{"product_id":"sew-dfy-resolver-servo-feedback","title":"SEW-EURODRIVE DFY Resolver Motor Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eOn an SEW DFY, identify the resolver and the connection style before testing. Mitchell shows a separate terminal-box diagram for DFY71 through DFY112 and a resolver plug drawing.\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE on-site fault diagnosis, installation and alignment checks for the documented feedback. Send the fitted labels and alarm details to arrange a visit or a send-in evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"SEW-EURODRIVE DFY Resolver Motor Feedback technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Resolver checks on the TI-5000JX using the approved excitation and the fitting TI-5908 plug setup or a documented terminal-board breakout.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Verify the DFY order, polarity and matching drive fixture before any powered motor test.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e TI-5908 on the Mitchell DFY resolver plug; terminal box requires its own verified breakout.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eSEW-EURODRIVE DFY Resolver Motor Feedback technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDFY71–DFY112 with terminal box\u003c\/th\u003e\n\u003ctd\u003eUse the terminal-board drawing and its marked circuit designations. Read the motor order and suffix from the plate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDFY with resolver plug\u003c\/th\u003e\n\u003ctd\u003eMitchell names TI-5908 for the illustrated resolver plug. Match the contact count and keying before connecting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDFY absolute encoder option\u003c\/th\u003e\n\u003ctd\u003eA separate feedback branch is also illustrated. Use its own drawing and test method if that is what the motor order calls for.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeedback principle\u003c\/th\u003e\n\u003ctd\u003ePassive resolver with excitation, sine and cosine winding circuits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePlug setup\u003c\/th\u003e\n\u003ctd\u003e12-contact M23 on the illustrated TI-5908 branch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTerminal-box setup\u003c\/th\u003e\n\u003ctd\u003eUse the motor-specific resolver terminal diagram. Preserve identification of thermal protection and feedback circuits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe drive excites the resolver and derives electrical angle from its two return signals. A missing excitation path can make both returns disappear. A swapped pair can keep the angle reading smooth while changing its direction or phase.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eRecord the installed rotor position and the stator locating arrangement before disturbance. Use the complete DFY motor order and its rear assembly drawing for seating depth, fasteners and fit.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eOpen the DFY section of the linked Mitchell guide and select either its Resolver Connection drawing under Terminal Box or the separate drawing under Plug Connector. Compare the excitation and each return pair as a circuit. Keep the thermal pair and shield independent according to that view.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eTI-5908 is the test lead for the illustrated plug branch. Identify the terminal strip or factory pigtail from the exact motor order to source an internal harness. Obtain the installed cable drawing and connector keying for a machine-side replacement.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eA resolver is passive. Check isolated winding continuity against the matching drawing. Use the specified AC excitation on the approved test fixture for a signal check.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoth sine and cosine returns are absent\u003c\/th\u003e\n\u003ctd\u003eVerify the excitation circuit, supply from the approved fixture and cable path before condemning the resolver.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOnly one return drops out\u003c\/th\u003e\n\u003ctd\u003eIsolate the harness and measure continuity for the affected pair against the correct terminal or plug drawing. Inspect connector contact tension and contamination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAngle tracks but the motor runs roughly\u003c\/th\u003e\n\u003ctd\u003eCheck the fitted feedback option, winding polarity, resolver rotor fixing and commutation reference.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003ePreserve the original rotor-to-stator relationship. Use the matched SEW motor documentation and reference convention before a specialist measures alignment or restores operation.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eSEW DFY71–DFY112 terminal-box branch and documented DFY resolver plug branch\u003c\/p\u003e\n\u003cp\u003eConfirm the exact terminal or plug branch, excitation and transformation ratio for the fitted motor.\u003c\/p\u003e\n\u003ch3\u003eRelated SpareFaber guides\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/sew-cfm-as1h-hiperface-feedback\"\u003eSEW-EURODRIVE CFM AS1H HIPERFACE Multiturn Motor Feedback\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/27282690417947-SEW-Servo-Motors\"\u003eSEW Servo Motors\u003c\/a\u003e. DFY Series, resolver connections\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/article_attachments\/27286421425947\"\u003eSEW DFY71–DFY112 terminal strip resolver drawing\u003c\/a\u003e. OEM terminal-strip view reproduced in Mitchell’s DFY section.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/article_attachments\/27286804291739\"\u003eSEW DFY plug resolver drawing\u003c\/a\u003e. Illustrated plug branch and view for the resolver and thermal circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51127940645029,"sku":"TCG209","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/sew-dfy-resolver-servo-feedback-service-guide.jpg?v=1794245196","url":"https:\/\/www.sparefaber.com\/products\/sew-dfy-resolver-servo-feedback","provider":"SpareFaber","version":"1.0","type":"link"}