{"product_id":"renishaw-tonic-t1030-15a","title":"Renishaw TONiC T1030-15A Optical Linear Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for TONiC T1030-15A installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Renishaw TONiC T1030-15A Optical Linear Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eEvaluate setup indication across travel and compare differential outputs on a qualified scope with the documented load. A spare Ti alone cannot establish readhead condition without the compatible scale and geometry. Confirm Mitchell support with the complete readhead and interface codes before selecting a tester.\u003c\/p\u003e\n\u003ch2\u003eRenishaw TONiC T1030-15A Optical Linear Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eT1030-15A\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eT1030-15A\u003c\/th\u003e\n\u003ctd\u003eOptical readhead for the compatible RTLC20\/RTLC20-S or RKLC20-S scale system. 1.5 m integral lead.\u003c\/td\u003e\n\u003ctd\u003eInterboard connection to compatible TONiC interface. Customer-selectable reference mark.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTi0000A00A\u003c\/th\u003e\n\u003ctd\u003eSeparate analogue interface between the readhead lead and controller.\u003c\/td\u003e\n\u003ctd\u003e15-way D-type analogue 1 Vpp output. An accessory to the readhead.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTi0004–Ti20KD\u003c\/th\u003e\n\u003ctd\u003eDigital Ti interface family. Read the exact code on the installed interface.\u003c\/td\u003e\n\u003ctd\u003eDigital differential output. Resolution and clocking depend on the interface code. Different D-type assignment from Ti0000.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for T1030-15A\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for T1030-15A\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReadhead body \/ lead\u003c\/th\u003e\n\u003ctd\u003e35 × 13.5 × 10 mm TONiC body. T1030-15A has a 1.5 m interboard lead.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eScale \/ principle\u003c\/th\u003e\n\u003ctd\u003eCompatible TONiC 20 µm optical scale and reference selector system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue example\u003c\/th\u003e\n\u003ctd\u003eT1030-15A with Ti0000A00A. Nominal 1 Vpp differential sine\/cosine. Supply 5 V ±10%, \u0026lt;100 mA for readhead with Ti0000.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl resolution\u003c\/th\u003e\n\u003ctd\u003eDetermined by the interpolation in the receiver or by the selected digital interface. Capture both codes on a service call.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/data-sheet-tonic-encoder-system--137201?userLanguage=en\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eRead the scale label before choosing the installation guide. On RTLC20-S, keep the readhead bracket flat, stiff and adjustable. Compare the drawing's optical centre line, ride height, yaw, pitch and roll against the actual carriage. Set clearance with the specified setup aid and confirm the setup LED over full travel. The scale, optic window and mounting faces need to be clean.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe optical readhead produces periodic incremental signals as it passes the scale. With Ti0000A00A, the controller interpolates the two differential sinusoids and counts full scale periods. The separately selected reference mark lets the controller establish a machine origin after power-up. A digital Ti interface performs interpolation before sending pulses to the controller.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThis map applies at the \u003cstrong\u003eTi0000 analogue 15-way D-type output\u003c\/strong\u003e. Use the connector face diagram in the datasheet. The integral readhead cable's interboard plug and digital Ti variants have separate assignments.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Ti0000 analogue output contacts\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eTi0000 analogue output contacts\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePin numbers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e+5 V \/ 0 V\u003c\/th\u003e\n\u003ctd\u003e4 and 5 \/ 12 and 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCosine V1 + \/ −\u003c\/th\u003e\n\u003ctd\u003e9 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSine V2 + \/ −\u003c\/th\u003e\n\u003ctd\u003e10 \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference V0 + \/ −\u003c\/th\u003e\n\u003ctd\u003e3 \/ 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLimit Vp \/ Vq\u003c\/th\u003e\n\u003ctd\u003e7 \/ 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSetup Vx \/ CAL\u003c\/th\u003e\n\u003ctd\u003e6 \/ 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter screen\u003c\/th\u003e\n\u003ctd\u003eD-type case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eFollow the data sheet's grounding drawing for the inner shield. Preserve the verified OEM screening arrangement at the machine.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe -15A assembly includes its readhead lead. Ti0000A00A is the confirmed analogue interface option. For the D-type-to-controller cable, verify the controller's sine\/cosine input pins, screen routing and signal pair terminations in its manual. The finished machine loom is OEM-specific.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSetup LED degrades at a repeatable point\u003c\/th\u003e\n\u003ctd\u003eCheck local dirt, scale damage, bracket flex and ride height through the same part of travel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGood setup LED, lost counts\u003c\/th\u003e\n\u003ctd\u003eCompare signals at the Ti output and controller input. Confirm analogue versus digital receiver and cable pin assignment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCounts move correctly, homing fails\u003c\/th\u003e\n\u003ctd\u003eCheck the reference selector's location, the reference output and the controller's homing configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eTypical applications include precision linear stages and machine axes. Confirm whether the controller receives direct analogue signals or the digital Ti interface outputs before changing the scale, readhead or interface.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eUse the appropriate scale installation guide to set geometry and run its calibration sequence. On the machine, re-establish the reference and verify the count direction and origin. The reference selector and controller offset determine the homing result. Servo motor commutation uses separate feedback.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/data-sheet-tonic-encoder-system--137201?userLanguage=en\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/store.renishaw.com\/en-GB\/product\/T1030-15A\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/media\/pdf\/en\/aa157195ba9343eaa781ccc14a475298.pdf\"\u003eT1x3x RTLC20-S installation guide\u003c\/a\u003e. Use the mounting, calibration and output connections sections.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/resourcecentre\/download\/installation-guide-tonic-t103x-rklc20-s-linear-encoder-system--145432?userLanguage=en\"\u003eT1x3x RKLC20-S installation guide\u003c\/a\u003e. Use when the installed scale is RKLC20-S.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.renishaw.com\/en\/tonic-downloads--37857\"\u003eRenishaw TONiC downloads\u003c\/a\u003e. Family manuals and selection documents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118422622373,"sku":"TCG59","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/RenishawTONiCT1030-15AOpticalLinearEncoder.jpg?v=1794142520","url":"https:\/\/www.sparefaber.com\/products\/renishaw-tonic-t1030-15a","provider":"SpareFaber","version":"1.0","type":"link"}