{"product_id":"rexroth-mke-n-p-indramat-digital-feedback","title":"Bosch Rexroth MKE N\/P Indramat Digital Motor Feedback | Technical Guide | Service Visit for Identification and Fault Diagnosis","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eRead the full motor order and protection marking first. An MKE encoder label may omit the protocol. Mitchell identifies the N\/P branch as legacy Indramat digital feedback.\u003c\/p\u003e\n\u003cp\u003eSpareFaber can help identify the MKE feedback option and review alarms and external cable evidence. Send the full motor label and protection marking. The matching Rexroth instructions govern enclosure work and repairs.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Bosch Rexroth MKE N\/P Indramat Digital Motor Feedback technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Mitchell documents the Indramat selection and memory test for N\/P. Scope service to approved equipment and procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Exact motor-run setup open.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e TI-5076 for the documented direct legacy encoder connection Module TI-5104.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eBosch Rexroth MKE N\/P Indramat Digital Motor Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMKE option N or P\u003c\/th\u003e\n\u003ctd\u003eLegacy Indramat digital encoder branch in Mitchell’s MKE option table. Confirm the complete motor order and protection marking.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMKE options B\/D or A\/C\u003c\/th\u003e\n\u003ctd\u003eSeparate EnDat or HIPERFACE versions. The motor order establishes which branch applies.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMKE options G\/K\u003c\/th\u003e\n\u003ctd\u003eDigital resolver branch with a different test workflow.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtocol in scope\u003c\/th\u003e\n\u003ctd\u003eLegacy Indramat digital I²C for the documented N\/P option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor connection\u003c\/th\u003e\n\u003ctd\u003eThe MKE example has internal terminal blocks inside the protected assembly. Obtain the matching Rexroth drawing and service scope.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpecialist test setup\u003c\/th\u003e\n\u003ctd\u003eMitchell documents TI-5076 with TI-5104 and the Indramat memory selection for N\/P. Apply the OEM service scope for the fitted motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe legacy digital link carries position and motor data for the drive. Similar labels can belong to different interfaces. Identify the option before interpreting a missing serial response or selecting a substitute.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the exact MKE type code, protection marking and Rexroth drawing to identify the frame and feedback assembly. The matched manual governs sealing and enclosure work. Rexroth’s Gen2 instructions assign encoder replacement to Rexroth service.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eUse the exact motor and terminal drawing for the external connection and drive-side checks. Internal pin mapping and testing belong to the applicable approved service process. Mitchell’s direct test cable reference is for the documented feedback option.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eRecord the machine cable and cable-entry details from the motor nameplate and drawings. Select an OEM-approved replacement for the exact motor. TI-5076 and TI-5104 describe test equipment, separate from the installed lead.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eKeep the certified enclosure closed for field checks. Use the nameplate, accessible external wiring and drive diagnostics under the site isolation procedure. Refer enclosure repair or encoder replacement to Rexroth service under the matching instructions.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo feedback after a motor or drive change\u003c\/th\u003e\n\u003ctd\u003eCompare the full MKE option code and drive setup. Have the documented external path checked before enclosure work.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntermittent alarm on the installed machine\u003c\/th\u003e\n\u003ctd\u003eRecord the fault conditions and inspect accessible external cable supports and connections under site isolation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEncoder assembly suspected\u003c\/th\u003e\n\u003ctd\u003eSend the complete type and protection marking to the service provider. Rexroth instructions govern internal inspection and replacement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003ePreserve the incoming motor identity, alarm and reference information. Have Rexroth service follow the exact procedure for internal feedback or memory work under the applicable motor instructions.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eBosch Rexroth MKE, feedback option N or P\u003c\/p\u003e\n\u003cp\u003eIdentify the real protocol by motor order. Flameproof enclosure service requires the OEM-approved scope and procedure.\u003c\/p\u003e\n\u003ch3\u003eRelated SpareFaber guides\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/bosch-rexroth-mkd071b-061-k\"\u003eBosch Rexroth Indramat MKD071B-061 K Servo Feedback \u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/28522290257563-Bosch-Rexroth-Indramat-MKE-Motors\"\u003eBosch\/Rexroth\/Indramat MKE Motors\u003c\/a\u003e. MKE Motor Model Breakdown. Legacy N\/P options, direct lead and distinct EnDat\/HIPERFACE branches.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.cmafh.com\/images\/Master%20PDFs\/BRC\/Motors\/MKE\/Rexroth%20MKE%20Project%20Planning%20Manual%20R911297663_06.pdf\"\u003eRexroth MKE Gen2 project planning manual R911297663\u003c\/a\u003e. Rexroth-authored manual hosted by a distributor. Check the applicable generation, motor connection and repair section.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the complete MKE motor order, protection marking, drive model, alarm and evidence from accessible external cables. We can help identify the feedback option and the next diagnostic step.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the complete MKE motor order, protection marking, drive model, alarm and evidence from accessible external cables. We can help identify the feedback option and the next diagnostic step.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51127643570341,"sku":"TCG204","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/rexroth-mke-n-p-indramat-digital-feedback-service-guide.jpg?v=1794243090","url":"https:\/\/www.sparefaber.com\/products\/rexroth-mke-n-p-indramat-digital-feedback","provider":"SpareFaber","version":"1.0","type":"link"}