{"product_id":"rls-aksim-2-mb049dcc19bdnp00","title":"RLS AksIM-2 MB049 BiSS-C Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for AksIM-2 MB049 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"RLS AksIM-2 MB049 BiSS-C Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse a matched BiSS-C controller or RLS-supported interface for position, register and CRC checks. Log faults against shaft angle to distinguish readhead spacing from a harness issue. Exact Mitchell compatibility for this readhead and motor assembly requires confirmation.\u003c\/p\u003e\n\u003ch2\u003eRLS AksIM-2 MB049 BiSS-C Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eMB049DCC19BDNP00\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMB049DCC19BDNP00\u003c\/th\u003e\n\u003ctd\u003eMB049 board readhead for an MRA049 ring, N connector and documented P-option build.\u003c\/td\u003e\n\u003ctd\u003eBiSS-C bidirectional with register access, 19-bit singleturn.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMB049DCC19MDNP00\u003c\/th\u003e\n\u003ctd\u003eRelated P-option readhead for MRA049.\u003c\/td\u003e\n\u003ctd\u003e19-bit singleturn plus 16-bit multiturn counter. Check settings and power-off behavior.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMB029DCC18MFNP00\u003c\/th\u003e\n\u003ctd\u003eRelated P-option readhead for a different ring size.\u003c\/td\u003e\n\u003ctd\u003eDifferent resolution and geometry. Verify the matching ring and controller.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for MB049DCC19BDNP00\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for MB049DCC19BDNP00\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference build\u003c\/th\u003e\n\u003ctd\u003eMB049 readhead, MRA049-compatible ring, DCC BiSS-C and 19B singleturn resolution code.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e4.5–5.5 V at the readhead connector. MBD01 specifies supply rise time under 20 ms.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eDifferential MA and SLO. Use the exact BiSS-C controller frame and timing from MBD01.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpecial environment\u003c\/th\u003e\n\u003ctd\u003eP-option is listed for pressure and vacuum applications with distinct timing requirements. Use the manufacturer conditions for the complete assembly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation dimensions\u003c\/th\u003e\n\u003ctd\u003eUse the MRA049 ring drawing and corresponding MB049 readhead drawing for concentricity, mounting and ride height.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.rls.si\/eng\/fileuploader\/download\/download\/?d=1\u0026amp;id=267\u0026amp;title=Data+sheet%253A+AksIM-2%25E2%2584%25A2+off-axis+rotary+absolute+magnetic+encoder+%2528MBD01%2529\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe magnetic ring and readhead are separate. Verify the ring's full code and mounting datum, then compare ride height around the full circumference against MBD01. A ring can be centered but still have an uneven gap due to tilt or shaft runout. Inspect the readhead bracket, ring retention and nearby magnetic or metallic contamination before moving the sensor.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe BiSS-C master provides the MA clock pair. The encoder replies on SLO with position, status and CRC, and the DCC configuration supports register access. Diagnose a valid position and status warning separately from a CRC or timeout. Use the P-option clock and timing guidance where the operating environment requires it.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThe N-option low-profile 8-pin connector is shown in MBD01 Electrical connections. Use the numbered face and correct mating part. These are readhead contacts, not D-sub cable contacts.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"RLS N-option connector\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eRLS N-option connector\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePins\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1 \/ 2\u003c\/th\u003e\n\u003ctd\u003e5 V \/ 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3 \/ 4\u003c\/th\u003e\n\u003ctd\u003eExternal isolated temperature sensor connections if applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e5 \/ 6\u003c\/th\u003e\n\u003ctd\u003eMA+ \/ MA−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e7 \/ 8\u003c\/th\u003e\n\u003ctd\u003eSLO+ \/ SLO−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eFollow the specified cable, termination and shield routing. Verify any receiver-side D-sub against the matching cable assembly table.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eMBD01 lists N-option cable assemblies including ACC015 and ACC061. Match the chosen length and flying-lead or connector end in the assembly table before ordering. For the exact readhead keep the clock and data pairs together and use the approved grounding arrangement. An OEM motor or joint loom requires the builder's own drawing.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCRC or timeout at all positions\u003c\/th\u003e\n\u003ctd\u003eCheck supply rise and voltage at the head, MA and SLO pair integrity, controller frame and termination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSignal warnings at the same shaft angle\u003c\/th\u003e\n\u003ctd\u003eInspect ride height over a full turn and check ring seating and runout.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReadout smooth but axis zero is wrong\u003c\/th\u003e\n\u003ctd\u003eVerify the reference stored in the controller and the physical ring orientation before setting a new datum.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eRLS documents off-axis magnetic feedback for compact assemblies and lists this exact P-option model in its special-environment section. Match the ring, bearings, readhead electronics and drive configuration to the machine. Verify environmental qualification for the assembled system.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eAlign the ring and readhead mechanically, verify the gap and diagnostic status over a turn, then confirm direction and machine datum. For a motor joint, use its own electrical reference procedure. Preserve any OEM settings before replacing the head or ring.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rls.si\/eng\/fileuploader\/download\/download\/?d=1\u0026amp;id=267\u0026amp;title=Data+sheet%253A+AksIM-2%25E2%2584%25A2+off-axis+rotary+absolute+magnetic+encoder+%2528MBD01%2529\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rls.si\/eng\/aksim-2-off-axis-rotary-absolute-encoder\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rls.si\/eng\/fileuploader\/download\/download\/?d=1\u0026amp;id=267\u0026amp;title=Data+sheet%253A+AksIM-2%25E2%2584%25A2+off-axis+rotary+absolute+magnetic+encoder+%2528MBD01%2529\"\u003eRLS MBD01 AksIM-2 datasheet\u003c\/a\u003e. See Electrical connections, special-environment variants, BiSS and Cable assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.rls.si\/eng\/aksim-2-redundant-encoder\"\u003eRLS separate redundant family\u003c\/a\u003e. Compare the device identity and connector before using a redundant model's documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118412857509,"sku":"TCG57","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/RLSAksIM-2MB049BiSS-CEncoder.jpg?v=1794142831","url":"https:\/\/www.sparefaber.com\/products\/rls-aksim-2-mb049dcc19bdnp00","provider":"SpareFaber","version":"1.0","type":"link"}