{"product_id":"sanyo-denki-e07b151103","title":"Sanyo Denki E07B151103 ABSOSYN Serial and Incremental Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for E07B151103 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Sanyo Denki E07B151103 ABSOSYN Serial and Incremental Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eWe separate an ABSOSYN data or backup problem from an A\/B count fault and inspect the 17-pin harness before replacing the encoder. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eFor TI-5000JX, Mitchell documents the E07B151103 selection and comparing the serial position with the A\/B count. For TI-3000JX, Mitchell documents the E07B15 four-pole selection for 61BM220BBAF0 using TI-5056. Confirm the exact motor, keyed harness, power connection and approved fixture before a run.\u003c\/p\u003e\n\u003ch2\u003eSanyo Denki E07B151103 ABSOSYN Serial and Incremental Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eE07B151103\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eE07B151103\u003c\/th\u003e\n\u003ctd\u003eMitchell identifies it in 61BM220BBAF0. The mechanical drawing for the fitted unit is still needed.\u003c\/td\u003e\n\u003ctd\u003e15-bit within-turn absolute position, bounded turn count and incremental A\/B. TI-5056 is documented.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eE07B151306\u003c\/th\u003e\n\u003ctd\u003eSeparate motor\/encoder build. Verify the fitted code.\u003c\/td\u003e\n\u003ctd\u003eDifferent turn format and an incremental Z output in Mitchell's reference.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eE10B171103\u003c\/th\u003e\n\u003ctd\u003eDifferent motor example in the same legacy cable family.\u003c\/td\u003e\n\u003ctd\u003eHigher-resolution serial version. Select by exact label.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe legacy application is documented by Mitchell. Confirm Sanyo Denki service availability and the exact encoder order before sourcing.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for E07B151103\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for E07B151103\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWithin-turn serial count\u003c\/th\u003e\n\u003ctd\u003e15 bits, 32,768 positions per turn, per Mitchell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial turn count\u003c\/th\u003e\n\u003ctd\u003eMitchell describes 0 through 1,799 revolutions for E07B151103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncremental track\u003c\/th\u003e\n\u003ctd\u003eA\/B, 32,768 counts per turn in the documented setup. This variant has no Z channel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExact documented motor\u003c\/th\u003e\n\u003ctd\u003e61BM220BBAF0 in the Mitchell Sanyo Denki run guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest harness\u003c\/th\u003e\n\u003ctd\u003eTI-5056, 17-pin MS according to the Mitchell index\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eConfirm 61BM220BBAF0 and the encoder suffix before disturbing the mounting. With the load secured and isolated, record the as-found locating surfaces, retention, housing position and cable routing. Inspect for looseness, shaft play and wear on the mounting surfaces. Obtain the original service drawing for the exact fit and tightening specification.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eABSOSYN serial data contains the within-turn count and turns. A separate incremental A\/B channel reports movement. Mitchell uses the serial angle as a reference to compare A\/B counts because this variant has no Z pulse. This helps distinguish a bad pulse channel from a lost serial response.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eIdentify the 17-pin MS connector from the exact motor and the TI-5056 sheet. The serial pair, incremental tracks, operating supply and battery circuit must be traced individually. Use the published motor-side and tester-side drawings for cavity numbers and view. Supply and backup limits for the fitted unit need the OEM sheet.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eMitchell’s index names TI-5056 for E07B151103 and E10B171103, and the run guide cites it for 61BM220BBAF0. Identify the original motor's internal encoder lead and machine cable separately. Confirm the stamped key and bulkhead numbering before terminating any replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial is stable but A\/B disagrees\u003c\/th\u003e\n\u003ctd\u003eVerify the incremental pair path and counts using the documented serial reference. Account for direction and the full turn.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eA\/B responds but absolute read fails\u003c\/th\u003e\n\u003ctd\u003eCheck serial pair continuity, receiver profile, loaded supply and connector condition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBackup warning after long storage\u003c\/th\u003e\n\u003ctd\u003eRecord the alarms and controller history. Mitchell describes a service reset for this exact encoder. Preserve any available reference and use the OEM backup and reset process.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback shifts following motor repair\u003c\/th\u003e\n\u003ctd\u003eCheck mounting, rotor reference and the exact motor’s phase arrangement. Confirm the drive’s settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eMitchell lists E07B151103 in Sanyo Denki 61BM220BBAF0. The other ABSOSYN models have separate data formats and motor combinations, even when the test cable is shared. Check the drive model and original motor ID.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eCapture the installed mechanical position and drive reference. Mitchell documents a specific TI-3000JX commissioning profile for 61BM220BBAF0. Use the OEM procedure and the exact motor phase and pole data to evaluate the commutation relationship. Preserve the original backup data before applying a reset.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26693556590107-Sanyo-Denki-Motors-and-Serial-Encoders\"\u003eMitchell Sanyo Denki bench guide\u003c\/a\u003e. E07B151103 frame, A\/B check and backup alarm notes.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26696124839963-Sanyo-Denki-Motors\"\u003eMitchell Sanyo Denki motor run guide\u003c\/a\u003e. E07B15 selection and documented 61BM220BBAF0 example.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\"\u003eMitchell manufacturer cable index\u003c\/a\u003e. 17-pin TI-5056 cable reference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese references describe the application and test route. The OEM encoder datasheet is still needed.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51124701462693,"sku":"TCG121","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/sanyo-denki-e07b151103-service-guide.jpg?v=1794210239","url":"https:\/\/www.sparefaber.com\/products\/sanyo-denki-e07b151103","provider":"SpareFaber","version":"1.0","type":"link"}