exact datasheet. The receiver must interpret the encoder's configured direction, resolution and preset before converting the position to machine units.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the labels in the removable housing cover, page 3. Compare with the wiring and shield drawing on page 5. Take an isolated photograph of the terminals and switch positions before removing a conductor.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"DVM58N-011AGR0BY-1213 DeviceNet terminals\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eDVM58N-011AGR0BY-1213 DeviceNet terminals\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eMark\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e+ \/ −\u003c\/th\u003e\n\u003ctd\u003eEncoder supply \/ return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGround symbol\u003c\/th\u003e\n\u003ctd\u003ePower supply ground connection shown in drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCG\u003c\/th\u003e\n\u003ctd\u003eCAN reference, on bus in and bus out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCL \/ CH\u003c\/th\u003e\n\u003ctd\u003eCAN low \/ CAN high, repeated for both bus connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eT\u003c\/th\u003e\n\u003ctd\u003eSwitch for internal 121 Ω end termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eUse the DeviceNet bus cable and gland specified by the machine designer. Confirm DeviceNet shield routing and whether the head is at the physical end of the trunk. The radial cover uses terminals and does not require a generic M23 loom. Document bus in and out before transferring them.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoth LEDs off\u003c\/th\u003e\n\u003ctd\u003eCheck the power terminals and supply. Isolate the harness to check conductor continuity and unwanted bonds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply present but no usable position\u003c\/th\u003e\n\u003ctd\u003eConfirm the configured unique node address, 125\/250\/500 kbit\/s switch setting, trunk termination and scanner configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStable data but wrong machine value\u003c\/th\u003e\n\u003ctd\u003eCompare raw position with known motion. Inspect coupling slip, configured code sequence, scaling and preset.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse on a DeviceNet-controlled machine axis with a matching scanner or gateway. Confirm exact EDS and scanner I\/O mapping with the installed PLC project. The datasheet documents the encoder and configuration attributes.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eBack up address, baud, count direction, resolution, total range and preset before replacing the Y-code encoder. At the OEM machine reference position, restore and verify its preset and count direction. The feedback encoder is a standalone measuring device. Establish servo commutation using the motor and drive procedure when the machine has a separate motor encoder.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/308150_eng.pdf?v=20220421160432\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/308150_ger.pdf\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/308150_eng.pdf?v=20220421160432#page=3\"\u003eConnection and configuration, page 3\u003c\/a\u003e. Terminal diagram, address, baud, termination and LEDs.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/files.pepperl-fuchs.com\/webcat\/navi\/productInfo\/pds\/308150_eng.pdf?v=20220421160432#page=4\"\u003eOrdering code and position attributes, page 4\u003c\/a\u003e. Decodes the shaft, output, resolution and Y option.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sparefaber.com\/cdn\/shop\/files\/Datasheet_Pepperl_Fuchs_MultiTurn_DeviceNet_Binary_8192x4096_DVM58N-011AGR0BN-1213.pdf?v=5918335994468697841\"\u003eDVM family ordering table for the N option\u003c\/a\u003e. See page 7 for the unexpanded option and mounting codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sparefaber.com\/products\/pepperl-fuchs-devicenet-dvm58n-011agr0bn-1213\"\u003eRelated DVM58N-011AGR0BN-1213 listing\u003c\/a\u003e. Compare the configuration before choosing this part.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118427144357,"sku":"TCG61","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/Pepperl_FuchsDVM58NDeviceNetMultiturnEncoder_2.jpg?v=1794133306","url":"https:\/\/www.sparefaber.com\/products\/pepperl-fuchs-dvm58n-011agr0by-1213","provider":"SpareFaber","version":"1.0","type":"link"}